XPPOWER VCP05US05_13

ACDC
5 Watts
VCP Series
xppower.com
•
Low Cost
•
Universal AC Input
•
Output Voltage from 5 to 15 V
•
PCB Mount
•
Class II Construction
•
EN55022 Class B Emissions
•
No Load Input Power <0.3 W
B R A N D
Specification
Input
General
•
•
•
•
•
•
•
90-264 VAC
47-63 Hz
0.2 A max at 90 VAC
40 A max at 240 VAC, cold start at 25 °C
EN61000-3-2, class A
<0.3 W
Internal T1.6A/250 V fuse in line
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
See table
±5% at 50% load
No minimum load required
2 s max
100 ms typical
5 ms typical at full load and 115 VAC
±0.5% max
2% max, 0-100% load
10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
See table
See table
120-180%, auto recovery
Trip and restart (hiccup mode)
0.2 %/˚C
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Output
Efficiency
Isolation
Switching Frequency
MTBF
•
•
•
•
See table
3000 VAC Input to Output
60 kHz typical
250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • 0 ˚C to +70 ˚C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 10-90% RH, non-condensing
Storage Temperature • -20 ˚C to +80 ˚C
Shock
• Able to survive 1 m drop onto concrete on
each of 6 axes
Vibration
• 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
•
•
•
•
Radiated Immunity
EFT/Burst
Surge
•
•
•
Conducted Immunity
Magnetic Field
Dips & Interruptions
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4kV contact, ±8kV air,
Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, level 2, Perf Criteria A
EN61000-4-5 installation class 3,
Perf Criteria A
EN61000-4-6, 3 V, Perf Criteria A
EN61000-4-8, 1 A/m, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60950-1, cUL60950-1, IEC60950-1
Output Power
Output Voltage(2)
Output Current
Ripple & Noise(1)
OVP Setting(3)
Efficiency(4)
5.0 W
4.8 W
4.5 W
5.0 V
12.0 V
15.0 V
1.0 A
0.4 A
0.3 A
150 mV
150 mV
150 mV
10.0 V
20.0 V
25.0 V
69%
69%
69%
Model Number
VCP05US05†^
VCP05US12†^
VCP05US15†^
Notes
1. Measured at DC output connector using 20 MHz bandwidth and 0.1 µF ceramic capacitor in parallel with 10 µF electrolytic capacitor placed at connector terminals
2. Other voltages between 3.0 V and 15.0 V are available, consult sales for details.
3. Typical trip point.
4. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input.
† Available from Farnell & element14. See page 28.
^ Available from Newark. See page 28.
Mechanical Details
2.3 (58.5)
1.15 (29.25)
1.05 (26.7)
0.75 (19.1)
0.59
(15)
0.19
(4.8)
1
1.4
(35.5)
4
TOP VIEW
0.05
(1.2)
0.62
(15.8)
5
2
3
1.01 (25.7)
0.4
(10)
0.67
(17.02)
0.06 (1.60)
0.99 (25.2)
ø 0.040
(ø1.00)
0.15 (3.80)
0.18 (4.50)
ø 0.070
(ø1.80)
Pin
Designation
1
No connection
2
Neutral
3
Live
4
Output -VE
5
Output +VE
Notes
1. All dimensions are in inches (mm).
2. Weight: 0.04 lbs (20 g) approx.
3. Tolerance: x.x = ±0.04 (x.x = ±1.0), x.xx = ±0.02 (x.xx = ±0.5)
15-May-12
ACDC
VCP05
Models and Ratings