OMRON G3M-203P-UTU-1-4DC5

Solid State Relays
G3M
Zero Cross Models Added to Compact,
Low-cost G3M Series
• 3 and 5A single in-line package SSR
• Thin design for high-density PCB applications.
• DC input-AC output for up to a 5-A load.
• Certified by UL, CSA, and VDE.
Ordering Information
To order: Select the part number and add the desired input voltage rating. (e.g., G3M-203PL DC5)
Isolation
Input terminal
pitch
Phototriac 7.62 mm
Zero cross
function
Indicator
Rated output load
(Applicable output load)
Rated input voltage Model
Yes
No
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC
G3M-203P
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC
G3M-205P
12 VDC
24 VDC
No
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC
G3M-203PL
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC
G3M-205PL
12 VDC
24 VDC
5.08 mm
Yes
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC
G3M-203P-4
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC
G3M-205P-4
12 VDC
24 VDC
No
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
5 VDC
G3M-203PL-4
12 VDC
24 VDC
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5 VDC
G3M-205PL-4
12 VDC
24 VDC
Note: 1. All models have UL and CSA approvals.
2. TÜV Marking is available for 3 amp versions with reinforced insulation by inserting “-UTU” in place of “-US” in the part number
Example: G3M-203P-UTU-1-4 DC12
3. G3M-205P(L)-VD-1, with reinforced insulation, is approved by UL, CSA and VDE
Solid State Relays
G3M
407
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input
Rated voltage
Operating voltage
Impedance
Voltage levels
Must operate voltage
5 VDC
300 Ω ±20%
4 to 6 VDC
4 VDC max.
12 VDC
9.6 to 14.4 VDC
800 Ω ±20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
1.6 kΩ ±20%
19.2 VDC max.
Must release voltage
1 VDC min.
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Model
Rated voltage
Applicable load
Load voltage range
G3M-203P(L)(-4)
100 to 240 VAC
75 to 264 VAC
G3M-205P(L)(-4)
Load current
0.1 to 3 A
Inrush current
45 A (60 Hz, 1 cycle)
0.1 to 5 A
■ Characteristics
Item
G3M-203P(L)(-4)
G3M-205P(L)(-4)
Operate time
1 ms max. (1/2 of load power source cycle + 1 ms max. for G3M-203P, G3M-205P)
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
1.5 mA (at 200 VAC)
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2 (approx. 100G)
Ambient temperature
Operating:
–30°C to 80°C (with no icing or condensation)
Storage:
–30°C to 100°C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 15 g
Approx. 25 g
■ Approvals
UL Recognized (File No. E64562) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C
Input Voltage
SSR Type
Load Rating
5, 12, 24 VDC
With Suffixes 203 and
US or UTU
3 A, 250 VAC, Resistive
750 W, 250 VAC Tungsten
1.5 A FLA / 9 A LRA, 250 VAC
With Suffix 205
5 A, 250 VAC, Resistive
1,250 W, 250 VAC Tungsten
2.5 A FLA / 15 A LRA, 250 VAC
408
Solid State Relays
G3M
Engineering Data
Load Current vs. Ambient Temperature
Inrush Current Immunity
Non-repetitive
Reduce the current to 1/2 or less if the
G3M is in repetitive operation.
6
50
G3M-205P(L)(-4)
Inrush peak current (A)
Load current (A)
5
4
G3M-203P(L)(-4)
3
2
1.5
1
40
G3M-203P(L)(-4)
G3M-205P(L)(-4)
30
20
10
0.5
0
−30 −20
0
20 25
40
60
80
0
100
10
30 50
Ambient temperature (°C)
100 200
500 1,000
5,000
Energized time (ms)
Load Current vs. Ambient Temperature (Close Mounting)
G3M-205 Series (5-A Load)
Y direction
5
4
5
4
3
3
2
Z direction
6
Load current (A)
6
Load current (A)
Load current (A)
X direction
5
4
3
2.5A L=20.37 mm
2.0A L=20.37 mm
6
2.5A L=20.37 mm
2
1.8A L=12.7 mm
2
1.8A L=12.7 mm
1
0.8A L=7.62 mm
1
0.8A L=7.62 mm
1.5A L=12.7 mm
1
0
−30
0.6A L=7.62 mm
−20
0
20 25
40
60
80
Ambient temperature (°C)
100
0
−30
−20
0
20 25
40
60
80
100
0
−30
−20
0
20 25
40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
L
L
L L
Top
L L
Top
Top
10
10
3
Bottom
Bottom
Bottom
3
10
• Thirty Relays are soldered to the PCB at each given spacing.
• Continuous power.
Solid State Relays
G3M
409
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3M-203P(L)-4
PCB Dimensions
(Bottom View)
9 max.
40 max.
Four, 1.2 dia. holes
2.54
20 max.
4
3
2
1
4±2
4
7.62
12.7
2.54
0.7
10.16
4
(4)
3
1.5
"-4" type
G3M-205P(L)-4
7.6±0.2
40 max.
Terminal Arrangement
(Bottom View)
Input voltage
25 max.
4
3
2
4±2
7.62
12.7
10.16
Load
0.7
0.4
1.65
*Input terminal pitch for models ending in "-4" is 5.08 mm.
Precautions
Protective Element
No overvoltage absorption element is built in. Therefore, if the G3M
is connected to an inductive load, be sure to connect the overvoltage
absorption element.
Solid State Relays
G3M
Load power
supply
1
(5.08)*
410
1
0.4
(5.08)*
4
2
Input
Load
MEMO
Solid State Relays
G3M
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1b
Solid State Relays
09/11
G3M