TOTAL-POWER TPS80-31

TOTAL POWER INT.
PPS80
SWITCHING
80W U CHANNEL
POWER
SUPPLIES
TPS80 SWITCHING
MODE
80WMODE
U BRACKET
POWER
SUPPLY
KEY FEATURES
*Universal input
*Built-in EMI filter
*Optional±12VDC/±24VDC/±48VDC input
*Optional cover
APPLICATIONS
*Telecommunications/Business machines
*Computer peripherals/Medical instruments
*Test & industrial equipments
ELECTRICAL SPECIFICATIONS
EMI & EMC
INPUT
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2,
-3 , -4 , -5 , -6 and -11
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------35A typical, Cold start @25℃,115VAC
*Efficiency------------65% ~80% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----80W with 30 CFM forced air
(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit
protection
*Overvoltage
protection ------------Main out put 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5 % per inquiry)
Power Derating Curve
80W
30 CFM Forced Air Cooling
60W
Output
Power 40W
(Watts) 20W
Natural
Convection
Cooling
40W
30W
0W
0
10
20
30
40
50
60
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A) (COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to 50℃ambient; derate each output at 2.5% per
degree from 50℃to 70℃
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85℃
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25℃ambient
conditions
70
Ambient Temperature( ° C)
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail: [email protected] http://www.total-power.com
-1-
TOTAL POWER
TPS80
MODEL
SWITCHING MODE 80W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
TPS80-10
+5V
±10% Typical
16A
20A
0A
±3%
±1%
100W Typical
TPS80-11
+12V
±10% Typical
6.6A
8.3A
0A
±3%
±1%
100W Typical
TPS80-12
+15V
6.6A
0A
±3%
±1%
100W Typical
+24V
±10% Typical
±10% Typical
5.3A
TPS80-13
3.3A
4.1A
0A
±1%
100W Typical
TPS80-14
+48V
±10% Typical
1.7A
2.1A
0A
±3%
±3%
±1%
100W Typical
TPS80-15
+36V
±10% Typical
2.2A
2.8A
0A
±3%
±1%
100W Typical
TPS80-17
+3.3V
±10% Typical
24A
26.3A
2.4A
±5%
±1.5%
100W Typical
DUAL OUTPUT MODEL SELECTION CHART
TPS80-20
TPS80-21
TPS80-22
TPS80-23
TPS80-24
TPS80-25
TPS80-26
TPS80-27Y
TPS80-28
TPS80-29
+5 V
±10% Typical
8A
10A
0.8A
±5%
±1%
+12V
Fixed
4A
5A
0.4A
±5%
±1%
+5 V
±10% Typical
8A
10A
0.8A
±5%
±1%
+24V
Fixed
1.7A
2.1A
0.17A
±1%
±1%
±1%
+5 V
±10% Typical
8A
10A
0.8A
±5%
±5%
-5V
Fixed
8A
10A
0.8A
±10%
+12V
±10% Typical
3.3A
4.1A
0.33A
±5%
±1%
-12 V
Fixed
3.3A
4.1A
0.33A
±10%
±1%
+15 V
±10% Typical
2.7A
3.4A
0.27A
±5%
±1%
-15 V
Fixed
2.7A
3.4A
0.27A
±10%
±1%
+3.3V
±10% Typical
10A
12.5A
1A
Fixed
4A
5A
0.4A
±5%
±5%
±1.5%
+12 V
+12V
±10% Typical
4A
5A
0.4A
±5%
±1%
+24V
Fixed
1.3A
1.6A
0.13A
±10%
±1%
±1%
+5V
±10% Typical
8A
10.4A
0.8A
±5%
±1%
+15V
Fixed
3.2A
4A
0.32A
±10%
±1%
+12.5V
±10% Typical
4.5A
5.6A
0.45A
±5%
±1%
+16V
Fixed
1.5A
1.8A
0.15A
±10%
±1%
+3.3V
±10% Typical
16A
20A
1.6A
±5%
±1.5%
+5V
Fixed
6A
7.5A
0.6A
±5%
±1%
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
TPS80-30
TPS80-31
TPS80-32
TPS80-33
TPS80-34
TPS80-35
TPS80-36
TPS80-37
+ 5V
±10% Typical
8A
10A
0.8A
±5%
±1%
+12V
Fixed
5A
6.3A
0.5A
±5%
±1%
- 5V
Fixed
1A
1.3A
0.1A
±10%
±1%
±1%
+ 5V
±10% Typical
8A
10A
0.8A
±5%
+12V
Fixed
2.9A
3.6A
0.29A
±5%
±1%
-12V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
+ 5V
±10% Typical
8A
10A
0.8A
±5%
±1%
+15V
Fixed
2.2A
2.8A
0.22A
±5%
±1%
-15V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
+ 5V
±10% Typical
10A
12.5A
1A
±5%
±1%
+15V
Fixed
1.6A
2A
0.16A
±5%
±1%
-5 V
Fixed
1A
1.3A
0.1A
±10%
±1%
+ 5V
±10% Typical
10A
12.5A
1A
±5%
±1%
+15V
Fixed
1.6A
2A
0.16A
±5%
±1%
-12V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
+5V
±10% Typical
7A
8.8A
0.7A
±5%
±1%
+24V
Fixed
1.6A
2A
0.16A
±5%
±1%
-12V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
+ 5V
±10% Typical
7A
8.8A
0.7A
±5%
±1%
+12V
Fixed
3.2A
4A
0.32A
±5%
±1%
-12V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
±1%
+ 5V
±10% Typical
7A
8.8A
0.7A
±5%
+12V
Fixed
2.8A
3.5A
0.28A
±5%
±1%
+24V
Fixed
0.5A
0.6A
0.05A
±10%
±1%
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail: [email protected] http://www.total-power.com
-2-
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
TOTAL POWER
TPS80
MODEL
SWITCHING MODE 80W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
TRIPLE OUTPUT MODEL SELECTION CHART
TPS80-38
TPS80-39
+15V
±10% Typical
2A
2.5A
0.2A
±5%
±1%
-15V
Fixed
2A
2.5A
0.2A
±10%
±1%
+5V
Fixed
4A
5A
0.4A
±10%
±1%
+12V
±10% Typical
1.5A
1.8A
0.15A
±5%
±1%
-12V
Fixed
1.5A
1.8A
0.15A
±5%
±1%
+28V
Fixed
1.6A
2A
0.16A
±10%
±1%
100W Typical
100W Typical
QUAD OUTPUT MODEL SELECTION CHART
TPS80-40
TPS80-41
TPS80-42
TPS80-43
TPS80-44
TPS80-45Y
TPS80-46Y
TPS80-47Y
TPS80-48Y
TPS80-49Y
+ 5V
±10% Typical
8A
10A
0.8A
±5%
±1%
+12V
Fixed
2.6A
3.3A
0.26A
±5%
±1%
- 12V
0.5A
0.6A
0.05A
±10%
±1%
-5 V
Fixed
Fixed
0.5A
0.6A
0.05A
±10%
±1%
+ 5V
±10% Typical
8A
10A
0.8A
±5%
±1%
+12V
Fixed
2.2A
2.8A
0.22A
±5%
±1%
-5V
Fixed
0.8A
1A
0.08A
±10%
±1%
- 12V
Fixed
±10% Typical
0.8A
1A
0.08A
±10%
±1%
+ 5V
8A
10A
0.8A
±5%
±1%
+12V
Fixed
1.3A
1.6A
0.13A
±5%
±1%
-15V
0.8A
1A
0.08A
±10%
±1%
+15V
Fixed
Fixed
0.8A
1A
0.08A
±10%
±1%
+ 5V
±10% Typical
4.5A
5.6A
0.45A
±5%
±1%
+12V
Fixed
2A
2.5A
0.2A
±5%
±1%
- 12V
Fixed
0.8A
1A
0.08A
±10%
±1%
+15V
Fixed
±10% Typical
1.6A
2A
0.16A
±10%
±1%
+ 5V
4.5A
5.6A
0.45A
±5%
±1%
+12V
Fixed
0.8A
1A
0.08A
±5%
±1%
- 12V
Fixed
0.8A
1A
0.08A
±10%
±1%
+48V
Fixed
±10% Typical
0.8A
1A
0.08A
±10%
±1%
+ 5V
8A
10.4A
0.8A
±5%
±1%
+12V
Fixed
0.8A
1.04A
0.08A
±5%
±1%
- 12V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+24V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+5V
±10% Typical
8A
10.4A
0.8A
±5%
±1%
+15V
Fixed
0.8A
1.04A
0.08A
±5%
±1%
-15V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+48V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+5V
±10% Typical
4A
5.2A
0.4A
±5%
±1%
+12V
Fixed
1.4A
1.8A
0.14A
±5%
±1%
-12V
Fixed
1.4A
1.8A
0.14A
±10%
±1%
+36V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+5V
±10% Typical
8A
10.4A
0.8A
±5%
±1%
+15V
Fixed
0.8A
1.04A
0.08A
±5%
±1%
-15V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+24V
Fixed
0.8A
1.04A
0.08A
±10%
±1%
+3.3V
±10% Typical
7A
15A
0.7A
±5%
±1.5%
+5V
Fixed
5A
6.2A
0.5A
±5%
±1%
+12V
Fixed
2.5A
6.2A
0.25A
±10%
±1%
-5V
Fixed
1A
3.7A
0.1A
±10%
±1%
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail: [email protected] http://www.total-power.com
-3-
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
100W Typical
TOTAL POWER
TPS80
MODEL
SWITCHING MODE 80W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line, 0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail: [email protected] http://www.total-power.com
-4-