TDK SWS1000L-36

SWS600/1000L Series
Single Output Low Profile Power Supplies
Features
u Low Cost
u Low Profile
u Active Power Factor Correction
u Universal Input (85 - 265VAC)
u Input Transient Protected IEC61000-4
u Low Acoustical noise
u Medical Certifications (SWS1000L)
u Global safety Approvals
u Variable speed fan
Key Market Segments & Applications
Specifications
Model
Input Voltage range
Inrush Current (115 / 230VAC)
Power Factor
Input Current (100/200VAC)
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Parallel Connection
Remote On/Off (CNT)
Voltage Programming
(1)
DC Good & Fan Fail Signal
Auxiliary Output
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage(One minute)
A
A
V
ms
mA
°C
°C
-
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Immunity
Safety Agency Certification
Conducted & Radiated EMI
Weight (Typ)
Size (WxHxD)
Warranty
g
in
yrs
SWS600L
SWS1000L
85 - 265VAC (47 - 63Hz) or 120 - 350VDC
20 / 40
Meets EN61000-3-2 Class A
7.1 / 3.6 (3.3V: 5 / 2.5)
12 / 6
<0.02%/°C
>105%, Constant current style
125% -145%
Yes, cycle AC or Remote On/Off to reset
20ms at 115/230VAC
<0.75mA
100µA at 115VAC 60Hz(2)
Yes
Yes
Yes
Yes
Yes, open collector output
12V 0.1A
Green LED = On
-40°C start up. -20 to 74°C, derating linearly to 50% load above 50°C
-40 to +85°C
20 - 90% RH operating, 10 - 95%RH non operating
Variable speed internal fan
Input to Ground 2kVAC, Input to Output 3kVAC,
Input to Ground 2kVAC, Input to Output 4kVAC,
Output to Ground 500VAC, Output to CNT 100VAC Output to Ground 500VAC, Output to CNT 100VAC
>50M at 25C & 70%RH, Output to Ground 500VDC
MIL-STD-810F 514.5 Cat. 4,10
MIL-STD-810F 516.5 Procedure I, VI
EN61000-4-2, -3, -4, -5, -6, -8, -11
UL, CSA, EN60950-1, UL60601-1 (1000W only), IEC61010-1 (600W only), EN50178, CE Mark
EN55011 / EN55022-B, FCC Class B
1600
2300
2.4 x 4.72 x 7.48”
2.4 x 5.91 x 9.45”
Three Years
(1) 1-6V program voltage input to adjust output 20-120% (typical) of nominal. See instruction manual for details & models with this feature.
(2) Worst case: <300µA at 264VAC, 63Hz (Normal Condition); <500µA (Single Fault Condition).
1-800-526-2324 • www.us.tdk-lambda.com/lp/
99
Disclaimer: us.tdk-lambda.com/lp/legal.htm
SWS600/1000L Series
Model Selector
Model
SWS600L-3
SWS1000L-3
SWS600L-5
SWS1000L-5
SWS600L-12
SWS1000L-12
SWS600L-15
SWS1000L-15
SWS600L-24
SWS1000L-24
SWS600L-36
SWS1000L-36
SWS600L-48
SWS1000L-48
SWS600L-60
SWS1000L-60
Voltage
3.3V
3.3V
5V
5V
12V
12V
15V
15V
24V
24V
36V
36V
48V
48V
60V
60V
Adjust
Range
2.64 - 3.96V
2.64 - 3.96V
4 - 6V
4 - 6V
9.6 - 14.4V
9.6 - 14.4V
12 - 19.5V
12 - 19.5V
19.2 - 28.8V
19.2 - 28.8V
28.8 - 43.2V
28.8 - 43.2V
38.4 - 56V
38.4 - 56V
48 - 66V
48 - 66V
Curr.
(A)
120A
200A
120A
200A
53A
88A
43A
70A
27A (31A)4
44A (51A)4
18A
29A
13A (15A)4
22A (25A)4
10A
17A
Max
Pwr
(W)
396W
660W
600W
1000W
636W
1056W
645W
1050W
648W(744W)
1056W(1224W)
648W
1044W
624W(720W)
1056W(1200W)
600W
1020W
Max
Reg
(mV)
30
30
30
30
72
72
90
90
144
144
216
216
288
288
360
360
Load
Reg
(mV)
20
20
20
20
48
48
60
60
96
96
144
144
192
192
240
240
Line
Noise
(mV)
120
120
120
120
150
150
150
150
150
150
200
200
200
200
200
200
Ripple
Eff.(3)
(typ)%
70 / 72
74 / 76
75 / 77
79 / 81
79 / 82
82 / 84
79 / 82
82 / 84
81 / 84
84 / 86
82 / 84
84 / 86
82 / 84
84 / 86
82 / 84
84 / 86
Notes: (3) 115 / 230VAC
(4) Peak current and power possible at 170-265VAC input, 10s max, 35% duty cycle
SWS600L Outline Drawing
Other Industrial Products
SWS
HWS
ZWS
DLP, DPP, DSP
LS
50 - 300W Single Output
15 - 1800W Single output, high reliability
5 - 240W pcb style single, output
10 - 480W DIN Rail mount
25 - 200W Single output, low cost
1-800-526-2324 • www.us.tdk-lambda.com/lp/
For Additional Information, please visit
us.tdk-lambda.com/lp/products/sws-series.htm
100
Revision B1: Apr 2012