MICROSEMI MM158

2830 S. Fairview St.
Santa Ana, CA 92704
PH: (714) 979-8220
FAX: (714) 966-5256
Features
MM158
PRELIMINARY
• Designed for use with NiH battery cells on spacecraft
• Thermally activated non-dissipative permanent battery bypass
• Charge/discharge diodes are replaced by a permanent
low resistance short to bypass cell after open failure
• Compact, rugged construction offers weight and cost savings
• Can modify leads, available in different lengths
• Radiation tolerant to 300 Mrad total dose
• Discrete diodes screened and qualified per Microsemi PS11.50
• Multiple shorting points for redundant short activation
DISCHARGE: 200 A
CHARGE: 50 A
SHORT: 400A
BATTERY CELL
BYPASS/SHORTING
MODULE
Maximum Ratings @ 25°C (unless otherwise specified)
PART NUMBER
Discharge Current
Charge Current
Non-Rep Peak Surge Current (discharge)
Non-Repetitive Peak Surge Current (charge)
Operating and Storage Junction Temperature Range
Thermal resistance, junction to lead, discharge,
measured at lead adjacent to cover
Thermal resistance, junction to lead, charge,
measured at lead adjacent to cover
SYMBOL
MAX.
UNIT
ID
IC
IDSM
ICSM
Tj
Tstg
RΘ jLD
200
50
1000
350
-55 to +175
Amps
Amps
Amps
Amps
°C
0.5
°C/W
RΘ jLC
1.0
°C/W
Mechanical Outline
Datasheet# MSC0945.PDF
MM158
MSC0945.PDF
PRELIMINARY
Electrical Parameters, DISCHARGE circuit @ 25°C (unless otherwise specified)
DESCRIPTION
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
SYMBOL
VD1
VD2
VD3
VD4
VD5
VD6
VD7
CONDITIONS
IF= 10 A
IF= 50 A
IF= 100 A
IF= 200 A
IF= 400 A
IF= 200 A, TA= -55°C
IF= 200 A, TA= 125°C
MIN
TYP.
780
845
875
905
1100
985
790
MAX
830
900
940
975
1070
865
UNIT
mV
mV
mV
mV
mV
mV
mV
note: see MSARS200S200L data sheet for individual characteristics
Electrical Parameters, CHARGE circuit @ 25°C (unless otherwise specified)
DESCRIPTION
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
Forward Voltage, note 1
SYMBOL
VC1
VC2
VC3
VC4
VC5
VC6
VC7
VC8
VC9
VC10
CONDITIONS
IF= 10 mA
IF= 50 mA
IF= 100 mA
IF= 500 mA
IF= 5 A
IF= 10 A
IF= 25 A
IF= 50 A
IF= 25 A, TA= -55°C
IF= 25 A, TA= 125°C
MIN
TYP.
MAX
UNIT
1.85
-
1.72
1.9
2.0
2.15
2.43
2.5
2.6
2.75
2.9
2.3
2.1
2.52
2.65
2.8
2.95
-
V
V
V
V
V
V
V
V
V
V
note: see MSARS50S20Y data sheet for individual characteristics
Electrical Parameters, after cell fails open @ full temperature range
DESCRIPTION
SYMBOL
Shorted Current
Shorted Current (pulse)
Resistance
Shorted Cycling
Ishort
IPshort
Rshort
Cshort
Shorting Time
Notes
(1)
Pulse test, t ≤ 300 µs, duty cycle δ≤ 2%
tshort
CONDITIONS
t=dc
t=300ms
End to end of leads
Discharge=250A
Charge=50A
t=2 hrs min
at full load
MIN
TYP.
MAX
400
1000
250
300
50,000
TBD
UNIT
A
A
uΩ
cycles
secs