CYPRESS SPX-2000

SUPREX® II
CYPRESS
Connection Diagram
INDUSTRY LEADERS DEPEND ON US ...FOR SOLUTIONS
Cypress Computer Systems, Inc. • 1778 Imlay City Rd. • Lapeer, MI 48446-3206
TX(810)245-2300 • FX(810)245-2332 • www.cypresscom.com
}A
8
7
6
5
4
3
2
1
SUPREX
Remote Unit
Off
Line +
On
LED
RS-232
Connector
Line +8 to +24 Vdc @ 150 ma
Ground
Dip
Switch
Off
Line +
Line -
SUPREX
Central Unit
On
LED
RS-232
Connector
+8 to +24 Vdc @ 150 ma
Ground
OUTPUT RELAYS
8
7
6
5
4
3
2
1
}C
Aux Relay
Control
+5 Vdc @ 100 ma
Data 0 / Clock
Data 1 / Data
LED
Program
Resistor #2
Program
Resistor #1
Ground
READER
Input 1
+8 to +24 Vdc @ 150 ma
Dip
Switch
D{
C{
ACCESS CONTROL
PANEL
}B
OUTPUT RELAYS
Input 2
B{
A{
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
}
}
Door Strike Relay
125 Vac @ 1 Amp
Aux Output Relay
125 Vac @ 1 Amp
+8 to +24 Vdc @ 150 ma
To control door strike
relay, short LED to
Ground
Ground
+5 Vdc @ 100 ma
Data 0 / Clock
}D
Data 1 / Data
LED
Normally Closed
Common
Normally Open
Normally Closed
Common
Normally Open
}
}
Trouble / Output Relay 2
125 Vac @ 1 Amp
Output Relay 1
125 Vac @ 1 Amp
Actual size of each circuit board is
4-1/2” x 2-5/8”
1 2 3 4
5 6 7 8
9
RS-232 DB-9 Male
2 - Receive
3- Transmit
5 - Ground
SUPREX® II Remote Unit Dip Switch Setting
Switch #2 - On = Door Strike Relay does NOT follow LED status.
Off = Door Strike Relay follows status of LED.
Switch #6* - On = Bit mode (Noise filter off) for keypad applications.
Off = Noise filter mode, standard reader applications
(Default setting)
SUPREX® II Central Unit Dip Switch Setting
Switch #3 - On = Inverts idle on MagStripe version
Off = Normal operation of MagStripe version
Switch #4 - On = Inverts Aux 2 Relay Status
Off = Normal operation
*Not active on versions earlier than 2-1-2003
When wired and powered up corectly, LEDs on
Remote and Centrol will blink 5 to 10 times per
second. When there is a problem with
communication between the Remote and
Central, the LED on the Central will blink 2
times per second and the Remote LED
will not light at all.
Part Numbers:
• SPX-2000 : Wiegand format (RS-485)
• SPX-2100 : MagStripe format (RS-485)
• SPX-2500 : Wiegand format (RS-232)
• SPX-2600 : MagStripe format (RS-232)
Typical 2-Wire Communications Installation
Power Supply
Line+
Line Pwr
Gnd
Remote
10,000 Ft
Power Supply
Pwr
Gnd
Central
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
Typical 4-Wire Communications
Installation with Wiegand Reader
Gnd
+5vDC
Data 0
Data 1
LED
End of Line Device
Wiegand Reader
Line+
LinePwr
Gnd
Remote
Power
Supply
10,000 Ft.
Door Strike
Programming Resistor
12vDC
Gnd
Data 0
Data 1
LED
Supervised Trouble Input
Supervised Alarm Input
Central
Weigand Controller
• The Controller's LED signal changes the state of the Door Strike relay.
• The Controller's Supervised Alarm Input monitors the state of the End-of-Line Device.
• If loss of power or communication occurs, the Supervised Trouble Input will activate.
• The Programming Resistor 1 is used to calibrate the Remote Unit's Alarm Input 1 Sensor.
(Any End-of-Line value from 100 Ω to 20KΩ can be monitored by using the same value for the Programming Resistor.)
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
Typical 4-Wire Communications Installation
with MagStripe Reader
SPX-2100 Series
Gnd
+5vDC
Clock
Data
LED
End of Line Device
MagStripe Reader
Line+
LinePwr
Gnd
Remote
Power
Supply
10,000 Ft.
Door Strike
Programming Resistor
12vDC
Gnd
Clock
Data
LED
Supervised Trouble Input
Supervised Alarm Input
Central
MagStripe Controller
• The Controller's LED signal changes the state of the Door Strike relay.
• The Controller's Supervised Alarm Input monitors the state of the End-of-Line Device.
• If loss of power or communication occurs, the Supervised Trouble Input will activate.
• The Programming Resistor 1 is used to calibrate the Remote Unit's Alarm Input 1 Sensor.
(Any End-of-Line value from 100 Ω to 20KΩ can be monitored by using the same value for the Programming Resistor.)
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
SUPERVISED Status Monitoring
Remote
End of Line Device
Programming Resistor
Central
Supervised Alarm Input
Programming Resistor
Remote
Supervised Alarm Input
Central
End of Line Device
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
UN-SUPERVISED Status Monitoring
SW2
SW1
Remote
Switches
(ie: Request-To-Exit, Door
Sending Unsupervised Status from Remote to C
Central
SW2
SW1
Normally Op
Contacts wil
status of sw
Remote
SW2
SW1
Normally Open
Contacts will follow
status of switch
Sending Unsupervised Status from Central to Rem
Central
SW1
GND
SW2
LED
Switches or Relay Contacts
211128
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com