CUI MD-80S

date
03/29/2012
page
1 of 4
SERIES: MD-XXS │ DESCRIPTION: MINI DIN CONNECTOR
FEATURES
• PCB mount
• right angle
• non-shielded
RoHS
PART NUMBER KEY
MD - XX S
Base Number
Pin Options
30 = 3 pins
40 = 4 pins
50 = 5 pins
60 = 6 pins
70 = 7 pins
80 = 8 pins
90 = 9 pins
SPECIFICATIONS
parameter
conditions/description
min
rated input voltage
rated input current
typ
max
100
12
at 100 Vac
at 12 Vdc
contact resistance
insulation resistance
at 250 Vdc
voltage withstand
for 1 minute
units
Vac
Vdc
1
2
A
A
30
mΩ
250
Vac
50
MΩ
insertion force
1
4.5
kg
withdrawl force
0.8
3
kg
operating temperature
-40
life
85
1,000
cui.com
°C
cycles
CUI Inc │ SERIES: MD-XXS │ DESCRIPTION: MINI DIN CONNECTOR
date 03/29/2012 │ page 2 of 4
MECHANICAL DRAWINGS
units: mm[inches]
TOLERANCE: ±0.2mm
MATERIAL
PLATING
earth terminal
brass
tin
contact terminals (1~8)
phosphor bronze
silver
housing
PBT
12.4 0.488
14.0 0.551
1.8 0.071
8.0 0.315
8
6
7
5
4
2
3
12.8 0.504
12.3 0.484
1
6.5 0.256
0.3 0.012
(TYP)
3.5 0.138
(TYP)
0.4 0.016
(TYP)
0.75 0.030
(TYP)
0.4 0.016
0.75 0.030
(TYP)
2.0 0.079
10.00 0.394
5.00 0.197
1.50 0.059
(2 PLCS)
4.7 0.185
8.5 0.335
(4 PLCS)
11.0 0.433
(4 PLCS)
5
8
2
7
1
3
4
6
9.10 0.358
(2 PLCS)
1.00 0.039
0.1 (4 PLCS)
0.9 0.035
2.6 0.102
6.8 0.268
(2 PLCS)
BOTTOM VIEW
MD-30S
MD-40S
4
3
2
2
1
MD-50S
5
3
4
3
1
2
1
2.2X0.7
2.2X0.7
2.2X0.7
4.7 0.185
4.7 0.185
8.5 0.335
(2 PLCS)
8.5 0.335
(2 PLCS)
2
1
0.9 0.035
(3 PLCS)
+0.1
-0.0
11.0 0.433
3
0.9 0.035
6.8 0.268
PCB LAYOUT
TOP VIEW
0.9 0.035
(4 PLCS)
+0.1
-0.0
1
2
3
4
11.0 0.433
(2 PLCS)
6.8 0.268
(2 PLCS)
PCB LAYOUT
TOP VIEW
cui.com
4.7 0.185
8.5 0.335
(3 PLCS)
2
0.9 0.035
(5 PLCS)
+0.1
-0.0
1
4
3
11.0 0.433
(2 PLCS)
5
1.3 0.051
6.8 0.268
(2 PLCS)
PCB LAYOUT
TOP VIEW
CUI Inc │ SERIES: MD-XXS │ DESCRIPTION: MINI DIN CONNECTOR
MD-60S
6
date 03/29/2012 │ page 3 of 4
MD-70S
5
4
2
6
7
3
8
5
4
2
0.9 0.035
(6 PLCS)
+0.1
-0.0
4.7 0.185
4.7 0.185
8.5 0.335
(4 PLCS)
8.5 0.335
(4 PLCS)
3
1
2
11.0 0.433
(2 PLCS)
4
5
3
0.9 0.035
(7 PLCS)
+0.1
-0.0
6
2.6 0.102
6.8 0.268
(2 PLCS)
5
1
2
6
4
11.0 0.433
(3 PLCS)
3
0.9 0.035
(8 PLCS)
+0.1
-0.0
7
0.9 0.035
6
1
4
2
7
11.0 0.433
(4 PLCS)
5
8
0.9 0.035
2.6 0.102
2.6 0.102
PCB LAYOUT
TOP VIEW
3
1
2.2X0.7
4.7 0.185
8.5 0.335
(4 PLCS)
6
4
1
2.2X0.7
2.2X0.7
7
5
3
2
1
MD-80S
6.8 0.268
(2 PLCS)
6.8 0.268
(2 PLCS)
PCB LAYOUT
TOP VIEW
PCB LAYOUT
TOP VIEW
MD-90S
12.5 0.492
14.0 0.551
9
10.6 0.417
7
8
6
12.9 0.508
1.9 0.075
5
4
2
1
3
6.5 0.256
0.2 0.008
3.8 0.150
(TYP)
11.0 0.433
2.2X0.7
5.0 0.197
4.7 0.185
11.0 0.433
(5 PLCS)
4.7 0.185
8.5 0.335
(4 PLCS)
3
7
4
5
8.5 0.335
6
2
1
11.0 0.433
8
0.9 0.035
+0.1
-0.0
(9 PLCS)
6
9
9
1.3 0.051
0.7 0.028
2
8
1
5
3
4
1.0 0.039
0.1 (4 PLCS)
4.0 0.157
8.0 0.315
(2 PLCS)
0.7 0.028
1.3 0.051
4.0 0.157
8.0 0.315
(2 PLCS)
PCB LAYOUT
TOP VIEW
cui.com
7
CUI Inc │ SERIES: MD-XXS │ DESCRIPTION: MINI DIN CONNECTOR
date 03/29/2012 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
02/23/2006
1.01
new template applied
02/16/2012
1.02
housing updates
03/29/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.