FCI FG10A02

Mechanical Dimensions
Description
FG10A01~07
"A" suffix
"C" suffix
"D" suffix
TO-220AB
Features
Mechanical Data
Low forward voltage drop
High current capability
High reliability
High surge current capability
High temperature soldering guaranteed:
260℃/10 seconds .16”,(4.06mm) from case
Cases: TO-220AB molded plastic
Epoxy: UL 94V-0 rate flame retardant
Terminals: Leads solderable per MIL-STD202, Method 208 guaranteed
Polarity: As marked
Weight: 2.24 grams
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol FG
FG
FG
FG
FG
FG
FG Units
Type Number
10A01 10A02 10A0310A0410A05 10A06 10A07
50 100 200 400 600 800 1000 V
Maximum Recurrent Peak Reverse Voltage
VRRM
35
70 140 280 420 560 700
V
Maximum RMS Voltage
VRMS
50 100 200 400 600 800 1000 V
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Rectified
Current .375”(9.5mm) Lead Length
@TC = 100℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@5.0A
Maximum DC Reverse Current @ TC=25℃
at Rated DC Blocking Voltage
Typical Junction Capacitance ( Note 1)
I(AV)
10.0
A
IFSM
125
A
VF
1.1
V
IR
5.0
uA
30
pF
3.0
℃/W
- 65 to + 150
Operating and Storage Temperature Range
TJ ,TSTG
℃
Notes: 1. Measured at 1 MHz and Applied Reverse Voltage of 4.0 Volts D.C.
2. Thermal Resistance from Junction to Case Mounted on Heatsink size 2” x 3” x 0.25”
Al-Plate
Typical Thermal Resistance (Note 2)
Cj
RθJC
RATINGS AND CHARACTERISTIC CURVES (GP1001 THRU GP1007)
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
SURGE CURRENT
175
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT. (A)
12
10
8
Single Phase
Half Wave 60Hz
Resistive of
Inductive Load
6
4
150
125
100
8.3ms Single Half Sine Wave
JEDEC Method
75
50
25
2
0
50
100
0
150
1
2
5
o
CASE TEMPERATURE. ( C)
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER LEG
400
100
200
INSTANTANEOUS REVERSE CURRENT. ( A)
40
40
20
10
4
2
1
Tj=25oC
Pulse Width=300 s
1% Duty Cycle
0.4
0.2
0.1
10
Tj=125 0C
4
2
1.0
Tj=25 0C
.4
.2
.6
.8
1.0
1.2
1.4
1.6
1.8
.1
2.0
FORWARD VOLTAGE. (V)
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
FIG.5- TYPICAL JUNCTION CAPACITANCE
120
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
100
100
80
60
40
f=10 MHz
Vsig 50Mvp-p
Tj=25 0C
20
0
0.1
0.5
1.0
4
10
40
REVERSE VOLTAGE. (V)
100
400
1000