Product data sheet
variable speed drive ATV12 - 0.75kW - 1hp 200..240V - 1ph - with heat sink
Range of product
Altivar 12
Product or component
Variable speed drive
Product destination
Asynchronous motors
Product specific
Simple machine
Assembly style
With heat sink
Component name
EMC filter
Built-in fan
Network number of
Single phase
[Us] rated supply
200...240 V (- 15...10 %)
Motor power kW
0.75 kW
Motor power hp
1 hp
Communication port
Line current
8.5 A, 0...1 kA
Speed range
Transient overtorque
150...170 % of nominal motor torque
Asynchronous motor
control profile
Sensorless flux vector control with PWM type motor
control signal
IP degree of protection
IP20 without blanking plate on upper part
Supply frequency
50/60 Hz (+/- 5 %)
Continuous output current
4.2 A at 4 kHz
Maximum transient current
6.3 A for 60 s
Speed drive output frequency
0...400 Hz
Nominal switching frequency
4 kHz
Switching frequency
2...16 kHz adjustable
4...16 kHz with derating factor
Braking torque
Upto 150 % of nominal motor torque with braking resistor at high inertia
Upto 70 % of nominal motor torque without braking resistor
Regulation loop
Factory-set with the speed loop stability and gain
Motor slip compensation
Preset in factory
Prospective line Isc
<= 1 kA
Output voltage
200...240 V triphase
Electrical connection
L1, L2, L3, U, V, W, PA, PC terminal 3.5 mm² (AWG 12)
Tightening torque
0.8 N.m
Electrical between power and control
Internal supply for logic inputs 24 V DC, voltage limits 20.4...27.6 V 100 mA for
overload and short-circuit protection
Internal supply for reference potentiometer 5 V DC, voltage limits 4.75...5.25 V 10
mA for overload and short-circuit protection
Analogue input number
Analogue input type
AI1 configurable current 0...20 mA, impedance 250 Ohm
AI1 configurable voltage 0...10 V, impedance 30 kOhm
AI1 configurable voltage 0...5 V, impedance 30 kOhm
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Sampling duration
< 10 ms for analogue input
20 ms, tolerance +/- 1 ms for logic input
Linearity error
+/- 0.3 ms for analogue input
Discrete input number
Discrete input type
LI1...LI4 programmable 24 V, voltage limits 18...30 V
Discrete input logic
Negative by program, >= 16 V (state 0), < 10 V (state 1)
Positive, 0...< 5 V (state 0), >= 11 V (state 1)
Discrete output number
Discrete output type
(CLO) transmitter
(LO1) open collector
(R1A, R1B, R1C) logic relay 1 C/O
Minimum switching current
5 mA at 24 V DC for logic relay
Maximum switching current
2 A at 250 V AC inductive load cos phi = 0.4, L/R= L/R = 7 ms for logic relay
2 A at 30 V DC inductive load cos phi = 0.4, L/R= L/R = 7 ms for logic relay
3 A at 250 V AC resistive load cos phi = 1, L/R= L/R = 0 ms for logic relay
4 A at 30 V DC resistive load cos phi = 1, L/R= L/R = 0 ms for logic relay
Acceleration and deceleration ramps
Linear from 0 to 999.9 s
Braking to standstill
By DC injection, 0.1...30 s
Protection type
Line supply overvoltage
Line supply undervoltage
Modbus serial link failure
Overcurrent between output phases and earth
Overheating protection
Safety for no network three-phase
Short-circuit between motor phases
Thermal protection
Insulation resistance
>= 500 MOhm
Frequency resolution
Analog input converter A/D, 10 bits
Display unit 0.1 Hz
Time constant
20 ms, tolerance +/- 1 ms for reference change
Operating position
Vertical +/- 10 degree
Product weight
0.8 kg
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test (level 3) conforming to EN/IEC 61000-4-5
Electrical fast transient/burst immunity test (level 4) conforming to EN/IEC
Electrostatic discharge immunity test (level 3) conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances (level 3) conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test (level 3) conforming
to EN/IEC 61000-4-3
EN/IEC 61800-3
Product certifications
Vibration resistance
1 gn (f = 13...200 Hz conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3...13 Hz)drive unmounted on symmetrical DIN rail
conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity
5...95 % without condensation conforming to IEC 60068-2-3
5...95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for storage
-25...70 °C
Ambient air temperature for operation
-10...40 °C with protective cover from the top of the drive removed
40...60 °C with current derating 2.2 % per °C
Operating altitude
> 1000...2000 m with derating 1 % per 100 m
1000 m without derating
RoHS EUR status
RoHS EUR conformity date