TOTAL-POWER TPS350-48Y

TOTAL POWER INT.
SWITCHING MODE 350W U CHANNEL POWER SUPPLIES
TPS350 SWITCHING MODE 350W U CHANNEL POWER SUPPLY
PPS350
KEY FEATURES
*Universal input/ Built-in EMI filter
*Optional remote sense on main output
*Optional constant current charger
*Optional Power Good signal/ AC fail signal
*Optional remote On/ Off signal/ Optional cover
*Optional±12VDC/±24VDC/±48VDC input
*Optional constant current change (for single output)
APPLICATIONS
*Telecommunications/ Medical instruments
*Computer peripherals/ Business machines
*Test, Burn-In & industrial equipments
ELECTRICAL SPECIFICATIONS
EMI & EMC
INPUT
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE,EN 61000-3-2 (Class A)(Optional) and –3;
*Input range-----------90~264 VAC, auto ranging
*Frequency------------47~63Hz
*Inrush current--------45A typical,. Cold start @25℃,115VAC
*Efficiency------------65%~85% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power---- 350W with 30 CFM forced air
(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5% per inquiry)
Power Derating Curve
350W
30 CFM Forced Air Cooling
200W
175W
Output
Power 150W
(Watts) 100W
Natural
Convection
Cooling
100W
50W
0
10
20
30
40
50
60
EN 61000-4-2,-3,-4,-5,-6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 6 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A) (COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to 50℃ambient; derate each output at 2.5% per
degree from 50℃to 70℃
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85℃
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25℃ambient
conditions
70
Ambient Temperature( ° C)
TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395
E-mail:[email protected] http://www.total-power.com
-1-
TOTAL POWER
MODEL
TPS350
SWITCHING MODE 350W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
TPS350-10
+5V
±10% Typical
60 A
TPS350-11
+12V
±10% Typical
29.2A
69A
0A
±3%
±1%
400W Typical
33.6A
0A
±3%
±1%
400W Typical
TPS350-12
+15V
±10% Typical
23.3A
26.8A
0A
±3%
±1%
400W Typical
TPS350-13
+24V
±10% Typical
14.6A
16.8A
0A
±3%
±1%
400W Typical
TPS350-14
+48V
±10% Typical
7.3A
8.4A
0A
±3%
±1%
400W Typical
TPS350-15
+36V
±10% Typical
9.7A
11.2A
0A
±3%
±1%
400W Typical
TPS350-16
+56V
±10% Typical
6.25A
7.2A
0A
±3%
±1%
400W Typical
TPS350-17
+18V
±10% Typical
19.4A
22.3A
0A
±3%
±1%
400W Typical
TPS350-18
+3.3V
±10% Typical
60 A
69A
0A
±5%
±1.5%
400W Typical
54.6A
18.2A
45.5A
9.1A
54.6A
54.6A
19.5A
19.5A
15.6A
15.6A
62.4A
19.5A
20.8A
10.4A
26A
32.5A
58.5A
58.5A
4.2A
1.4A
3.7A
0.7A
4.2A
4.2A
1.5A
1.5A
1.2A
1.2A
4.8A
1.5A
1.6A
0.8A
2A
2.5A
4.5A
4.5A
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1.5%
±1%
±1%
±1%
±1%
±1%
±1.5%
±1%
±1%
DUAL OUTPUT MODEL SELECTION CHART
TPS350-20Y
TPS350-21Y
TPS350-22Y
TPS350-23Y
TPS350-24Y
TPS350-25Y
TPS350-26Y
TPS350-27Y
TPS350-28Y
+5 V
+12V
+5 V
+24V
+5 V
-5V
+12V
- 12 V
+15 V
- 15 V
+3.3V
+12 V
+ 12V
+ 24V
+ 12V
+5V
+ 3.3V
+5V
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
±10% Typical
±5% Typical
42A
14A
37A
7A
42A
42A
15A
15A
12A
12A
48A
15A
16A
8A
20A
25A
45A
45A
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
TPS350-30
TPS350-31
TPS350-32
TPS350-33Y
TPS350-34Y
TPS350-35
TPS350-36
TPS350-37
TPS350-38Y
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
+12V
Fixed
14A
16.1A
1.4A
±5%
±1%
-5V
Fixed
3.5A
4A
0.35A
±10%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
12A
13.8A
1.2A
±5%
±1%
- 12V
Fixed
3.5A
4A
0.35A
±10%
±1%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
+15V
Fixed
10A
11.5A
1A
±5%
±1%
-15V
Fixed
3.5A
4A
0.35A
±10%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+15V
Fixed
11A
9.2A
1.1A
±5%
±1%
-5V
Fixed
3.5A
4A
0.35A
±10%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+15V
Fixed
9A
9.2A
0.9A
±5%
±1%
-12V
Fixed
3.5A
4A
0.35A
±10%
±1%
+5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+24V
Fixed
7.2A
8.3A
0.72A
±5%
±1%
-12V
Fixed
3.5A
4A
0.35A
±10%
±1%
±1%
+ 5V
±10% Typical
30A
34.5A
3A
±5%
+12V
Fixed
15A
17.3A
1.5A
±5%
±1%
- 12V
Fixed
5A
5.8A
0.5A
±10%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
12A
13.8A
1.2A
±5%
±1%
+24V
Fixed
3.5A
4A
0.35A
±10%
±1%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
+24V
Fixed
2A
6.9A
0.2 A
±5%
±1%
+48V
Fixed
3.5A
4A
0.35A
±10%
±1%
TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395
E-mail:[email protected] http://www.total-power.com
-2-
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
TOTAL POWER
MODEL
PPS350
SWITCHING MODE 350W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
VOLTAGE
RANGE
CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
TRIPLE OUTPUT MODEL SELECTION CHART
TPS350-39
+3.3V
±10% Typical
35A
40.3A
3.5A
±5%
±1.5%
+5V
Fixed
20A
23A
2A
±5%
±1%
+12V
Fixed
7A
8A
0.7A
±10%
±1%
400W Typical
QUAD OUTPUT MODEL SELECTION CHART
TPS350-40
TPS350-41
TPS350-42
TPS350-43
TPS350-44
TPS350-45
TPS350-46
TPS350-47Y
TPS350-48Y
TPS350-49
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
12A
13.8A
1.2A
±5%
±1%
-5V
Fixed
3.5A
4A
0.35A
±10%
±1%
- 12V
±5% Typical
2A
2.3A
0.2A
±5%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
10A
11.5A
1A
±5%
±1%
-5V
Fixed
4A
4.6A
0.4A
±10%
±1%
- 12V
±5% Typical
3A
3.5A
0.3A
±5%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
7A
8.1A
0.7A
±5%
±1%
+15V
Fixed
3A
4.5A
0.3A
±10%
±1%
- 15V
±5% Typical
3A
3.5A
0.3A
±5%
±1%
+ 5V
±10% Typical
25A
28.8A
2.5A
±5%
±1%
+12V
Fixed
4A
4.6A
0.4A
±5%
±1%
- 12V
Fixed
2.5A
2.9A
0.25A
±10%
±1%
+24V
±5% Typical
6.5A
7.5A
0.65A
±5%
±1%
+ 5V
±10% Typical
25A
28.8A
2.5A
±5%
±1%
+12V
Fixed
4A
4.6A
0.4A
±5%
±1%
- 12V
Fixed
3A
3.5A
0.3A
±10%
±1%
+48V
±5% Typical
4A
4.6A
0.4A
±5%
±1%
+5V
±10% Typical
25A
28.8A
2.5A
±5%
±1%
+12V
Fixed
11A
12.7A
1.1A
±5%
±1%
-12V
Fixed
2.5A
2.9A
0.25A
±10%
±1%
+24V
±5% Typical
3.5A
4A
0.35A
±5%
±1%
+ 5V
±10% Typical
35A
40.3A
3.5A
±5%
±1%
+12V
Fixed
3A
3.5A
0.3A
±5%
±1%
-5V
Fixed
6A
6.9A
0.6A
±10%
±1%
+48V
±5% Typical
2.5A
2.9A
0.25A
±5%
±1%
+ 5V
±10% Typical
30A
34.5A
3A
±5%
±1%
+15V
Fixed
1.5A
4A
0.15A
±5%
±1%
- 15V
Fixed
1.5A
4A
0.15A
±10%
±1%
+48V
±5% Typical
4A
4.6A
0.4A
±5%
±1%
+ 5V
±10% Typical
25 A
28.8A
2.5A
±5%
±1%
+24V
Fixed
+48V
±5% Typical
4A
7.5A
0.2A
0.4A
±5%
±10%
±1%
Fixed
5.8A
5.2A
0.2A
- 12V
2A
2A
+3.3V
±10% Typical
35A
40.3A
3.5A
+5V
Fixed
20A
23A
+12V
Fixed
6A
6.9A
±1%
±5%
±1%
±5%
±1.5%
2A
±5%
±1%
0.6A
±10%
±1%
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
400W Typical
±5% Typical
±5%
±1%
- 12V
6A
6.9A
0.6A
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line, 0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.
TOTAL POWER, INC. TEL:877-646-0900 FAX:978-453-7395
E-mail:[email protected] http://www.total-power.com
-3-