ETRON EM6A9320BIA

EtronTech
EM6A9320BIA
4M x 32 bit DDR Synchronous DRAM (SDRAM)
Etron Confidential
Preliminary (Rev 1.7 Nov. /2009)
Features
Overview
• Fast clock rate: 200/250 MHz
• Differential Clock CK & CK input
The EM6A9320 DDR SDRAM is a high-speed
CMOS double data rate synchronous DRAM
containing 128 Mbits. It is internally configured as a
quad 1M x 32 DRAM with a synchronous interface (all
signals are registered on the positive edge of the
clock signal, CK). Data outputs occur at both rising
edges of CK and CK . Read and write accesses to the
SDRAM are burst oriented; accesses start at a
selected location and continue for a programmed
number of locations in a programmed sequence.
• 4 Bi-directional DQS. Data transactions on both
edges of DQS (1DQS / Byte)
• DLL aligns DQ and DQS transitions
• Edge aligned data & DQS output
• Center aligned data & DQS input
• 4 internal banks, 1M x 32-bit for each bank
• Programmable mode and extended mode registers
- CAS Latency: 3
- Burst length: 2, 4, 8
- Burst Type: Sequential & Interleave
• All inputs except DQ’s & DM are at the positive
edge of the system clock
• 4 individual DM control for write masking only
• Auto Refresh and Self Refresh
• 4096 refresh cycles / 32ms
• Power supplies: VDD & VDDQ = 2.5V ± 5%
• Interface: SSTL_2 I/O compatible
• Package: 144-ball LFBGA
-Pb Free and Halogen Free
Accesses begin with the registration of a
BankActivate command, which is then followed by a
Read or Write command.
The EM6A9320 provides programmable Read or
Write burst lengths of 2, 4, 8. An auto precharge
function may be enabled to provide a self-timed row
precharge that is initiated at the end of the burst
sequence.The refresh functions, either Auto or Self
Refresh are easy to use.
In addition, EM6A9320 features programmable
DLL option. By having a programmable mode register
and extended mode register, the system can choose
the most suitable modes to maximize its performance.
These devices are well suited for applications
requiring high memory bandwidth, result in a device
particularly well suited to high performance main
memory and graphics applications.
Table1. Ordering Information
Part Number
Clock Frequency
Data Rate
EM6A9320BIA-4H
250MHz
500Mbps/pin
EM6A9320BIA-5H
200MHz
400Mbps/pin
BI: indicates LFBGA package
A: indicates generation code
H: indicates Pb Free and Halogen Free for LFBGA Packag
Power Supply
VDD 2.5V, VDDQ 2.5V
VDD 2.5V, VDDQ 2.5V
Package
LFBGA
LFBGA
Etron Technology, Inc.
No. 6, Technology Rd. V, Hsinchu Science Park, Hsinchu, Taiwan 30078, R.O.C.
TEL: (886)-3-5782345
FAX: (886)-3-5778671
Etron Technology, Inc. reserves the right to change products or specification without notice.
EtronTech
EM6A9320BIA
Figure 1. Pin Assignment (LFBGA 144Ball Top View)
1
2
3
4
5
6
7
8
9
10
11
12
A
DQS0
DM0
VSSQ
DQ3
DQ2
DQ0
DQ31
DQ29
DQ28
VSSQ
DM3
DQS3
B
DQ4
VDDQ
NC
VDDQ
DQ1
VDDQ
VDDQ
DQ30
VDDQ
NC
VDDQ
DQ27
C
DQ6
DQ5
VSSQ
VSSQ
VSSQ
VDD
VDD
VSSQ
VSSQ
VSSQ
DQ26
DQ25
D
DQ7
VDDQ
VDD
VSS
VSSQ
VSS
VSS
VSSQ
VSS
VDD
VDDQ
DQ24
E
DQ17
DQ16
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ15
DQ14
F
DQ19
DQ18
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ13
DQ12
G
DQS2
DM2
NC
VSSQ
VSS
VSS
VSS
VSS
VSSQ
NC
DM1
DQS1
H
DQ21
DQ20
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ11
DQ10
J
DQ22
DQ23
VDDQ
VSSQ
VSS
VSS
VSS
VSS
VSSQ
VDDQ
DQ9
DQ8
K
CAS
WE
VDD
VSS
A10
VDD
VDD
NC
VSS
VDD
NC
NC
L
RAS
NC
NC
BA1
A2
A11
A9
A5
NC
CK
CK
NC
M
CS
NC
BA0
A0
A1
A3
A4
A6
A7
A8
CKE
VREF
Table 2. Pin Assignment by Name (LFBGA 144Ball)
Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location Symbol Location
A0
M4
DQ6
C1
DQ24 D12
CK
L10 VDDQ B6
VSS
E5
VSS
J7
VSSQ G4
A1
M5
DQ7
D1
DQ25 C12
L11 VDDQ B7
VSS
E6
VSS
J8
VSSQ G9
CK
A2
L5
DQ8
J12 DQ26 C11
CKE M11 VDDQ B9
VSS
E7
VSS
K4 VSSQ H4
A3
M6
DQ9
J11 DQ27 B12
M1 VDDQ B11
VSS
E8
VSS
K9 VSSQ H9
CS
A4
M7
DQ10
H12
DQ28
A9
RAS
L1
VDDQ
D2
VSS
F5
VSSQ
A3
VSSQ
J4
A5
L8
DQ11
H11
DQ29
A8
CAS
K1
VDDQ
D11
VSS
F6
VSSQ
A10
VSSQ
J9
A6
A7
A8/AP
A9
A10
A11
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
M8
M9
M10
L7
K5
L6
A6
B5
A5
A4
B1
C2
DQ12
DQ13
DQ14
DQ15
DQ16
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
F12
F11
E12
E11
E2
E1
F2
F1
H2
H1
J1
J2
DQ30
DQ31
DQS0
DQS1
DQS2
DQS3
DM0
DM1
DM2
DM3
BA0
BA1
B8
A7
A1
G12
G1
A12
A2
G11
G2
A11
M3
L4
WE
VREF
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDD
VDDQ
VDDQ
K2
M12
C6
C7
D3
D10
K3
K6
K7
K10
B2
B4
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VDDQ
VSS
VSS
VSS
VSS
E3
E10
F3
F10
H3
H10
J3
J10
D4
D6
D7
D9
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
F7
F8
G5
G6
G7
G8
H5
H6
H7
H8
J5
J6
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
VSSQ
C3
C4
C5
C8
C9
C10
D5
D8
E4
E9
F4
F9
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
B3
B10
G3
G10
K8
K11
K12
L2
L3
L9
L12
M2
Etron Confidential
2
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 2. Block Diagram
DLL
CLOCK
BUFFER
Row
Decoder
CKE
Column Decoder
CS
RAS
CAS
WE
COMMAND
DECODER
A8/AP
COLUMN
COUNTER
DQS0~3
DQ0
MODE
REGISTER
Column Decoder
ADDRESS
BUFFER
REFRESH
COUNTER
DATA
STROBE
BUFFER
4096 x 256 x 32
CELL ARRAY
(BANK #2)
Column Decoder
DQ
Buffer
~
DQ31
DM0~3
Etron Confidential
4096 x 256 x 32
CELL ARRAY
(BANK #1)
Row
Decoder
A9
A10
A11
BA0
BA1
CONTROL
SIGNAL
GENERATOR
Row
Decoder
~
A0
4096 x 256 x 32
CELL ARRAY
(BANK #0)
Row
Decoder
CK
CK
3
4096 x 256 x 32
CELL ARRAY
(BANK #3)
Column Decoder
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Pin Descriptions
Table 3. Pin Details of EM6A9320
Symbol
CK, CK
Type
Input
CKE
Input
BA0, BA1
Input
A0-A11
Input
CS
Input
RAS
Input
Row Address Strobe: The RAS signal defines the operation commands in
conjunction with the CAS and /WE signals and is latched at the positive edges of CK.
When RAS and CS are asserted "LOW" and CAS is asserted "HIGH" either the
BankActivate command or the Precharge command is selected by the WE signal.
When the WE is asserted "HIGH," the BankActivate command is selected and the
bank designated by BA is turned on to the active state. When the WE is asserted
"LOW," the Precharge command is selected and the bank designated by BA is
switched to the idle state after the precharge operation.
CAS
Input
Column Address Strobe: The CAS signal defines the operation commands in
conjunction with the RAS and /WE signals and is latched at the positive edges of CK.
When /RAS is held "HIGH" and CS is asserted "LOW" the column access is started
by asserting CAS "LOW" Then, the Read or Write command is selected by asserting
WE "HIGH " or “LOW".
WE
Input
DQS0-DQS3
Input /
Output
DM0 - DM3
Input
DQ0 - DQ31
Input /
Output
Write Enable: The WE signal defines the operation commands in conjunction with
the RAS and CAS signals and is latched at the positive edges of CK. The WE input
is used to select the BankActivate or Precharge command and Read or Write
command.
Bidirectional Data Strobe: The DQSx signals are mapped to the following data
bytes: DQS0 to DQ0-DQ7, DQS1 to DQ8-DQ15, DQS2 to DQ16-DQ23, and DQS3 to
DQ24-DQ31.
Data Input Mask: DM0-DM3 are byte specific. Input data is masked when DM is
sampled HIGH during a write cycle. DM3 masks DQ31-DQ24, DM2 masks DQ23DQ16, DM1 masks DQ15-DQ8, and DM0 masks DQ7-DQ0.
Data I/O: The DQ0-DQ31 input and output data are synchronized with the positive
edges of CK and CK . The I/Os are byte-maskable during Writes.
VDD
VSS
Supply
Supply
Etron Confidential
Description
Differential Clock: CK, CK are driven by the system clock. All SDRAM input
commands are sampled on the positive edge of CK. Both CK and CK increment the
internal burst counter and controls the output registers.
Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CK signal. If CKE
goes low synchronously with clock, the internal clock is suspended from the next
clock cycle and the state of output and burst address is frozen as long as the CKE
remains low. When all banks are in the idle state, deactivating the clock controls the
entry to the Power Down and Self Refresh modes.
Bank Activate: BA0 and BA1 define to which bank the BankActivate, Read, Write, or
BankPrecharge command is being applied. They also define which Mode Register or
Extended Mode Register is loaded during a Mode Register Set command.
Address Inputs: A0-A11 are sampled during the Bank Activate command (row
address A0-A11) and Read/Write command (column address A0-A7 with A8 defining
Auto Precharge) to select one location out of the 1M available in the respective bank.
During a Precharge command, A8 is sampled to determine if all banks are to be
precharged (A8 = HIGH). The address inputs also provide the op-code during a Mode
Register Set or Extended Mode Register Set command.
Chip Select: CS enables (sampled LOW) and disables (sampled HIGH) the
command decoder. All commands are masked when CS is sampled HIGH. CS
provides for external bank selection on systems with multiple banks. It is considered
part of the command code.
Power Supply: Power for the input buffers and core logic.
Ground: Ground for the input buffers and core logic.
4
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
VDDQ
Supply DQ Power: Provide isolated power to DQs for improved noise immunity.
VSSQ
Supply DQ Ground: Provide isolated ground to DQs for improved noise immunity.
VREF
Supply Reference Voltage for Inputs: +0.5 x VDDQ
NC
No Connect: No internal connection, these pins suggest to be left unconnected.
Note: The timing reference point for the differential clocking is the cross point of the CK and CK . For any
applications using the single ended clocking, apply VREF to CK pin.
Etron Confidential
5
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Operation Mode
Table 4 shows the truth table for the operation commands.
Table 4. Truth Table (Note (1), (2))
Command
State
BankActivate
BankPrecharge
Precharge All
Write
Write and AutoPrecharge
Read
Read and Autoprecharge
Mode Register Set
Extended Mode Register Set
No-Operation
Device Deselect
Burst Stop
AutoRefresh
SelfRefresh Entry
Idle(3)
SelfRefresh Exit
Any
Any
Active(3)
Active(3)
Active(3)
Active(3)
Idle
Idle
Any
Any
Active(4)
Idle
Idle
Idle
(Self Refresh)
CKEn-1 CKEn DM BA1 BA0
A8 A11-A9, A7-0 CS
H
H
H
H
H
H
H
H
H
H
H
H
H
H
X
X
X
X
X
X
X
X
X
X
X
X
H
L
X
X
X
V
V
X
X
X
X
X
X
X
X
X
V
V
X
V
V
V
V
L
L
X
X
X
X
X
V
V
X
V
V
V
V
L
H
X
X
X
X
X
Row Address
L
X
H
X
L
Column
H
Address
L
A0~A7
H
X
X
X
X
X
X
X
X
X
X
L
H
X
X
X
X
X
OP code
Power Down Mode Entry
Idle/Active(5)
H
L
X
X
X
X
X
Power Down Mode Exit
Any
(Power Down)
L
H
X
X
X
X
X
L
L
L
L
L
L
L
L
L
L
H
L
L
L
H
L
H
L
H
L
X
X
RAS
CAS
L
L
L
H
H
H
H
L
L
H
X
H
L
L
X
H
X
H
X
H
X
X
H
H
H
L
L
L
L
L
L
H
X
H
L
L
X
H
X
H
X
H
X
X
Data Write Enable
Active
H
X
L X
X
X
X
Data Mask Disable
Active
H
X H X
X
X
X
Note: 1. V = Valid data, X = Don't Care, L = Low level, H = High level
2. CKEn signal is input level when commands are provided.
CKEn-1 signal is input level one clock cycle before the commands are provided.
3. These are states of bank designated by BA0, BA1signals.
4. Read burst stop with BST command for all burst types.
5. Power Down Mode can not enter in the burst operation.
When this command is asserted in the burst cycle, device state is clock suspend mode.
Etron Confidential
6
Rev 1.7
WE
H
L
L
L
L
H
H
L
L
H
X
L
H
H
X
H
X
H
X
H
X
X
Nov. 2009
EtronTech
EM6A9320BIA
Mode Register Set (MRS)
The Mode Register stores the data for controlling various operating modes of a DDR SDRAM. It programs
CAS Latency, Burst Type, and Burst Length to make the DDR SDRAM useful for a variety of applications. The
default value of the Mode Register is not defined; therefore the Mode Register must be written by the user.
Values stored in the register will be retained until the register is reprogrammed. The Mode Register is written by
asserting Low on CS , RAS , CAS , WE , BA1 and BA0 (the device should have all banks idle with no bursts in
progress prior to writing into the mode register, and CKE should be High). The state of address pins A0~A11 and
BA0, BA1 in the same cycle in which CS , RAS , CAS and WE are asserted Low is written into the Mode
Register. A minimum of two clock cycles, tMRD, are required to complete the write operation in the Mode
Register. The Mode Register is divided into various fields depending on functionality. The Burst Length uses
A0~A2, Burst Type uses A3, and CAS Latency (read latency from column address) uses A4~A6. A logic 0
should be programmed to all the undefined addresses to ensure future compatibility. Reserved states should not
be used to avoid unknown device operation or incompatibility with future versions. Refer to the table for specific
codes for various burst lengths, burst types and CAS latencies.
Table 5. Mode Register Bitmap
BA1 BA0 A11
0
A8
0
1
X
0
A10
A9
A8
0
A7
Test Mode
0 Normal mode
0
DLL Reset
1
Test mode
BA0 Mode
0
MRS
1 EMRS
A7
T.M.
A6
0
0
0
0
1
1
1
1
A5
0
0
1
1
0
0
1
1
A6
A5
A4
CAS Latency
A4 CAS Latency
0
Reserved
1
Reserved
0
Reserved
1
3
0
Reserved
1
Reserved
0
Reserved
1
Reserved
A3
BT
A2
A1
A0
Burst Length
A3 Burst Type
0 Sequential
1 Interleave
A2
0
0
0
0
1
1
1
1
A1
0
0
1
1
0
0
1
1
A0
0
1
0
1
0
1
0
1
Address Field
Mode Register
Burst Length
Reserved
2
4
8
Reserved
Reserved
Reserved
Reserved
• Burst Length Field (A2~A0)
This field specifies the data length of column access using the A2~A0 pins and selects the Burst Length to be
2, 4, and 8.
Table 6. Burst Length
A2
A1
A0
Burst Length
0
0
0
Reserved
0
0
1
2
0
1
0
4
0
1
1
8
1
0
0
Reserved
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
Etron Confidential
7
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
• Addressing Mode Select Field (A3)
The Addressing Mode can be one of two modes, either Interleave Mode or Sequential Mode. Both Sequential
Mode and Interleave Mode support burst length of 2, 4, and 8.
Table 7. Addressing Mode
•
A3
Addressing Mode
0
Sequential
1
Interleave
Burst Definition, Addressing Sequence of Sequential and Interleave Mode
Table 8. Burst Address ordering
Burst
Length
2
4
8
Start Address
A2
A1
A0
X
X
0
X
X
1
X
0
0
X
0
1
X
1
0
X
1
1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Sequential
Interleave
0, 1
1, 0
0, 1, 2, 3
1, 2, 3, 0
2, 3, 0, 1
3, 0, 1, 2
0, 1, 2, 3, 4, 5, 6, 7
1, 2, 3, 4, 5, 6, 7, 0
2, 3, 4, 5, 6, 7, 0, 1
3, 4, 5, 6, 7, 0, 1, 2
4, 5, 6, 7, 0, 1, 2, 3
5, 6, 7, 0, 1, 2, 3, 4
6, 7, 0, 1, 2, 3, 4, 5
7, 0, 1, 2, 3, 4, 5, 6
0, 1
1, 0
0, 1, 2, 3
1, 0, 3, 2
2, 3, 0, 1
3, 2, 1, 0
0, 1, 2, 3, 4, 5, 6, 7
1, 0, 3, 2, 5, 4, 7, 6
2, 3, 0, 1, 6, 7, 4, 5
3, 2, 1, 0, 7, 6, 5, 4
4, 5, 6, 7, 0, 1, 2, 3
5, 4, 7, 6, 1, 0, 3, 2
6, 7, 4, 5, 2, 3, 0, 1
7, 6, 5, 4, 3, 2, 1, 0
• CAS Latency Field (A6~A4)
This field specifies the number of clock cycles from the assertion of the Read command to the first read data.
The minimum whole value of CAS Latency depends on the frequency of CK. The minimum whole value
satisfying the following formula must be programmed into this field.
tCAC (min) ≤ CAS Latency X tCK
Table 9. CAS Latency
A6
A5
A4
CAS Latency
0
0
0
Reserved
0
0
1
Reserved
0
1
0
Reserved
0
1
1
3 clocks
1
0
0
Reserved
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
Etron Confidential
8
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
• Test Mode Field (A8~A7)
These two bits are used to enter the test mode and must be programmed to "00" in normal operation.
Table 10. Test Mode
•
A8
A7
Test Mode
0
0
Normal mode
1
0
DLL Reset
X
1
Test mode
(BA0, BA1)
Table 11. MRS/EMRS
BA1
BA0
A11 ~ A0
RFU
0
MRS Cycle
RFU
1
Extended Functions (EMRS)
Etron Confidential
9
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Extended Mode Register Set (EMRS)
The Extended Mode Register Set stores the data for enabling or disabling DLL and selecting output driver
strength. The default value of the extended mode register is not defined, therefore must be written after power up
for proper operation. The extended mode register is written by asserting low on CS , RAS , CAS , and WE . (the
device should have all banks idle with no bursts in progress prior to writing into the mode register, and CKE
should be High)The state of A0, A2 ~ A5, A7 ~ A11and BA1 is written in the mode register in the same cycle
as CK , RAS , CAS , and WE going low. The DDR SDRAM should be in all bank precharge with CKE already high
prior to writing into the extended mode register. A1 and A6 are used for setting driver strength to normal, weak or
matched impedance. Two clock cycles are required to complete the write operation in the extended mode
register. The mode register contents can be changed using the same command and clock cycle requirements
during operation as long as all banks are in the idle state. A0 is used for DLL enable or disable. "High" on BA0 is
used for EMRS. Refer to the table for specific codes.
Table 12. Extended Mode Register Bitmap
BA1 BA0 A11 A10
0
1
BA0 Mode
0
MRS
1
EMRS
A9
A8
A7
RFU must be set to “0”
A6
A5
A4
A3
A2
A1
A0
DS1 RFU must be set to “0” DS0 DLL Extended Mode Register
A6 A1
Drive Strength
Comment
0
0
Full
0
1
Weak
1
0
RFU
Reserved For Future
1
1 Matched impedance Output driver matches impedance
Etron Confidential
Address Field
10
A0
0
1
Rev 1.7
DLL
Enable
Disable
Nov. 2009
EtronTech
EM6A9320BIA
Table 13. Absolute Maximum Rating
Symbol
Rating
-4/5
- 0.3 ~ VDDQ+0.3
-0.3 ~ 3.6
0~70
Item
VIN, VOUT Input, Output Voltage
VDD, VDDQ Power Supply Voltage
TA
Ambient Temperature
TSTG
Storage Temperature
Unit
Note
V
V
°C
1,2
1,2
1
°C
°C
1
- 55~150
TSOLDER Soldering Temperature (10s)
260
1
PD
Power Dissipation
2.0
W
1
IOUT
Short Circuit Output Current
50
mA
1
Note1: Stress greater than those listed under “Absolute Maximum Ratings” may cause permanent damage of the
devices
Note2: These voltages are relative to Vss
Table 14. Recommended D.C. Operating Conditions (SSTL_2 In/Out, TA = 0 ~ 70 °C)
Symbol
Parameter
VDD
Power Supply Voltage
VDDQ
VREF
VTT
VIH(DC)
VIL(DC)
VOH
VOL
Power Supply Voltage(for I/O )
Input Reference Voltage
Termination Voltage
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
Min.
2.375
Typ.
2.5
Max.
2.625
Unit
V
Note
1
2.375
2.5
2.625
V
1
0.49 x VDDQ
VREF – 0.04
VREF + 0.15
VSSQ - 0.3
Vtt + 0.76
VREF
-
0.51 x VDDQ
VREF + 0.04
VDDQ + 0.3
VREF- 0.15
-
V
V
V
V
V
IOH = -15.2 mA
-
-
VTT- 0.76
V
IOL = +15.2 mA
IIL
Input Leakage Current
-5
-
5
µA
IOL
Output Leakage Current
-5
-
5
µA
.
Table 15. Capacitance (VDD = 2.5V± 5%, f = 1MHz, TA = 25 °C)
Symbol
CIN1
Parameter
Input Capacitance (CK, CK )
Min.
Max.
Unit
3
5
pF
CIN2
Input Capacitance (All other input-only pins)
4
5
pF
CI/O
DM, DQ, DQS Input/Output Capacitance
6
8
pF
Note: These parameters are guaranteed by design, periodically sampled and are not 100% tested.
Table 16. Decoupling Capacitance Guide Line
Symbol
Parameter
CDC1 Decouping Capacitance between VDD and VSS
CDC2 Decouping Capacitance between VDDQ and VSSQ
Etron Confidential
11
Value
0.1+0.01
0.1+0.01
Unit
µF
µF
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Table 17. D.C. Characteristics (VDD=2.5V ± 5%, TA =0~70°C)
Parameter & Test Condition
Symbol
OPERATING CURRENT: One bank; Active-Precharge; tRC=tRC (min);
tCK=tCK (min); DQ, DM and DQS inputs changing once per clock cycle;
Address and control inputs changing once every two clock cycles.
OPERATING CURRENT : One bank; Active-Read-Precharge; BL=4;
tRC=tRC(min); tCK=tCK(min); lout=0mA; Address and control inputs
changing once per clock cycle
PRECHARGE POWER-DOWN STANDBY CURRENT: All banks idle;
power-down mode; tCK=tCK(min); CKE=LOW
IDLE STANDBY CURRENT : CKE = HIGH; CS =HIGH(DESELECT); All
banks idle; tCK=tCK(min); Address and control inputs changing once per
clock cycle; VIN=VREF for DQ, DQS and DM
ACTIVE POWER-DOWN STANDBY CURRENT : one bank active; powerdown mode; CKE=LOW; tCK=tCK(min)
-5
Max.
Unit
IDD0
220
210
mA
IDD1
260
240
mA
IDD2P
75
75
mA
IDD2N
100
100
mA
IDD3P
75
75
mA
230
220
mA
440
420
mA
440
420
mA
330
300
mA
6
6
mA
600
570
mA
ACTIVE STANDBY CURRENT : CS =HIGH;CKE=HIGH; one bank active ;
IDD3N
tRC=tRC(max);tCK=tCK(min);Address and control inputs changing once per
clock cycle; DQ,DQS,and DM inputs changing twice per clock cycle
OPERATING CURRENT BURST READ : BL=2; READs; Continuous
burst; one bank active; Address and control inputs changing once per clock IDD4R
cycle; tCK=tCK(min); lout=0mA;50% of data changing on every transfer
OPERATING CURRENT BURST Write : BL=2; WRITES; Continuous
Burst ;one bank active; address and control inputs changing once per clock
IDD4W
cycle; tCK=tCK(min); DQ,DQS,and DM changing twice per clock cycle; 50%
of data changing on every transfer
IDD5
AUTO REFRESH CURRENT : tRC=tRFC(min); tCK=tCK(min)
SELF REFRESH CURRENT: Self Refresh Mode ;
IDD6
CKE≦0.2V;tCK=tCK(min)
BURST OPERATING CURRENT 4 bank operation:
Four bank interleaving READs; BL=4;with Auto Precharge; tRC=tRC(min);
tCK=tCK(min); Address and control inputs change only during Active,
READ , or WRITE command
-4
IDD7
Note:
1. Stress greater than those listed under "Absolute Maximum Ratings" may cause permanent
damage of the device.
2. All voltages are referenced to VSS.
3. These parameters depend on the cycle rate and these values are measured by the cycle rate
under the minimum value of tCK and tRC. Input signals are changed one time during tCK.
4. Power-up sequence is described in later page.
Etron Confidential
12
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Table 18. Electrical Characteristics and Recommended A.C. Operating Conditions
(VDD = 2.5V ± 5%, TA = 0~70 °C)
Symbol
-4
Parameter
Min.
4
0.45
0.45
Max.
10
0.55
0.55
Min.
5
0.45
0.45
Max.
10
0.55
0.55
Unit
tCK
tCH
tCL
Clock cycle time
Clock high level width
Clock low level width
tDQSCK
DQS-out access time from CK, CK
-0.7
0.7
-0.7
0.7
ns
tAC
-0.7
0.7
-0.7
0.7
ns
tDQSQ
tRPRE
tRPST
tDQSS
tWPRES
tWPRE
tWPST
tDQSH
tDQSL
tIS
tIH
tDS
tDH
Output access time from CK, CK
DQS-DQ Skew
Read preamble
Read postamble
CK to valid DQS-in
DQS-in setup time
DQS Write preamble
DQS write postamble
DQS in high level pulse width
DQS in low level pulse width
Address and Control input setup time
Address and Control input hold time
DQ & DM setup time to DQS
DQ & DM hold time to DQS
0.4
1.1
0.6
1.15
0.6
-
ns
tCK
tCK
tCK
ns
tCK
tCK
tCK
tCK
ns
ns
ns
ns
Clock half period
-
ns
tQH
tRC
tRFC
tRAS
tRCD
tRP
tRRD
tWR
tMRD
tDAL
tXSRD
tPDEX
tREFI
tIPW
tDIPW
DQ/DQS output hold time from DQS
Row cycle time
Refresh row cycle time
Row active time
Active to Read or Write delay
Row precharge time
Row active to Row active delay
Write recovery time
Mode register set cycle time
Auto precharge write recovery + Precharge time
Self refresh exit to read command delay
Power down exit time
Refresh interval time
Cntrol and Address input pulse width
DQ & DM input pulse width (for each input)
100K
7.8
-
0.9
0.4
0.8
0
0.25
0.4
0.4
0.4
1.0
1.0
0.45
0.45
tCLMIN or
tCHMIN
tHP - tQHS
60
70
40
20
18
2
3
2
tWR + tRP
200
tCK + tIS
2.2
1.75
0.4
1.1
0.6
1.2
0.6
-
tHP
0.9
0.4
0.85
0
0.35
0.4
0.4
0.4
0.9
0.9
0.45
0.45
tCLMIN or
tCHMIN
tHP - tQHS
60
68
40
20
16
3
3
2
tWR + tRP
200
tCK + tIS
2.2
1.75
100K
7.8
-
ns
ns
ns
ns
ns
ns
tCK
tCK
tCK
tCK
tCK
ns
µs
ns
ns
tHZ
Data-out high-impedance window from CK/ CK
-
0.7
-
0.7
ns
tLZ
Data-out low-impedance window from CK/ CK
-0.7
0.7
-0.7
0.7
ns
tQHS
Data Hold Skew Factor
Output data valid window
Exit Self-Refresh to non-Read command
CAS# to CAS# Delay time
tQH - tDQSQ
75
1
0.45
-
tQH - tDQSQ
75
1
0.5
-
ns
ns
ns
tCK
DVW
tXSNR
tCCD
Etron Confidential
CL = 3
-5
13
-
Rev 1.7
ns
tCK
tCK
Nov. 2009
EtronTech
EM6A9320BIA
Table 19. Recommended A.C. Operating Conditions (TA = 0~70 °C, VDD=2.5 ± 5%)
Parameter
Symbol
-4
-5
Min.
Max.
Min.
Max.
Unit
Input High Voltage (AC)
VIH (AC)
VREF + 0.4
-
VREF + 0.4
-
V
Input Low Voltage (AC)
VIL (AC)
-
VREF – 0.4
-
VREF – 0.4
V
Input Different Voltage, CK and CK
inputs
VID (AC)
0.8
VDDQ + 0.6
0.7
VDDQ + 0.6
V
Input Crossing Point Voltage, CK and
CK inputs
VIX (AC) 0.5*VDDQ-0.2 0.5*VDDQ+0.2 0.5*VDDQ-0.2 0.5*VDDQ+0.2 V
Note:
1. All voltages are referenced to VSS.
2. These parameters depend on the cycle rate and these values are measured by the cycle rate under the
minimum value of tCK and tRC. Input signals are changed one time during tCK.
3. Power-up sequence is described in Note 5.
4. A.C. Test Conditions
Table 20. SSTL_2 Interface
Reference Level of Output Signals (VREF)
0.5 * VDDQ
Output Load
Reference to the Test Load
Input Signal Levels
VREF+0.4 V / VREF-0.4 V
Input Signals Slew Rate
1 V/ns
Reference Level of Input Signals
0.5 * VDDQ
Figure 3. SSTL_2 A.C. Test Load
0.5 * VDDQ
50Ω
DQ, DQS
Z0=50Ω
Etron Confidential
14
30pF
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
5. Power up Sequence
Power up must be performed in the following sequence.
1) Apply power to VDD before or at the same time as VDDQ, VTT and VREF when all input signals are held
"NOP" state and maintain CKE “LOW”.
2) Start clock and maintain stable condition for minimum 200us.
3) Issue a “NOP” command and keep CKE “HIGH”
4) Issue a “Precharge All” command.
5) Issue EMRS – enable DLL.
6) Issue MRS – reset DLL. (An additional 200 clock cycles are required to lock the DLL).
7) Precharge all banks of the device.
8) Issue two or more Auto Refresh commands.
9) Issue MRS – with A8 to low to initialize the mode register.
Etron Confidential
15
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Timing Waveforms
Figure 4. Activating a Specific Row in a Specific Bank
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
Address
RA
BA0,1
BA
RA=Row Address
BA=Bank Address
Don’t Care
Etron Confidential
16
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 5. tRCD and tRRD Definition
CK
CK
COMMAND
ACT
Address
Row
Row
Col
BA0,BA1
Bank A
Bank B
Bank B
NOP
NOP
ACT
tRRD
NOP
NOP
RD/WR
NOP
tRCD
Don’t Care
Figure 6. READ Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
CA
A0 - A7
EN AP
A8
DIS AP
BA0,1
BA
CA=Column Address
BA=Bank Address
EN AP=Enable Autoprecharge
DIS AP=Disable Autoprecharge
Don’t Care
Etron Confidential
17
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 7. Read Burst Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
NOP
NOP
CL=3
DQS
DO
n
DQ
DO n=Data Out from column n
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order
following DO n
Don’t Care
Etron Confidential
18
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 8. Consecutive Read Bursts Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
NOP
Bank,
Col n
ADDRESS
READ
NOP
NOP
NOP
Bank,
Col o
CL=3
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4 or 8 (if 4, the bursts are concatenated; if 8, the second burst interrupts the first)
3 subsequent elements of Data Out appear in the programmed order following DO n
3 (or 7) subsequent elements of Data Out appear in the programmed order following DO o
Read commands shown must be to the same device
Don’t Care
Etron Confidential
19
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 9. Non-Consecutive Read Bursts Required CAS Latencies (CL=3)
CK
CK
COMMAND
ADDRESS
READ
NOP
NOP
READ
NOP
NOP
NOP
Bank,
Col o
Bank,
Col n
CL=3
DQS
DO
n
DQ
DO
o
DO n (or o)=Data Out from column n (or column o)
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order following DO n
(and following DO o)
Don’t Care
Etron Confidential
20
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 10. Random Read Accesses Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
READ
READ
READ
Bank,
Col n
Bank,
Col o
Bank,
Col p
Bank,
Col q
ADDRESS
NOP
NOP
CL=3
DQS
DO
n
DQ
DO
n'
DO
o
DO
o'
DO
p
DO n, etc. =Data Out from column n, etc.
n', etc. =the next Data Out following DO n, etc. according to the programmed burst order
Burst Length=2,4 or 8 in cases shown. If burst of 4 or 8, the burst is interrupted
Reads are to active rows in any banks
Don’t Care
Etron Confidential
21
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 11. Terminating a Read Burst Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
ADDRESS
Bank A,
Col n
NOP
BST
NOP
NOP
NOP
CL=3
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are bursts of 8 terminated after 4 data elements
3 subsequent elements of Data Out appear in the programmed order following DO n
Don’t Care
Etron Confidential
22
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 12. Read to Write Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
BST
NOP
NOP
Bank,
Col o
Bank,
Col n
ADDRESS
NOP
WRITE
tDQSS
min
CL=3
DQS
DO
n
DQ
DI
o
DM
DO n (or o)= Data Out from column n (or column o)
Burst Length= 4 in the cases shown (applies for bursts of 8 as well; if burst length is 2, the BST
command shown can be NOP)
1 subsequent element of Data Out appears in the programmed order following DO n
Data in elements are applied following DI o in the programmed order
Don’t Care
Etron Confidential
23
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 13. Read to Precharge Required CAS Latencies (CL=3)
CK
CK
COMMAND
READ
NOP
PRE
NOP
NOP
ACT
tRP
Bank A,
Col n
ADDRESS
Bank
(a or all)
Bank A,
Row
CL=3
DQS
DO
n
DQ
DO n = Data Out from column n
Cases shown are either uninterrupted bursts of 4, or interrupted bursts of 8
3 subsequent elements of Data Out appear in the programmed order
following DO n
Precharge may be applied at (BL/2) tCK after the READ command
Note that Precharge may not be issued before tRAS ns after the ACTIVE
command for applicable banks
The Active command may be applied if tRC has been met
Don’t Care
Etron Confidential
24
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 14. Write Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
CA
A0 - A7
EN AP
A8
DIS AP
BA0,1
BA
CA=Column Address
BA=Bank Address
EN AP=Enable Autoprecharge
DIS AP=Disable Autoprecharge
Don’t Care
Etron Confidential
25
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 15. Write Max DQSS
T0
T1
T2
T3
T4
T5
T6
T7
CK
CK
COMMAND
WRITE
ADDRESS
Bank A,
Col n
NOP
NOP
NOP
tDQSS
max
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data In are applied in the programmed
order following DI n
A non-interrupted burst of 4 is shown
A8 is LOW with the WRITE command (AUTO PRECHARGE disabled)
Don’t Care
Etron Confidential
26
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 16. Write Min DQSS
T0
T1
T2
T3
T4
T5
T6
CK
CK
COMMAND
NOP
WRITE
NOP
NOP
Bank A,
Col n
tDQSS
min
ADDRESS
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data In are applied in the programmed
order following DI n
A non-interrupted burst of 4 is shown
A8 is LOW with the WRITE command (AUTO PRECHARGE disabled)
Don’t Care
Etron Confidential
27
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 17. Write Burst Nom, Min, and Max tDQSS
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
CK
COMMAND
NOP
WRITE
NOP
NOP
NOP
NOP
Bank ,
Col n
ADDRESS
tDQSS (nom)
DQS
DI
n
DQ
DM
tDQSS (min)
DQS
DI
n
DQ
DM
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
3 subsequent elements of Data are applied in the programmed order following DI n
A non-interrupted burst of 4 is shown
A8 is LOW with the WRITE command (AUTO PRECHARGE disabled)
DM=DM0 ~ DM3
Don’t Care
Etron Confidential
28
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 18. Write to Write Max tDQSS
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
Bank ,
Col o
Bank ,
Col n
ADDRESS
WRITE
tDQSS (max)
DQS
DI
n
DQ
DI
o
DM
DI n , etc. = Data In for column n,etc.
3 subsequent elements of Data In are applied in the programmed order following DI n
3 subsequent elements of Data In are applied in the programmed order following DI o
Non-interrupted bursts of 4 are shown
DM= DM 0 ~ DM3
Don’t Care
Etron Confidential
29
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 19. Write to Write Max tDQSS, Non Consecutive
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
CK
COMMAND
WRITE
NOP
NOP
Bank
Col n
ADDRESS
WRITE
NOP
NOP
Bank
Col n
tDQSS (max)
DQS
DI
b
DQ
DI
n
DM
DI n, etc. = Data In for column n, etc.
3 subsequent elements of Data In are applied in the programmed order following DI n
3 subsequent elements of Data In are applied in the programmed order following DI o
Non-interrupted bursts of 4 are shown
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
30
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 20. Random Write Cycles Max tDQSS
T0
T1
T2
T4
T3
T5
T6
T8
T7
T9
CK
CK
COMMAND
ADDRESS
WRITE
WRITE
WRITE
WRITE
WRITE
Bank
Col n
Bank
Col o
Bank
Col p
Bank
Col q
Bank
Col r
tDQSS (max)
DQS
DI
n
DQ
DI
n
DI
o
DI
o
DI
p
DI
p
DI
q
DI
q
DM
DI n, etc. = Data In for column n, etc.
n', etc. = the next Data In following DI n, etc. according to the programmed burst order
Programmed Burst Length 2, 4, or 8 in cases shown
If burst of 4 or 8, the burst would be truncated
Each WRITE command may be to any bank and may be to the same or different devices
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
31
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 21. Write to Read Max tDQSS Non Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
READ
NOP
tWTR
ADDRESS
Bank
Col o
Bank
Col n
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n, etc. = Data In for column n, etc.
1 subsequent elements of Data In are applied in the programmed order following DI n
A non-interrupted burst of 2 is shown
tWTR is referenced from the first positive CK edge after the last Data In Pair
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
32
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 22. Write to Read Max tDQSS Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
READ
NOP
tWTR
ADDRESS
Bank
Col o
Bank
Col n
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n, etc. = Data In for column n, etc.
1 subsequent elements of Data In are applied in the programmed order following DI n
An interrupted burst of 8 is shown, 2 data elements are written
tWTR is referenced from the first positive CK edge after the last Data In Pair
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
33
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 23. Write to Read Max tDQSS, ODD Number of Data, Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
READ
NOP
tWTR
Bank
Col o
Bank
Col n
ADDRESS
CL=3
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
An interrupted burst of 8 is shown, 1 data elements are written
tWTR is referenced from the first positive CK edge after the last Data In Pair (not the last desired
Data In element)
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
The READ and WRITE commands are to the same devices but not necessarily to the same bank
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
34
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 24. Write to Precharge Max tDQSS, NON- Interrupting
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
PRE
tWR
Bank a,
Col n
ADDRESS
Bank
(a or al)
tRP
tDQSS (max)
DQS
DI
n
DQ
DM
DI n = Data In for column n
1 subsequent elements of Data In are applied in the programmed order following DI n
A non-interrupted burst of 2 is shown
tWR is referenced from the first positive CK edge after the last Data In Pair
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
35
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 25. Write to Precharge Max tDQSS, Interrupting
T0
T1
T2
T3
T4
T5
T6
T8
T7
T9
T10
T11
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
PRE
NOP
tWR
Bank a,
Col n
ADDRESS
Bank
(a or all)
tDQSS (max)
tRP
*2
DQS
DI
n
DQ
DM
*1
*1
*1
*1
DI n = Data In for column n
An interrupted burst of 4 or 8 is shown, 2 data elements are written
tWR is referenced from the first positive CK edge after the last Data In Pair
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
*1 = can be don't care for programmed burst length of 4
*2 = for programmed burst length of 4, DQS becomes don't care at this point
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
36
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 26. Write to Precharge Max tDQSS ODD Number of Data Interrupting
T0
T1
T2
T3
T4
T5
T6
T8
T7
T9
T10
T11
CK
CK
COMMAND
WRITE
NOP
NOP
NOP
NOP
PRE
tWR
Bank a,
Col n
ADDRESS
Bank
(a or all)
tDQSS (max)
tRP
*2
DQS
DI
n
DQ
DM
*1
*1
*1
*1
DI n = Data In for column n
An interrupted burst of 4 or 8 is shown, 1 data element is written
tWR is referenced from the first positive CK edge after the last Data In Pair
A8 is LOW with the WRITE command (AUTO PRECHARGE is disabled)
*1 = can be don't care for programmed burst length of 4
*2 = for programmed burst length of 4, DQS becomes don't care at this point
DM= DM0 ~ DM3
Don’t Care
Etron Confidential
37
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 27. Precharge Command
CK
CK
CKE
HIGH
CS
RAS
CAS
WE
A0-A7,
A9-A11
ALL BANKS
A8
ONE BANK
BA0,1
BA
BA= Bank Address (if A8 is LOW,
otherwise don't care)
Don’t Care
Etron Confidential
38
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 28. Power-Down
T0
T1
T2
T3
T4
Tn
Tn+3 Tn+4 Tn+5 Tn+6
Tn+1 Tn+2
CK
CK
tIS
tIS
CKE
COMMAND
NOP
NOP
VALID
No column access
in progress
VALID
Exit power-down
mode
Enter power-down
mode
Don’t Care
Figure 29. Clock Frequency Change in Precharge
T0
T1
T2
T4
Tx
Tx+1
Ty
Ty+1
Ty+2
Ty+3
Ty+4
Tz
CK
CK
NOP
CMD
NOP
NOP
NOP
NOP
Valid
tIS
Frequency Change
Occurs here
CKE
DLL
RESET
tRP
Minmum 2 clocks
Required before
Changing frequency
Etron Confidential
Stable new clock
Before power down exit
39
200 Clocks
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 30. Data input (Write) Timing
tDQSH
tDQSL
DQS
tDS
DI
n
DQ
tDH
tDS
DM
tDH
DI n = Data In for column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are applied in the programmed order
following DI n
Don’t Care
Figure 31. Data Output (Read) Timing
tCH
tCL
CK
CK
DQS
DQ
tDQSQ
tDQSQ
max
max
tQH
tQH
Burst Length = 4 in the case shown
Etron Confidential
40
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 32. Initialize and Mode Register Sets
VDD
VDDQ
tVDT>=0
VTT
(system*)
VREF
tCK
tCH tCL
CK
CK
tIS tIH
CKE
tIS tIH
NOP
COMMAND
PRE
MRS
EMRS
AR
AR
PRE
MRS
ACT
CODE
RA
CODE
RA
BA0=L
BA1=L
BA
DM
tIS tIH
A0-A7,
A9-A11
CODE
ALL BANKS
A8
CODE
tIS tIH
ALL BANKS
CODE
tIS tIH
CODE
tIS tIH
tIS tIH
BA0=H
BA1=L
BA0,BA1
BA0=L
BA1=L
High-Z
DQS
High-Z
DQ
T=200µs
Power-up:
VDD and
CLK stable
**tMRD
Extended mode
Register set
**tMRD
tRP
tRFC
tRFC
**tMRD
200 cycles of CK**
Load Mode
Register,
(with A8=L)
Load Mode
Register,
Reset DLL (with A8=H)
*=VTT is not applied directly to the device, however tVTD must be greater than or equal to zero to avoid device latch-up
**=tMRD is required before any command can be applied, and 200 cycles of CK are required before any executable command can be applied
The two Auto Refresh commands may be moved to follow the first MRS but precede the second PRECHARGE ALL command
Don’t Care
Etron Confidential
41
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 33. Power Down Mode
tCK
tCH
tCL
CK
CK
tIS tIH
tIS
tIS
CKE
tIS tIH
COMMAND
VALID*
NOP
NOP
VALID
tIS tIH
ADDR
VALID
VALID
DQS
DQ
DM
Enter power-down
mode
Exit power-down
mode
No column accesses are allowed to be in progress at the time Power-Down is entered
*=If this command is a PRECHARGE ALL (or if the device is already in the idlestate) then the Power-Down
mode shown is Precharge Power Down. If this command is an ACTIVE (or if at least one row is already active)
then the Power-Down mode shown is active Power Down.
Don’t Care
Etron Confidential
42
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 34. Auto Refresh Mode
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
VALID
tIS tIH
NOP
COMMAND
PRE
NOP
NOP
AR
NOP
AR
NOP
NOP
ACT
A0-A7
RA
A9-A11
RA
ALL BANKS
A8
RA
ONE BANKS
tIS
BA0,BA1
tIH
RA
*Bank(s)
DQS
DQ
DM
tRP
*=
tRFC
tRFC
Don't Care , if A8 is HIGH at this point; A8 must be HIGH if more than one bank is active (i.e., must precharge all active banks)
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other valid commands may be possible after tRFC
DM, DQ and DQS signals are all
Don't Care /High-Z for operations shown
Don’t Care
Etron Confidential
43
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 35. Self Refresh Mode
tCK
tCH
Clock must be stable before
Exiting Self Refresh mode
tCL
CK
CK
tIS tIH
tIS
tIS
CKE
tIS tIH
COMMAND
NOP
NOP
AR
VALID
tIS tIH
VALID
ADDR
DQS
DQ
DM
tRP*
tXSNR/
tXSRD**
Enter Self Refresh
mode
Exit Self Refresh
mode
* = Device must be in the All banks idle state prior to entering Self Refresh mode
** = tXSNR is required before any non-READ command can be applied, and tXSRD (200 cycles of CK) is
required before a READ command can be applied.
Don’t Care
Etron Confidential
44
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 36. Read without Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
NOP
COMMAND
READ
PRE
NOP
NOP
NOP
ACT
tIS tIH
Col n
A0-A7
RA
RA
A9-A11
tIS
tIH
ALL BANKS
RA
A8
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Bank X
*Bank X
CL=3
tRP
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPRE
tRPST
DQS
tLZ
min
DO
n
DQ
tLZ
tAC
min
Case 2:
tAC/tDQSCK=max
min
tDQSCK
max
tRPRE
tRPST
DQS
tLZ
max
tHZ
max
DO
n
DQ
tLZ
max
tAC
max
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A8 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other commands may be valid at these times
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Etron Confidential
45
Don’t Care
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 37. Read with Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
NOP
COMMAND
READ
NOP
NOP
NOP
NOP
ACT
tIS tIH
Col n
A0-A7
RA
RA
A9-A11
EN AP
RA
A8
tIS tIH
tIS tIH
Bank X
BA0,BA1
Bank X
CL=3
tRP
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPST
tRPRE
DQS
tLZ
min
DO
n
DQ
tLZ
tAC
min
min
Case 2:
tAC/tDQSCK=max
tDQSCK
max
tRPST
tRPRE
DQS
tLZ
max
tHZ
max
DO
n
DQ
tLZ
max
tAC
max
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
EN AP = Enable Autoprecharge
ACT = ACTIVE, RA = Row Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
The READ command may not be issued until tRAP has been satisfied. If Fast Autoprecharge is supported, tRAP = tRCD, else the READ
may not be issued prior to tRASmin (BL*tCK/2)
Don’t Care
Etron Confidential
46
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 38. Bank Read Access
tCK
tCH tCL
CK
CK
tIS tIH
CKE
tIS tIH
NOP
COMMAND
ACT
NOP
NOP
NOP
READ
NOP
PRE
NOP
NOP
ACT
tIS tIH
A0-A7
RA
A9-A11
RA
Col n
RA
tIS
A8
RA
tIH
ALL BANKS
RA
RA
DIS AP
ONE BANKS
Bank X
*Bank X
tIS tIH
Bank X
BA0,BA1
Bank X
tRC
tRAS
tRCD
tRP
CL=3
DM
Case 1:
tAC/tDQSCK=min
tDQSCK
min
tRPRE
tRPST
DQS
tLZ
DO
n
min
DQ
tLZ
tAC
tDQSCK
min
Case 2:
tAC/tDQSCK=max
min
max
tRPRE
DQS
tHZ
tLZ
max
max
DO
n
DQ
tLZ
DO n = Data Out from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DO n
tRPST
max
tAC
max
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A8 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Note that tRCD > tRCD MIN so that the same timing applies if Autoprecharge is enabled (in which case tRAS
would be limiting)
Etron Confidential
47
Don’t Care
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 39. Write without Auto Precharge
tCK
tCH tCL
CK
CK
tIH
tIS tIH
CKE
VALID
tIS tIH
NOP
COMMAND
NOP
NOP
NOP
WRITE
NOP
PRE
NOP
NOP
ACT
tIS tIH
RA
Col n
A0-A7
RA
A9-A11
tIS tIH
ALL BANKS
RA
A8
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Case 1:
tDQSS=min
tDQSS
BA
*Bank X
tDSH
tDQSH
tRP
tDSH
tWR
tWPST
DQS
tDQSL
tWPRES
tWPRE
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDQSS
tDQSH
tDSS
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A8 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address, AR = AUTOREFRESH
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the +
25% window of the corresponding positive clock edge
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Etron Confidential
48
Rev 1.7
Don’t Care
Nov. 2009
EtronTech
EM6A9320BIA
Figure 40. Write with Auto Precharge
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
VALID
VALID
NOP
NOP
NOP
tIS tIH
COMMAND
NOP
WRITE
NOP
NOP
NOP
NOP
ACT
tIS tIH
RA
Col n
A0-A7
RA
A9-A11
DIS AP
RA
A8
tIS tIH
Bank X
BA0,BA1
BA
tDAL
Case 1:
tDQSS=min
tDQSS
tDSH
tDQSH
tDSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tDSS
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DI n
EN AP = Enable Autoprecharge
ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Don’t Care
Etron Confidential
49
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 41. Bank Write Access
tCK
tCH tCL
CK
CK
tIS tIH
CKE
tIS tIH
NOP
COMMAND
ACT
NOP
NOP
WRITE
NOP
NOP
NOP
NOP
PRE
tIS tIH
A0-A7
RA
A9-A11
RA
A8
RA
Col n
tIS tIH
ALL BANKS
DIS AP
ONE BANK
tIS tIH
Bank X
BA0,BA1
Bank X
*Bank X
tRAS
tRCD
Case 1:
tDQSS=min
tWR
tDQSS
tDSH
tDQSH
tDSH
tWPST
DQS
tWPRES
tWPRE
tDQSL
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDSS
tDQSH
tDQSS
tWPST
DQS
tWPRES
tWPRE
tDQSL
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data Out are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care
, if A8 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Don’t Care
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Etron Confidential
50
Rev 1.7
Nov. 2009
EtronTech
EM6A9320BIA
Figure 42. Write DM Operation
tCK
tCH tCL
CK
CK
tIS tIH
CKE
VALID
tIS tIH
NOP
COMMAND
WRITE
NOP
NOP
NOP
NOP
PRE
NOP
NOP
ACT
tIS tIH
RA
Col n
A0-A7
RA
A9-A11
tIS tIH
ALL BANKS
RA
A8
ONE BANKS
DIS AP
tIS tIH
Bank X
BA0,BA1
Case 1:
tDQSS=min
BA
*Bank X
tDQSS
tDSH
tDQSH
tRP
tDSH
tWR
tWPST
DQS
tDQSL
tWPRES
tWPRE
DI
n
DQ
DM
tDSS
Case 2:
tDQSS=max
tDQSS
tDSS
tDQSH
tWPST
DQS
tWPRES
tDQSL
tWPRE
DI
n
DQ
DM
DI n = Data In from column n
Burst Length = 4 in the case shown
3 subsequent elements of Data In are provided in the programmed order following DI n
DIS AP = Disable Autoprecharge
*=
Don't Care , if A8 is HIGH at this point
PRE = PRECHARGE, ACT = ACTIVE, RA = Row Address, BA = Bank Address
NOP commands are shown for ease of illustration; other commands may be valid at these times
Although tDQSS is drawn only for the first DQS rising edge, each rising edge of DQS must fall within the + 25%
window of the corresponding positive clock edge
Precharge may not be issued before tRAS ns after the ACTIVE command for applicable banks
Etron Confidential
51
Rev 1.7
Don’t Care
Nov. 2009
EtronTech
EM6A9320BIA
Figure 43. 144 ball LFBGA Package Outline Drawing Information
Units: mm
PIN #1
Top View
"A"
Bottom View
Side View
DETAIL : "A"
Symbol
A
A1
A2
D
E
D1
E1
e
b
Etron Confidential
Dimension in inch
Dimension in mm
Min
Nom Max
Min
Nom Max
--0.055
--1.40
0.012 0.014 0.016 0.30 0.35 0.40
0.036 0.038 0.040 0.91 0.96 1.01
0.469 0.472 0.476 11.90 12.00 12.10
0.469 0.472 0.476 11.90 12.00 12.10
-0.346
--8.80
--0.346
--8.80
--0.031
--0.80
-0.016 0.018 0.020 0.40 0.45 0.50