JDSU FFS

COMMUNICATIONS COMPONENTS
Fused Coupler, Near Infrared
Key Features
• 700 to 1150 nm operation
• Available in any coupling ratio
• All fiber — no lens alignment
• No unwanted reflections
• Low light loss
• High power handling
Applications
• Fiber lasers
• Sensors
• Avionics
• Biomedical equipment
• Research
NORTH AMERICA : 800 498-JDSU (5378)
The JDSU near infrared fused coupler splits or combines light at any selected
wavelength from 700 to 1150 nm. Designed for applications in fiber laser, sensor
and avionics applications, the coupler utilizes low loss fused fiber technology. No
light leaves the fiber and therefore no alignment is required; and there are no
unwanted reflections. Furthermore the output fiber pigtails may be directly
integrated into beam delivery systems.
WORLDWIDE : +800 5378-JDSU
WEBSITE : www.jdsu.com
FUSED COUPLER, NEAR INFRARED
2
Configuration
1x2
P2 (Blue) SIGNAL (Input)
P1 (Red) COMMON (Input)
P3 (Red) TAP (Output)
2x2
P1 (Red) COMMON (Input)
P2 (Blue) SIGNAL (Input)
P4 (Blue)
P3 (Red) TAP (Output)
Insertion Loss
Coupling Ratio
Grade
Available Housing Option
Signal Path Insertion Loss1, 2
(Maximum)
Tap Path Insertion Loss1, 2
(Maximum)
10%
10%
20%
20%
30%
30%
40%
40%
50%
50%
A
B
A
B
A
B
A
B
A
B
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
3, 4, 5, 6
0.9 dB
1.1 dB
1.5 dB
1.7 dB
2.2 dB
2.4 dB
3.0 dB
3.2 dB
3.8 dB
4.0 dB
12.2 dB
12.4 dB
8.4 dB
8.6 dB
6.4 dB
6.5 dB
4.9 dB
5.1 dB
3.8 dB
4.0 dB
1. Insertion loss at operating wavelength range (not including PDL, TDL or connector losses).
2. In 2x2 couplers with a coupling ratio of 20% or lower, insertion loss is not specified for launch through second input port (P4).
FUSED COUPLER, NEAR INFRARED
3
Housing Option
Housing Code
Description
1x2, 2x2 Dimensions (mm)
Pigtail
3
4
5
6
Regular
Ø 0.9 mm slim
Ø 0.9 mm semi-ruggedized
Ø 3.0 mm fully ruggedized
3.0 (Ø) x 50 (L)
3.0 (Ø) x 60 (L)
5.0 (Ø) x 75 (L)
80 (L) x 10 (W) x 8 (H)
Primary-coated fiber
Ø 0.9 mm loose-tube
Ø 0.9 mm loose-tube
Ø 3.0 mm fan-out sleeving
Specifications
Parameter
Operating wavelength range1
Excess loss
Return loss/Directivity
Pigtail tensile load
Optical power handling
Operating temperature range2
Storage temperature range
Fiber type
Grade A
Typical
Minimum
Maximum
Maximum
Grade B
Any wavelength within the 700 to 1150 nm range
0.30 dB
0.50 dB
50 dB
5N
4W
-40 to 75 °C
-40 to 85 °C
Speciality fiber
1. Any specific wavelength point from within the range 633 to 850 nm may be selected. For wavelengths outside of this range, contact JDSU with specific requirements.
2. For connectorised component, operating temperature range is -5 to 75 °C.
FUSED COUPLER, NEAR INFRARED
4
Ordering Information
For more information on this or other products and their availability, please contact your local JDSU account manager or
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at
[email protected].
Sample: FFS-060K31A10 (Fused Fiber Speciality Coupler, 1060 nm, 50/50 coupling ratio, regular housing, 1x2, A grade, 1 m
pigtails, no connectors)
FFSCode
7
8
9
0
1
Wavelength
(First Digit)
7xx nm
8xx nm
9xx nm
10xx nm
11xx nm
Code
Wavelength
(Second and
Third Digit)
Examples:
33
x33 nm
32
x32 nm
57
x57 nm
Code
A
C
E
H
K
Coupling Ratio1
10%
20%
30%
40%
50%
Code
3
4
5
Housing2
Regular
Ø 0.9 mm slim
Ø 0.9 mm
semi-ruggedised
Ø 3.0mm fully
ruggedised
6
Code
1
2
Configuration
1x2
2x2
Code
A
B
Grade
Grade A
Grade B
Code
Pigtail Length3
(Minimum)
0.5 meter
1 meter
0
1
Code
0
1
3
5
9
A
B
Connectors2, 4
None
FC/PC
FC/APC
SC/APC
FC/UPC
SC/UPC
LC5
1. Other coupling ratio are available. Please contact JDSU for ordering codes of coupling ratios not listed.
2. Connectors may be fitted to housing types 4, 5 and 6. For connectorisation of housing type 3, please contact JDSU sales office.
3. Minimum pigtail length. Other pigtail lengths are available on request. When the pigtail has been modified to include a
connector, pigtail length measurment includes the connector end face.
4. Excess Loss in specification table does not include connector losses.
5. LC connector is not available for housing code 6, fully ruggedised housing.
LC is a registered trademark of Lucent Technologies.
NORTH AMERICA : 800 498-JDSU (5378)
WORLDWIDE : +800 5378-JDSU