POWER-SYSTEMS PS-DA0253-124S

DC-AC INVERTER UNIT
PS-DA0253-124(S) (8 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Sharp: LQ104S1DG21 and LQ121S1LW01
APPLICABLE LCD:
10 to 15 inches dual lamp type
Lamp Voltage 466 Vrms
Lamp Current 2 x 6.0 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc)
FEATURES :
Input Voltage: 9.6 ~ 14.4 Vdc
Current Feedback Circuit
High Efficiency
Low noise with voltage resonant circuit
Regulated output current
RoHS compliant (S)
Coating on request
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-10°C ~ +65°C
-30°C ~ +85°C
95 %RH max
153 x 22 x 10 mm
Pin1
Pin1
Unit : mm
Weight :40 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0790
SM04(4.0)B-BHS-1-TB
Note
1,6 m m
Molex or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1, 16th May 2007
DC-AC INVERTER UNIT
PS-DA0253-124(S) (8 W DUAL OUTPUTS)
Input side CN1:
Pin No.
CN 1-1+2
CN 1-3+4
Symbols
Vin
GND
CN 1-5
Vrm t
CN 1-6
CN 1-7
N.C.
Vbr
(PRELIMINARY INFORMATION)
Output side CN2
Pin No.
Symbols
Vhigh
CN 2-1
Vhigh
CN 2-2
N.C.
CN 2-3
Vlow
CN 2-4
Ratings
9.6 ~ 14.4 Vdc
0 ~ 0.4 = OFF
/ 2.5 ~ Vin = ON
0 ~ 2.5 Vdc
Ratings
466 Vrm s (6.0 m Arm s )
466 Vrm s (6.0 m Arm s )
(GND)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F
Vopen
Ts d
Note 1 :
Vin (V)
Vbr (V)
9.6~14.4
9.6~14.4
9.6~14.4
9.6~14.4
10.8
9.6~14.4
0.0
2.5
0.0
0.0
0.0
0.0
Specification
Tu (°C)
-10
-10
-10
-10
-10
-10
~ +65
~ +65
~ +65
~ +65
~ +65
~ +65
Min.
Typ.
Max.
5.5
1.5
35
1.500
-
6.0
2.0
0.75
40
1.700
1.0
6.5
2.5
1.0
45
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
s ec
Duty 100%
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Open circuit on all lamps for more than 3 seconds, will shut the inverter down.
Note 2 :
TEST CIRCUIT :
F
Vin
9.6 ~ 14.4 V
Iin
A
1000:1
PROBE
F
Vopen
V
~
CN1-1
CN1-2
V
SW 1
Operation of unit
a
Operation
b
Non operation
CN1-3
CN2-1
CN1-4
Vrmt
0.4 / 2.5 Vdc
CN2-2
a
V
b
SW3
T1
RL2
SW1
RL1
CN1-5
CN2-3
N.C.
CL2
A
CL1
A
~
Iout ~
Iout1
2
SW4
N.C.
CN1-6
CN2-4
CN1-7
Vbr
0 ~ 2.5 Vdc
V
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.1, 16th May 2007