LEM HY50

Current Transducers, HY 50-P/SP1
IPN
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
=
50 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
± 150
50
VC
IC
ÎP
Vd
Vb
R IS
VOUT
Primary
conductor
(mm)
Type
1.6 x 3.5
HY 50-P/SP1
Features
Supply voltage (± 5 %)
single
Current consumption
Overload capability (1 ms)
R.m.s. voltage for AC isolation test, 50/60Hz, 1 min
R.m.s. rated voltage,safe separation
Isolation resistance @ 500 VDC
Output voltage @ + IPN, RL = 10 kΩ, TA = 25°C
Output voltage @ - IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
ROUT
RL
+5
10
50 x IPN
2.5
5001)
> 1000
2.5
1.5
100
>1
V DC
mA
kV
V
MΩ
V
V
Ω
kΩ
Accuracy - Dynamic performance data
X
ε
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0
after an excursion of 1 x IPN
Thermal drift of VOE
L
VOE
VOH
VOT
TCε
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 3) (0 .. - 3 dB)
G
tr
di/dt
f
<±2
%
< ± 1 % of IPN
< + 2V ± 25 mV
typ
max
< ± 10
mV
± 1.5
mV/K
±3
mV/K
< ± 0.1
%/K
<5
µs
> 50
A/µs
DC .. 50
kHz
General data
TA
TS
m
Notes :
Ambient operating temperature
Ambient storage temperature
Mass
Standards 4)
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
g
EN50178
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500 V~
• Compact design for PCB mounting
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• Easy mounting
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
Applications
• General purpose inverters
• Switched-Mode Power Supplies
(SMPS)
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications.
1)
Pollution class 2, overvoltage category III
Linearity data exclude the electrical offset.
3)
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4)
Please consult characterisation report for more techinical details and
application advises.
2)
980723/2
LEM Components
www.lem.com
HY 50-P/S P 1
D im e ns io ns (in m m )
36 .0 M ax .
32 .0 M ax .
JA PA N
18 .0
12 M ax .
12 .0
HY 5 0 - P
/S P 1
9 70 8
1.6
3 .5
3 .0 ±0 .5
5 .5 ±0 .2
7 .0 ±0 .2
2 x 2 .54
2 0 .0 ±0 .3
1 2 3
4
5
1.6 ±0 .3
3 .9 ±0 .3
PC B M O U NT ING D IM E NS IO NS (in m m ±0 .1, ho le -0 , +0 .2 )
HY 50-P/S P 1
3 .5
ho le s d ia 2 .2
3 ho le s d ia 1
PIN A R RA NG EM E NT
1 +5V
2 O UT P UT
3 0V
2 x 2 .54
5 .5
2 0 .0
LEM reserves the right to change limits and dimensions.
4 PR IMA RY IN
5 PR IMA RY O UT