VISHAY SRP600J

SRP600A thru SRP600K
Vishay General Semiconductor
Fast Switching Plastic Rectifier
FEATURES
• Fast switching for high efficiency
• Low forward voltage drop
• Low leakage current
• High forward current operation
• High forward surge capability
• Solder dip 275 °C max. 10 s, per JESD 22-B106
P600
• Compliant to RoHS directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
TYPICAL APPLICATIONS
For use in fast switching rectification of power supply,
inverters, converters and freewheeling diodes for consumer
and telecommunication.
PRIMARY CHARACTERISTICS
IF(AV)
6.0 A
VRRM
50 V to 800 V
IFSM
300 A
Note
• These devices are not AEC-Q101 qualified.
trr
100 ns, 150 ns, 200 ns
VF
1.3 V
IR
10 μA
TJ max.
125 °C
MECHANICAL DATA
Case: P600, void-free molded epoxy body
Molding compound meets UL 94 V-0 flammability rating
Base P/N-E3 - RoHS compliant, commercial grade
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
E3 suffix meets JESD 201 class 1A whisker test
per
Polarity: Color band denotes cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
SRP600A
SRP600B
SRP600D
SRP600G
SRP600J
SRP600K
UNIT
Maximum repetitive peak reverse voltage
VRRM
50
100
200
400
600
800
V
Maximum RMS voltage
VRMS
35
70
140
280
420
560
V
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
V
Maximum average forward rectified current
0.375" (9.5 mm) lead length at TA = 55 °C
IF(AV)
6.0
A
Peak forward surge current 8.3 ms single
half sine-wave superimposed on rated load
IFSM
300
A
TJ
- 50 to + 125
°C
TSTG
- 50 to + 150
°C
Operating junction temperature range
Storage temperature range
Document Number: 88745
Revision: 27-Oct-09
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
SRP600A thru SRP600K
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum
instantaneous
forward voltage
6.0 A
SYMBOL
VF
Maximum DC reverse
current at rated DC
blocking voltage
SRP600J
SRP600K UNIT
1.3
V
10
μA
1.0
mA
TA = 25 °C
IR
TA = 100 °C
IF = 0.5 A, IR = 1.0 A,
Irr = 0.25 A
Maximum reverse
recovery time
SRP600A SRP600B SRP600D SRP600G
100
trr
150
200
ns
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Typical thermal resistance
RθJA
SRP600A SRP600B SRP600D SRP600G
(1)
SRP600J
SRP600K UNIT
10
°C/W
Note
(1) Thermal resistance from junction to ambient at 0.375" (9.5 mm) lead length with both leads equally heat sink
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
SRP600J-E3/54
2.1
54
800
13" diameter paper tape and reel
SRP600J-E3/73
2.1
73
300
Ammo pack packaging
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
7.0
20
Resistive or Inductive Load
6.0
5.0
1.1" x 1.1" (30 mm x 30 mm)
Copper Pads
4.0
Ipk
=π
IAV
3.0
Capacitive
Loads
5.0
Ipk
= 10
IAV
20
2.0
1.0
0
Average Forward Current (A)
Average Forward Current (A)
Resistive or Inductive Load
L=
16
0.1
2"
L=
12
(3.2
mm
)
0.25
" (6
L=0
8
1.6" x 1.6" x 0.04"
(40 mm x 40 mm x 1 mm)
Copper Heatsinks
.3 m
m)
.375
" (9.
L = Lead Length
5 mm
L = 0.6
2" (15
.9
)
mm)
4
0
20
40
60
80
100
120
140
160
180
75
80
85
90
95
100 105 110 115 120 125
Ambient Temperature (°C)
Lead Temperature (°C)
Fig. 1 - Forward Current Derating Curves
Fig. 2 - Forward Current Derating Curve
www.vishay.com
2
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 88745
Revision: 27-Oct-09
SRP600A thru SRP600K
Vishay General Semiconductor
10
8.3 ms Single Half Sine-Wave
Instantaneous Reverse Current (μA)
Peak Forward Surge Current (A)
400
350
300
TJ = 25 °C
250
200
TJ = 125 °C
150
TJ = 100 °C
1
TJ = 50 °C
0.1
TJ = 25 °C
0.01
100
100
10
1
0
20
40
60
80
100
Number of Cycles at 60 Hz
Percent of Rated Peak Reverse Voltage (%)
Fig. 3 - Maximum Non-Repetitive Peak Forward Surge Current
Fig. 5 - Typical Reverse Characteristics
25
L = Lead Lengths
RθJL Thermal Resistance
from Junction to Lead (°C/W)
Instantaneous Forward Current (A)
100
TJ = 25 °C
Pulse Width = 300 μs
1 % Duty Cycle
10
1
0.1
0.6
20
Copper Heatsinks
15
10
5
0
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
Instantaneous Forward Voltage (V)
Equal Lead Lengths to Heatsink (inches)
Fig. 4 - Typical Instantaneous Forward Characteristics
Fig. 6 - Typical Thermal Resistance
1.0
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
P600
1.0 (25.4)
MIN.
0.360 (9.1)
0.340 (8.6)
0.360 (9.1)
0.340 (8.6)
0.052 (1.32)
0.048 (1.22)
DIA.
Document Number: 88745
Revision: 27-Oct-09
1.0 (25.4)
MIN.
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1