MA-COM 36AYC10B

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
3-phase WYE RFI Power Line Filters for High Noise Applications
AYC Series
UL Recognized*
150AYC10B
AYC Series
Specifications
• For 3-phase, four wire, WYE applications
Maximum leakage current each Line to Ground:
120 VAC 60Hz
• Very high attenuation
• Low leakage current
• Ideal for EMC troubleshooting and refurbishing in
the field
• Touch safe terminals provide easy connections
and prevent inadvertent contact for safety in the
most demanding applications
Ordering Information
150 AYC 10 B -95
Terminal Block Option
-95 – 95mm terminal block
available on 150A only
Omit for standard terminals
Filter Type
B – Single stage
Input / Output Style
10 – Terminal block
16A
25 & 36A
63A
80, 100 & 150A
180, 200A
62 mA
68 mA
74 mA
74 mA
111 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Line to Neutral:
277 VAC 50Hz
106
118
128
129
192
mA
mA
mA
mA
mA
1850 VDC
1850 VDC
1450 VDC
Rated Voltage (max):
Phase to Phase:
Phase to Ground:
480 VAC
277 VAC
Operating Frequency:
50/60 Hz
Rated Current:
16 to 200A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Electrical Schematic
AYC Series
Current Rating
16, 25, 36, 63, 80, 110,
150, 180 or 200A
Available Part Numbers
16AYC10B
25AYC10B
36AYC10B
63AYC10B
80AYC10B
110AYC10B
150AYC10B
150AYC10B-95
180AYC10B
200AYC10B
A
LINE
LOAD
A
B
B
C
C
N
N
GND
GND
*All except 200AYC10B
108
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
3-phase WYE RFI Filters for High Noise Applications (continued)
AYC Series
Case Styles
16, 25, 36, 63AYC10B
Case Dimensions
Part No.
E
A
80, 110, 150AYC10B / -95
B D
C
D
E














































Terminal
Ground
16AYC10B
Line / Load
C
Ground
25AYC10B
Line / Load
Ground
180, 200AYC10B
36AYC10B
Line / Load
Ground
B D
63AYC10B
Line / Load
80, 110,
150AYC10B
E
E
A
C
2
Terminals
Part No.
E
A














Three Phase Filters
C
B




25AYC10B


36AYC10B


63AYC10B


80, 110 &

150AYC10B

150AYC10B-95


180AYC10B

200AYC10B
16AYC10B
B D
A

Ground
Line / Load
150AYC10B-95 Ground
180AYC10B
Line / Load
200AYC10B
Size
Torque max.
lbf-in [N-m]
M5
26.58 [3.0]
4mm²
7.08 [0.8]
terminal block
M5
26.58 [3.0]
6mm²
15.93 [1.8]
terminal block
M5
26.58 [3.0]
10mm²
15.93 [1.8]
terminal block
M6
53.1 [6.0]
16mm²
20.35 [2.3]
terminal block
M10
177.0 [20.0]
50mm²
70.80 [8.0]
terminal block
M10
177.0 [20.0]
95mm²
177.0 [20.0]
terminal block
109
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
3-phase WYE RFI Filters for High Noise Applications
(continued)
AYC Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
16AYC10B
25AYC10B
36AYC10B
63AYC10B
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
0
10
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
80AYC10B
110AYC10B
150AYC10B
180, 200AYC10B
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
0
10
0.01
0.1
1
0
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)

 








 









































































































































































110
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com