MA-COM PS000SD6D

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
The CHAMELEON Adaptable Module for DC Applications
P Series
EN
60 950
UL Recognized
CSA Certified
TUV Certified
P Series
Specifications
• Full flexibility of design in the most compact
package
• General purpose designed for DC applications
• Mates with a standard MOLEX* connector (HCS
Series) which prevents accidental connection to
AC Power
Ordering Information
P S 0 0 0 D D3D
(DC Version)
Current Rating
3 = 3A
6 = 6A
X = 10A
Filter Type
D = DC version
Fuse Options
D = Dual fuse
S = Single fuse
Input Voltage Select
0 = Single voltage
Switch Options
0 = No switch
Extender Options
0 = None
Rated Voltage (max):
80 VDC
Rated Current:
3 to 10A
Fuseholder*:
Terminals:
2250 VDC
1450 VDC
.25 x 1.25” or
5 x 20 mm
.187 x .032 [4.8 x .81] terminal tabs
4
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
DC Filters
Shield Options
D = Complete Shield
Hipot rating (one minute):
Line to Ground:
LIne to Line:

Electrical Schematic
LINE
LOAD
Available Part Numbers
PE000DD3D
PE000DD6D
PE000DDXD
PE000SD3D
PE000SD6D
PE000SDXD
Mounting Style
E = Mounting ears
S = Snap-in
PS000DD3D
PS000DD6D
PS000DDXD
PS000SD3D
PS000SD6D
PS000SDXD
  
223
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
The CHAMELEON Adaptable Module for DC Applications (continued)
P Series
Case Styles
Case Dimensions
PE
Part No.
B
C
D



E
F
 

     
     
    

    
PE
C
A
PS
 
Recommended Panel Cutouts
F
A
.06
R Max.
1.52
B
.07
1.78
min. Radius
Ground connection
PS
E
External Edge
(1) .020 R Min.
.508
C
D
B
Note: The external edges (installation side) on the "D" sides of the
cutout should have a minimum .020" radius. For optimal retention
against extraction, the corresponding inner edge should be sharp,
without paint or coatings. Edge coatings, including anodization are
also discouraged for good shield contact.
A
Performance Data
Accessories
Minimum Insertion Loss
Red
Black
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)


GA210 – (shown above) Pre-assembled connector
housing with two 36” long 18 gauge wires to mate
with P Series DC filters

 













 
























Differential Mode / Symmetrical (Line to Line)
MOLEX Part Numbers:
03-12-1026
DC Connector housing for P Series




 



18-12-1222
Female terminals (2 per connector)



























224
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com