CYPRESS CY7C9689-AI

CY7C9689
TAXI™ Compatible HOTLink® Transceiver
Framer
Deserializer
Decoder
4B/5B, 5B/6B
Control
HOTLink devices are ideal for a variety of applications where
parallel interfaces can be replaced with high-speed, point-topoint serial links. Some applications include interconnecting
workstations, backplanes, servers, mass storage, and video
transmission equipment.
Serial Link
Serializer
Data
Transmit
Encoder
4B/5B, 5B/6B
Status
Serial Link
Transmit
Data
Control
CY7C9689
CY7C9689
FIFO
Transmit
System Host
Data
Receive
FIFO
Receive
The transmit section of the CY7C9689 HOTLink can be configured to accept either 8- or 10-bit data characters on each
clock cycle, and stores the parallel data into an internal synchronous Transmit FIFO. Data is read from the Transmit FIFO
and is encoded using embedded 4B/5B or 5B/6B encoders to
The TTL parallel I/O interface may be configured as either a
FIFO (configurable for depth expansion through external
FIFOs) or as a pipeline register extender. The FIFO configurations are optimized for transport of time-independent (asynchronous) 8- or 10-bit character-oriented data across a link. A
Built-In Self-Test (BIST) pattern generator and checker allows
for testing of the high-speed serial data paths in both the transmit and receive sections, and across the interconnecting links.
Status
System Host
The CY7C9689 HOTLink Transceiver is a point-to-point communications building block allowing the transfer of data over
high-speed serial links (optical fiber, balanced, and unbalanced copper transmission lines) at speeds ranging between
50 and 200 MBaud. The transmit section accepts parallel data
of selectable widths and converts it to serial data, while the
receiver section accepts serial data and converts it to parallel
data of selectable widths. Figure 1 illustrates typical connections between two independent host systems and corresponding CY7C9689 parts. The CY7C9689 provides enhanced
technology, increased functionality, a higher level of integration, higher data rates, and lower power dissipation over the
AMD AM7968/7969 TAXIchip products.
Transmit
FIFO
Functional Description
The integrated 4B/5B and 5B/6B encoder/decoder may be bypassed (disabled) for systems that present externally encoded
or scrambled data at the parallel interface. With the encoder
bypassed, the pre-encoded parallel data stream is converted
to and from a serial NRZI stream. The embedded FIFOs may
also be bypassed (disabled) to create a reference-locked serial transmission link. For those systems requiring even greater
FIFO storage capability, external FIFOs may be directly coupled to the CY7C9689 through the parallel interface without
the need for additional glue-logic.
Receive
FIFO
•
•
•
•
•
Encoder
4B/5B, 5B/6B
•
•
•
The receive section of the CY7C9689 HOTLink accepts a serial bit-stream from one of two PECL compatible differential
line receivers and, using a completely integrated PLL Clock
Synchronizer, recovers the timing information necessary for
data reconstruction. The recovered bit stream is converted
from NRZI to NRZ, deserialized, framed into characters, 4B/5B
or 5B/6B decoded, and checked for transmission errors. The
recovered 8- or 10-bit decoded characters are then written to
an internal Receive FIFO, and presented to the destination
host system.
Decoder
4B/5B, 5B/6B
•
•
Second-generation HOTLink® technology
AMD™ AM7968/7969 TAXIchip™ compatible
8-bit 4B/5B or 10-bit 5B/6B NRZI encoded data transport
10-bit or 12-bit NRZI pre-encoded (bypass) data
transport
Synchronous TTL parallel interface
Embedded/Bypassable 256 character Transmit and
Receive FIFOs
50-to-200 MBaud serial signaling rate
Internal PLLs with no external PLL components
Dual differential PECL-compatible serial inputs and
outputs
Compatible with fiber-optic modules and copper cables
Built-In Self-Test (BIST) for link testing
Link Quality Indicator
Single +5.0V ±10%supply
100-pin TQFP
Deserializer
Framer
•
•
•
•
improve its serial transmission characteristics. These encoded
characters are then serialized, converted to NRZI, and output
from two PECL-compatible differential transmission line drivers at a bit-rate of either 10 or 20 times the input reference
clock in 8-bit (or 10-bit bypass) mode, or 12 or 24 times the
reference clock in 10-bit (or 12-bit bypass) mode.
Serializer
Features
Receive
Data
Figure 1. HOTLink System Connections
Cypress Semiconductor Corporation
•
3901 North First Street
•
San Jose
•
CA 95134
•
408-943-2600
June 14, 2000
CY7C9689
CY7C9689 TAXI HOTLink Transceiver Logic Block Diagram
TX
STATUS
TXDATA/TXCMD CONTROL
TXCLK
MODE
REFCLK
10
8
RX
STATUS
RXDATA/RXCMD
RXCLK
13
13
3
4
Mode
Control
Output Register
MUX
MUX
Output Register
Input Register
Flags
Mode
Receive
FIFO
Flags
Transmit
FIFO
CONTROL
CE
TXEN
RXEN
TXHALT
TXRST
RXRST
RFEN
TXBISTEN
RXBISTEN
RESET
Transmit
PLL Clock
Multiplier
MUX
Pipeline Register
MUX
Pipeline Register
Receive
Control
State
Machine
BIST LFSR
4B/5B, 5B/6B Encoder
BIST LFSR
4B/5B, 5B/6B Decoder
Transmit
Control
State
Machine
MUX
Serial Shifter
MODE
RANGESEL
SPDSEL
RXMODE[1:0]
FIFOBYP
EXTFIFO
ENCBYP
BYTE8/10
TEST
Clock
Divider
Deserializer
Framer
Receive
Clock/Data
Recovery
Bit Clock
Bit Clock
RXSTATUS
LFI
RXEMPTY
RXHALF
RXFULL
TX STATUS
TXEMPTY
TXHALF
TXFULL
Routing Matrix
Signal
Validation
DLB
OUTA
INA
OUTB
CURSETB
CURSETA
2
INB
A/B
CARDET
CY7C9689
VSSA
RXBISTEN
CURSETB
VSSA
VDDA
OUTB+
OUTB–
VSSA
VSSA
INB–
INB+
VDDA
VDDA
OUTA+
OUTA–
VSSA
VSSA
INA–
INA+
VDDA
VDDA
CURSETA
VDDA
VSSA
CARDET
Pin Configuration
TEST
1
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
75
A/B
2
74
RANGESEL
LFI
3
73
RFEN
VSS
4
72
TXFULL
DLB
5
71
CE
VLTN
6
70
TXHALF
TXBISTEN
7
69
RXEN
RXCLK
8
68
TXCLK
TXHALT
9
67
RXRST
RXFULL
10
66
VSS
VSS
11
65
RXSC/D
REFCLK
12
64
VDD
VSS
13
63
VSS
VDD
14
62
VDD
VSS
15
61
RXDATA[0]
TXRST
16
60
TXEMPTY
VDD
17
59
RXDATA[1]
CY7C9689
SPDSEL
3
BYTE8/10
EXTFIFO
RXDATA[3]
RXDATA[4]
51
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
TXDATA[8]/TXCMD[3]
25
RXDATA[5]
VSS
RXMODE[0]
TXDATA[7]
52
RXDATA[6]
24
TXDATA[6]
RXDATA[2]
RXMODE[1]
RXDATA[7]
53
TXDATA[5]
23
VSS
TXDATA[9]/TXCMD[2]
RXCMD[1]
VSS
54
VSS
22
TXDATA[4]
VDD
TXDATA[0]
VDD
55
TXDATA[3]
21
RXDATA[8/RXCMD[3]
TXCMD[0]
RXEMPTY
TXDATA[2]
56
RXDATA[9]/RXCMD[2]
20
TXDATA[1]
VSS
TXSC/D
RXCMD[0]
TXCMD[1]
57
FIFOBYP
58
19
VSS
18
ENCBYP
TXEN
RXHALF
RESET
CY7C9689
(
Pin Descriptions
Pin
Name
I/O Characteristics
Signal Description
Transmit Path Signals
68
TXCLK
44, 42, TXDATA[7:0]
40, 36,
34, 32,
30, 22
TTL clock input
Internal Pull-Up
Transmit FIFO Clock.
Used to sample all Transmit FIFO and related interface signals.
TTL input, sampled on Parallel Transmit DATA Input.
TXCLK¦ or REFCLK¦ When selected (CE=LOW and TXEN = asserted), information on these inputs
Internal Pull-Up
is processed as DATA when TXSC/D is LOW and ignored otherwise. When the
encoder is bypassed (ENCBYP is LOW), TXDATA[7:0] functions as the least
significant eight bits of the 10- or 12-bit pre-encoded transmit character.
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed
(FIFOBYP is LOW) these inputs are captured on the rising edge of REFCLK.
54, 46 TXDATA[9:8]/
TXCMD[2:3]
TTL input, sampled on Parallel Transmit DATA or COMMAND Input.
TXCLK¦ or REFCLK¦ When selected, BYTE8/10 is HIGH, and the encoder is enabled (ENCBYP is
Internal Pull-Up
HIGH), information on these inputs are processed as TXCMD[2:3] if TXSC/D is
HIGH and ignored otherwise.
When selected, BYTE8/10 is LOW, and the encoder is enabled (ENCBYP is
HIGH), information on these inputs are processed as TXDATA[9:8] if TXSC/D
is LOW and ignored otherwise.
When the encoder is bypassed (ENCBYP is LOW), TXDATA[9:8] functions as
the 9th and 10th bits of the 10- or 12-bit pre-encoded transmit character.
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed
(FIFOBYP is LOW), these inputs are captured on the rising edge of REFCLK.
58, 56 TXCMD[1:0]
TTL input, sampled on Parallel Transmit COMMAND Input.
TXCLK¦ or REFCLK¦ When selected and the encoder is enabled (ENCBYP is HIGH), information on
Internal Pull-Up
these inputs is processed as a COMMAND when TXSC/D is HIGH and ignored
otherwise.
When BYTE8/10 is HIGH and the encoder is bypassed (ENCBYP is LOW), the
TXCMD[1:0] inputs are ignored.
When BYTE8/10 is LOW and when the encoder is bypassed (ENCBYP is LOW),
the TXCMD[1:0] inputs function as the 11th and 12th (MSB) bits of the 12-bit
pre-encoded transmit character.
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed
(FIFOBYP is LOW), these inputs are sampled on the rising edge of REFCLK.
20
TXSC/D
TTL input, sampled on COMMAND or DATA input selector.
TXCLK¦ or REFCLK¦ When selected, BYTE8/10 is HIGH, and the encoder is enabled (ENCBYP is
Internal Pull-Up
HIGH), this input selects if the DATA or COMMAND inputs are processed. If
TXSC/D is HIGH, the value on TXCMD[3:0] is captured as one of sixteen possible COMMANDs, and the data on the TXDATA[7:0] bits are ignored. If TXSC/D
is LOW, the information on TXDATA[7:0] is captured as one of 256 possible 8bit DATA values, and the information on the TXCMD[3:0] bus is ignored.
When BYTE8/10 is LOW and the encoder is enabled (ENCBYP is HIGH) this
input selects if the DATA or COMMAND inputs are processed. If TXSC/D is
HIGH, the information on TXCMD[1:0] is captured as one of four possible COMMANDs, and the information on the TXDATA[9:0] bits are ignored. If TXSC/D is
LOW, the information on TXDATA[9:0] is captured as one of 1024 possible 10bit DATA values, and the information on the TXCMD[1:0] bus is ignored.
When the encoder is bypassed (ENCBYP is LOW) TXSC/D is ignored
4
CY7C9689
Pin Descriptions (continued)
Pin
18
Name
TXEN
I/O Characteristics
Signal Description
TTL input, sampled on Transmit Enable.
TXCLK¦ or REFCLK¦ TXEN is sampled on the rising edge of the TXCLK or REFCLK input and enables
Internal Pull-Up
parallel data bus write operations (when selected). The device is selected when
TXEN is asserted during a clock cycle immediately following one in which CE
is sampled LOW.
Depending on the level on EXTFIFO, the asserted state for TXEN can be active
HIGH or active LOW. If EXTFIFO is LOW, then TXEN is active LOW and data
is captured on the same clock cycle where TXEN is sampled LOW. If EXTFIFO
is HIGH, then TXEN is active HIGH and data is captured on the clock cycle
following any clock edge when TXEN is sampled HIGH.
7
16
TXBISTEN
TXRST
TTL input,
asynchronous
Internal Pull-Up
Transmitter BIST Enable.
When TXBISTEN is LOW, the transmitter generates a 511-character repeating
sequence that can be used to validate link integrity. This 4B/5B BIST sequence
is generated regardless of the state of other configuration inputs. The transmitter returns to normal operation when TXBISTEN is HIGH. All Transmit FIFO
read operations are suspended when BIST is active.
TTL input, sampled on Reset Transmit FIFO.
TXCLK¦
When the Transmit FIFO is enabled (FIFOBYP is HIGH), TXEN is deasserted,
Internal Pull-Up
CE is asserted (LOW), and TXRST is sampled LOW by TXCLK for seven cycles,
the Transmit FIFO begins its internal reset process. The Transmit FIFO TXFULL
flag is asserted and the host interface counter and address pointer are zeroed.
This reset propagates to the serial transmit side, any remaining counters and
pointers. The TXFULL flag is asserted until both sides of the Transmit FIFO have
reset. While TXRST remains asserted, the Transmit FIFO remains in reset and
the TXFULL output remains asserted.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXRST is ignored.
9
TXHALT
TTL input, sampled on Transmitter Halt Control Input.
TXCLK¦
When TXHALT is asserted LOW, transmission of data is suspended and the
Internal Pull-Up
HOTLink TAXI transmits SYNC characters. When TXHALT is deasserted HIGH,
normal data processing proceeds.
If the Transmit FIFO is enabled (FIFOBYP is HIGH), the interface is allowed to
continue loading data into the Transmit FIFO while TXHALT is asserted.
72
TXFULL
Three-state TTL out- Transmit FIFO Full Status Flag.
put, changes following When the Transmit FIFO is enabled (FIFOBYP is HIGH) and its flags are driven
TXCLK¦ or REFCLK¦ (CE is LOW), TXFULL is asserted when four or fewer characters can be written
to the HOTLink Transmit FIFO. If a Transmit FIFO reset has been initiated
(TXRST was sampled asserted for a minimum of seven TXCLK cycles),
TXFULL is asserted to enforce the full/unavailable status of the Transmit FIFO
during reset.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), the TXFULL output
changes after the rising edge of REFCLK. TXFULL is asserted when the transmitter is BUSY (not accepting a new data or command characters) and deasserted when new characters can be accepted.
When the Transmit FIFO is bypassed and RANGESEL is HIGH or SPDSEL is
LOW, TXFULL toggles at the character rate to provide a character rate reference
control-indication since REFCLK is operating at twice of the data rate.
The asserted state of this output (HIGH or LOW) is determined by the state of
the EXTFIFO input. When EXTFIFO is LOW, TXFULL is active LOW. When
EXTFIFO is HIGH, TXFULL is active HIGH.
5
CY7C9689
Pin Descriptions (continued)
Pin
70
Name
TXHALF
I/O Characteristics
Signal Description
Three-state TTL out- Transmit FIFO Half-full Status Flag.
put, changes following When the Transmit FIFO is enabled (FIFOBYP is HIGH and CE is LOW)
TXCLK¦
TXHALF is asserted when the HOTLink Transmit FIFO is Š half full (128 characters is half full). If a Transmit FIFO reset has been initiated (TXRST was
sampled asserted for a minimum of seven TXCLK cycles), TXHALF is asserted
to enforce the full/unavailable status of the Transmit FIFO during reset.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXHALF remains
deasserted, having no logical function.
TXHALF is forced to the High-Z state only during a “full-chip” reset (i.e., while
RESET is LOW).
60
TXEMPTY
Three-state TTL out- Transmit FIFO Empty Status Flag.
put, changes following When the Transmit FIFO is enabled (FIFOBYP is HIGH and CE is LOW),
TXCLK¦ or REFCLK¦ TXEMPTY is asserted when the HOTLink Transmit FIFO has no data to forward
to the encoder. If a Transmit FIFO reset has been initiated (TXRST was sampled
asserted for a minimum of seven TXCLK cycles), TXEMPTY is deasserted and
remains deasserted until the Transmit FIFO reset operation is complete.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXEMPTY is asserted to indicate that the transmitter can accept data. TXEMPTY is also used as
a BIST progress indicator when TXBISTEN is asserted.
When TXBISTEN is asserted LOW, TXEMPTY becomes the transmit BIST-loop
counter indicator (regardless of the logic state of FIFOBYP). In this mode
TXEMPTY is asserted for one TXCLK or REFCLK period at the end of each
transmitted BIST sequence.
NOTE: During BIST operations, when the Transmit FIFO is enabled (FIFOBYP
is HIGH), it is necessary to keep TXCLK operating, even though no data is
loaded into the Transmit FIFO and TXEN is never asserted, to allow the
TXEMPTY flag to respond to the BIST state changes.
The asserted state of this output (HIGH or LOW) is determined by the state of
the EXTFIFO input. When EXTFIFO is LOW, TXEMPTY is active LOW. When
EXTFIFO is HIGH, TXEMPTY is active HIGH.
If CE is sampled asserted (LOW), TXEMPTY is driven to an active state. If CE
is sampled deasserted (HIGH), TXEMPTY is placed into a High-Z state.
Receive Path Signals
8
RXCLK
41, 43, RXDATA[7:0]
45, 47,
48, 53,
59,61
Bidirectional TTL clock Receive Clock.
Internal Pull-Up
When the Receive FIFO is enabled (FIFOBYP is HIGH), this clock is the Receive
interface input clock and is used to control Receive FIFO read and reset, operations. When the Receive FIFO is bypassed (FIFOBYP is LOW), this clock
becomes the recovered Receive PLL character clock output which runs continuously at the character rate.
Three-state TTL out- Parallel Receive DATA Outputs.
put, changes following When the decoder is enabled (ENCBYP is HIGH), the low-order eight bits of
RXCLK¦
the decoded DATA character are presented on the RXDATA[7:0] outputs.
COMMAND characters, when they are received, do not disturb these outputs.
When the decoder is bypassed, the low order eight bits of the non-decoded
character are presented on the RXDATA[7:0] outputs.
When the Receive FIFO is disabled (FIFOBYP is LOW), these outputs change
on the rising edge of the RXCLK output. When the Receive FIFO is enabled
(FIFOBYP is HIGH), these outputs change on the rising edge of RXCLK input.
RXEN is the three-state control for RXDATA[7:0].
6
CY7C9689
Pin Descriptions (continued)
Pin
Name
31, 33 RXDATA[9:8]/
RXCMD[2:3]
I/O Characteristics
Signal Description
Three-state TTL out- Parallel Receive DATA or COMMAND Output.
put, changes following When BYTE8/10 is HIGH and the decoder is enabled (ENCBYP is HIGH) these
RXCLK¦
outputs reflects the value for the most recently received RXCMD[2:3].
When BYTE8/10 is LOW and the decoder is enabled (ENCBYP is HIGH) these
outputs reflects the value for the most recently received RXDATA[9:8].
When the decoder is bypassed (ENCBYP is LOW), RXDATA[9:8] functions as
the 9th and 10th bits of the 10- or 12-bit non-decoded receive character.
When the Receive FIFO is disabled (FIFOBYP is LOW), these outputs change
on the rising edge of the RXCLK output. When the Receive FIFO is enabled
(FIFOBYP is HIGH), these outputs change on the rising edge of the RXCLK
input.
RXEN is a three-state control for RXDATA[9:8]/RXCMD[2:3].
23, 29 RXCMD[1:0]
Three-state TTL out- Parallel Receive COMMAND Outputs.
put, changes following When the decoder is enabled (ENCBYP is HIGH) these outputs reflect the value
RXCLK¦
for the most recently received RXCMD[1:0].
When BYTE8/10 is HIGH and the decoder is bypassed (ENCBYP is LOW),
these outputs have no meaning and are driven LOW.
When BYTE8/10 is LOW and the decoder is bypassed (ENCBYP is LOW),
RXCMD[1:0] functions as the 11th and 12th (MSB) bits of the 12-bit nondecoded receive character.
When the Receive FIFO is disabled (FIFOBYP is LOW), this output changes on
the rising edge of the RXCLK output. When the Receive FIFO is enabled
(FIFOBYP is HIGH), these outputs change on the rising edge of the RXCLK
input.
RXEN is a three-state control for RXCMD[1:0].
69
RXEN
TTL input, sampled
on RXCLK¦
Internal Pull-Up
Receive Enable Input.
RXEN is a three-state control for the parallel data bus read operations. RXEN
is sampled on the rising edge of the RXCLK input (or output) and enables
parallel data bus read operations (when selected). The device is selected when
RXEN is asserted during an RXCLK cycle immediately following one in which
CE is sampled LOW. The parallel data pins are driven to active levels after the
rising edge of RXCLK. When RXEN is de-asserted (ending the selection) the
parallel data pins are High-Z after the rising edge of RXCLK.
Depending on the level on EXTFIFO, this signal can be active HIGH or active
LOW. If EXTFIFO is LOW, then RXEN is active LOW. If EXTFIFO is HIGH, then
RXEN is active HIGH. Data is delivered on the clock cycle following any clock
edge when RXEN is active.
65
RXSC/D
Three-state TTL out- COMMAND or DATA Output Indicator.
put, changes following When BYTE8/10 is HIGH and the decoder is enabled (ENCBYP is HIGH), this
RXCLK¦
output indicates which group of outputs have been updated. If RXSC/D is HIGH,
RXCMD[3:0] contains a new COMMAND. The DATA on the RXDATA[7:0] pins
remain unchanged. If RXSC/D is LOW, RXDATA[7:0] contains a new DATA character. The COMMAND output on RXCMD[3:0] remain unchanged.
When BYTE8/10 is LOW and the decoder is enabled (ENCBYP is HIGH), this
output indicates which group of outputs have been updated. If RXSC/D is HIGH,
RXCMD[1:0] contains a new COMMAND and the DATA on the RXDATA[9:0]
remain unchanged. If RXSC/D is LOW, RXDATA[9:0] contains a new DATA character and the COMMAND output on RXCMD[1:0] remain unchanged.
When the decoder is bypassed (ENCBYP is LOW) RXSC/D is not used and
may be left unconnected.
RXEN is a three-state control for RXSC/D.
7
CY7C9689
Pin Descriptions (continued)
Pin
6
Name
VLTN
I/O Characteristics
Three-state TTL output, changes following
RXCLK¦
Internal Pull-Down
Signal Description
Code Rule Violation Detected.
VLTN is asserted in response to detection of a 4B/5B or 5B/6B character that
does not meet the coding rules of these characters. When VLTN is asserted,
the values on the output DATA and COMMAND buses remain unchanged. VLTN
remains asserted for one RXCLK period.
VLTN is used to report character mismatches when RXBISTEN is driven LOW.
VLTN is driven LOW when the decoder is bypassed (ENCBYP is LOW).
RXEN is a three-state control for VLTN.
67
RXRST
TTL input, sampled on Receive FIFO Reset. Active LOW.
RXCLK¦
When the Receive FIFO is enabled (FIFOBYP is HIGH), RXEN is deasserted,
Internal Pull-Up
CE is asserted (LOW), and RXRST is sampled while asserted (LOW) by RXCLK
for seven cycles, the Receive FIFO begins its internal reset process.
Once the reset operation is started, the RXEMPTY flag is asserted and the
interface counters and address pointer are zeroed. The reset operation proceeds to clear out the internal write pointers and counters. The RXEMPTY
output remains asserted through the reset operation and remains asserted until
new data is written to the Receive FIFO. While RXRST remains asserted, the
Receive FIFO remains in reset and cannot accept received characters.
When the Receive FIFO is bypassed (FIFOBYP is LOW), RXRST is ignored.
24, 25 RXMODE[1:0] Static control input
TTL levels
Normally wired HIGH
or LOW
Receiver Discard Policy Mode Select.
• 00b—allows all characters to be written into the Receive FIFO or output to
the Receive data bus
• 01b—discards all JK or LM sync characters except the “last” one of a string
of sync characters. Single sync characters in a data stream are included in
the data written into the Receive FIFO.
• 1Xb—discards all JK or LM sync characters. The data stream written into
the Receive FIFO does not include sync characters.
77
Receiver BIST Enable. Active LOW.
RXBISTEN
TTL input,
asynchronous
Internal Pull-Up
When LOW, the receiver is configured to perform a character-for-character
match of the incoming data stream with a 511-character BIST sequence. The
result of character mismatches are indicated on the VLTN pin. Completion of
each 511-character BIST loop is accompanied by an assertion pulse on the
RXFULL flag.
The state of ENCBYP, FIFOBYP, and BYTE8/10 have no effect on BIST
operation.
73
RFEN
TTL input,
asynchronous
Internal Pull-Up
Reframe Enable.
Used to control when the framer is allowed to adjust the character boundaries
based on detection of one or more framing characters in the data stream.
When framing is enabled (RFEN is HIGH) the receive framer realigns the serial
stream to the incoming 10-bit JK sync character (if BYTE8/10 is HIGH) or the
12-bit LM sync character (if BYTE8/10 is LOW). Framing is disabled when RFEN
is LOW. The deassertion of RFEN freezes the character boundary relationship
between the serial stream and character clock. RFEN is an asynchronous input,
sampled by the internal Receive PLL character clock.
8
CY7C9689
Pin Descriptions (continued)
Pin
10
Name
RXFULL
I/O Characteristics
Signal Description
Three-state TTL out- Receive FIFO Full Flag.
put, changes following When the Receive FIFO is enabled (FIFOBYP is HIGH) and its flags are driven
RXCLK¦
(CE is LOW), RXFULL is asserted when space is available for four or fewer
characters to be written to the HOTLink Receive FIFO. If the RXCLK input is not
continuous or the FIFO is accessed at a rate slower than data is being received,
RXFULL may also indicate that some data has been lost because of FIFO
overflow.
When the Receive FIFO is bypassed (FIFOBYP is LOW), RXFULL is deasserted to indicate that valid data may be present. RXFULL is also used as a BIST
progress indicator, and pulses once every pass through the 511 character BIST
loop.
When RXBISTEN is asserted (LOW), RXFULL becomes the receive BIST loop
progress indicator (regardless of the logic state of FIFOBYP). While RXBISTEN
is asserted, RXFULL is asserted until the receiver detects the start of the BIST
pattern. Then RXFULL is deasserted for the duration of the BIST pattern, pulsing asserted for one RXCLK period on the last symbol of each BIST loop. If 14
of 28 consecutive symbols are received in error, RXFULL returns to the asserted
state until the start of a BIST pattern is again detected.
The asserted state of this output (HIGH or LOW) is determined by the state of
the EXTFIFO input. When EXTFIFO is LOW, RXFULL is active LOW. When
EXTFIFO is HIGH, RXFULL is active HIGH.
19
RXHALF
Three-state TTL out- Receive FIFO Half-full Flag.
put, changes following When the Receive FIFO is enabled (FIFOBYP is HIGH and CE is LOW)
RXCLK¦
RXHALF is asserted when the HOTLink Receive FIFO is Š half full (128 characters is half full). If a Receive FIFO reset has been initiated (RXRST was
sampled asserted for a minimum of seven RXCLK cycles), RXHALF is deasserted to enforce the empty/unavailable status of the Receive FIFO during reset.
If FIFOBYP is LOW, RXHALF remains deasserted having no logical function.
RXHALF is forced to the High-Z state only during a “full-chip” reset (i.e., while
RESET is LOW).
21
RXEMPTY
Three-state TTL out- Receive FIFO Empty Flag.
put, changes following When the Receive FIFO is enabled (FIFOBYP is HIGH) and its flags are driven
RXCLK¦
(CE is LOW), RXEMPTY is asserted when the HOTLink Receive FIFO has no
data to forward to the parallel interface. If a Receive FIFO reset has been initiated (RXRST was sampled asserted for a minimum of seven RXCLK cycles),
RXEMPTY is asserted to enforce the empty/unavailable status of the Receive
FIFO during reset.
Any read operation occurring when RXEMPTY is asserted results in no change
in the FIFO status, and the data from the last valid read remains on the RXDATA
bus. When the Receive FIFO is bypassed but the decoder is enabled,
RXEMPTY is used as a valid data indicator. When deasserted it indicates that
valid data is present at the RXDATA or RXCMD outputs as indicated by RXSC/D.
When asserted it indicates that a SYNC character (JK or LM) is present on the
RXCMD output pins. When the Receive FIFO is bypassed (FIFOBYP is LOW),
RXEMPTY is deasserted whenever data is ready.
The asserted state of this output (HIGH or LOW) is determined by the state of
the EXTFIFO input. When EXTFIFO is LOW, RXEMPTY is active LOW. When
EXTFIFO is HIGH, RXEMPTY is active HIGH.
9
CY7C9689
Pin Descriptions (continued)
Pin
Name
I/O Characteristics
Signal Description
Control Signals
71
CE
TTL input sampled on Chip Enable Input. Active LOW.
TXCLK¦, RXCLK¦, or When CE is asserted and sampled LOW by RXCLK, the Receive FIFO status
REFCLK¦
flags are driven to their active states. When this input is deasserted and sampled
by RXCLK, the Receive FIFO status flags are placed in a High-Z state.
When CE has been sampled LOW and RXEN changes from deasserted to
asserted and is sampled by RXCLK, the RXSC/D, RXDATA[7:0], RXDATA[9:8]/
RXCMD[2:3] and VLTN output drivers are enabled and go to their driven levels.
These pins remain driven until RXEN is sampled deasserted.
When the Transmit FIFO is enabled (FIFOBYP is HIGH), and CE is asserted
and sampled by TXCLK, the Transmit FIFO status flags are driven to their active
states. When this input is deasserted and sampled by TXCLK, the Transmit
FIFO status flags are placed in a High-Z state.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), and CE is asserted
and sampled by REFCLK, the Transmit FIFO status flags are driven to their
active states. When this input is deasserted and sampled by REFCLK, the
Transmit FIFO status flags are placed in a High-Z state.
When the Transmit FIFO is enabled (FIFOBYP is HIGH), CE has been sampled
LOW, and TXEN changes from deasserted to asserted and is sampled by
TXCLK, the TXSC/D, TXDATA[7:0], TXDATA[9:8]/RXCMD[2:3], and
TXCMD[1:0] inputs are sampled and passed to the Transmit FIFO. These inputs
are sampled on all consecutive TXCLK cycles until TXEN is sampled
deasserted.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), CE has been sampled
LOW, and TXEN changes from deasserted to asserted and is sampled by
REFCLK, the TXSC/D, TXDATA[7:0], TXDATA[9:8]/RXCMD[2:3], and
TXCMD[1:0] inputs are sampled and passed to the encoder or serializer as
directed by other control inputs. These inputs are sampled on all consecutive
REFCLK cycles until TXEN is sampled deasserted.
12
REFCLK
TTL clock input
PLL Frequency Reference Clock.
This clock input is used as the timing reference for the transmit and receive
PLLs. When the Transmit FIFO is bypassed (FIFOBYP is HIGH), REFCLK is
also used as the clock for the parallel transmit interface.
75
74
SPDSEL
RANGESEL
Static control input
TTL levels
Normally wired HIGH
or LOW
Speed Select.
Static control input
TTL levels
Normally wired HIGH
or LOW
Range Select.
Used to select from one of two operating serial rates for the CY7C9689. When
SPDSEL is HIGH, the signaling rate is between 100 and 200 MBaud. When
LOW, the signaling rate is between 50 and 100 MBaud. Used in combination
with RANGESEL and BYTE8/10 to configure the VCO multipliers and dividers.
Selects the proper prescaler for the REFCLK input. If RANGESEL is LOW, the
REFCLK input is passed directly to the Transmit PLL clock multiplier. If
RANGESEL is HIGH, REFLCK is divided by two before being sent to the Transmit PLL multiplier.
When the Transmit FIFO is bypassed (FIFOBYP is LOW), with RANGESEL
HIGH or SPDSEL LOW, TXFULL toggles at half the REFCLK rate to provide a
character rate indication, and to show when data can be accepted.
51
RESET
Asynchronous
TTL input
Master Reset for Internal Logic.
Pulsed LOW for one or more REFCLK cycles.
10
CY7C9689
Pin Descriptions (continued)
Pin
28
Name
FIFOBYP
I/O Characteristics
Static control input
TTL levels
Normally wired HIGH
or LOW
Signal Description
FIFO Bypass Enable.
When asserted, the Transmit and Receive FIFOs are bypassed. In this mode
TXCLK is not used. Instead all transmit data must be synchronous to REFCLK.
Transmit FIFO status flags are synchronized to REFCLK. All received data is
synchronous to RXCLK output. Receive FIFO status flags are synchronized to
RXCLK (the recovered Receive PLL character clock).
When not asserted, the Transmit and Receive FIFOs are enabled. In this mode
all Transmit FIFO writes are synchronized to TXCLK, and all Receive FIFO
reads are synchronous to the RXCLK input.
50
BYTE8/10
Static control input
TTL levels
Normally wired HIGH
or LOW
8/10-bit Parallel Data Size Select.
When set for 8-bit data (BYTE8/10 is HIGH) and the encoder is enabled
(ENCBYP is HIGH), 8-bit DATA characters and 4-bit COMMAND characters are
captured at the TXDATA[7:0] or TXCMD[3:0] inputs (selected by the TXSC/D
input) and passed to the Transmit FIFO (if enabled) and encoder. Received
characters are decoded, passed through the Receive FIFO (if enabled) and
presented at either the RXDATA[7:0] or RXCMD[3:0] outputs and indicated by
the RXSC/D output.
When set for 8-bit data (BYTE8/10 is HIGH) and the encoder is bypassed
(ENCBYP is LOW), the internal data paths are set for 10-bit characters. Each
received character is presented to the Receive FIFO (if enabled) and is passed
to the RXDATA[9:0] outputs.
When set for 10-bit data (BYTE8/10 is LOW) and the encoder is enabled
(ENCBYP is HIGH), 10-bit DATA characters and 2-bit COMMAND characters
are captured at the TXDATA[9:0] or TXCMD[1:0] inputs (selected by the TXSC/D
input) and passed to the Transmit FIFO (if enabled) and encoder. Received
characters are decoded, passed through the Receive FIFO (if enabled) and
presented at either the RXDATA[9:0] or RXCMD[1:0] outputs and indicated by
the RXSC/D output.
When set for 10-bit data (BYTE8/10 is LOW) and the encoder is bypassed
(ENCBYP is LOW), the internal clock data paths are set for 12-bit characters.
Each received character is presented to the Receive FIFO (if enabled) and is
passed to the RXDATA[9:0] and the RXCMD[1:0] outputs.
49
EXTFIFO
Static control input
TTL levels
Normally wired HIGH
or LOW
External FIFO Mode.
EXTFIFO modifies the active state of the RXEN and TXEN inputs and the timing
of the Transmitter and Receiver data buses. When configured for external FIFOs
(EXTFIFO is HIGH), TXEN is assumed to be driven by the empty flag of an
attached CY7C42X5 FIFO, and RXEN is assumed to be driven by the almost
full flag of an attached CY7C42X5 FIFO. In this mode the active data transition
is in the clock following the clock edge that “enables” the data bus.
When not configured for external FIFOs (EXTFIFO is LOW), TXEN is assumed
to be driven as a pipeline register and RXEN is assumed to be driven by a
controller for a pipeline register. In this mode the active data transition is within
the same clock as the clock edge that “enables” the data bus.
EXTFIFO also modifies the output state of the Receive and Transmit FIFO flags.
When configured for external FIFOs (EXTFIFO is HIGH), the Full and Empty
FIFO flags are active HIGH (the Half full flag is always active LOW). When not
configured for external FIFOs (EXTFIFO is LOW), all of the FIFO flags are active
LOW.
27
ENCBYP
Static control input
TTL levels
Normally wired HIGH
or LOW
Enable Encoder Bypass Mode.
When asserted, both the encoder and decoder are bypassed. Data is transmitted without 4B/5B or 5B/6B encoding (but with NRZI encoding), LSB first. Received data are presented as parallel characters to the parallel interface without
decoding.
When deasserted, data is passed through both the encoder in the Transmit path
and the decoder in the Receive path.
11
CY7C9689
Pin Descriptions (continued)
Pin
Name
I/O Characteristics
Signal Description
Analog I/O and Control
89, 90, OUTA±
81, 82 OUTB±
PECL compatible
differential output
Differential Serial Data Outputs.
94, 93, INA±
86, 85 INB±
PECL compatible
differential input
Differential Serial Data Inputs.
97
Analog
CURSETA
These PECL-compatible differential outputs are capable of driving terminated
transmission lines or commercial fiber-optic transmitter modules. To minimize
the power dissipation of unused outputs, the outputs should be left unconnected
and the associated CURSETA or CURSETB should be connected to VDD.
These inputs accept the serial data stream for deserialization and decoding.
Only one serial stream at a time may be fed to the receive PLL to extract the
data content. This stream is selected using the A/B input.
Current-set Resistor Input for OUTA±.
A precision resistor is connected between this input and a clean ground to set
the output differential amplitude and currents for the OUTA± differential driver.
78
CURSETB
Analog
Current-set Resistor Input for OUTB±.
A precision resistor is connected between this input and a clean ground to set
the output differential amplitude and currents for the OUTB± differential driver.
100
CARDET
PECL input,
asynchronous
Carrier Detect Input.
Input A or Input B Selector.
Used to allow an external device to signify a valid signal is being presented to
the high-speed PECL input buffers, as is typical on an Optical Module. When
CARDET is deasserted LOW, the LFI indicator asserts LOW signifying a Link
Fault. This input can be tied HIGH for copper media applications.
2
A/B
Asynchronous
TTL input
3
LFI
Three-state TTL out- Link Fault Indication Output. Active LOW.
put, changes following LFI changes synchronous with RXCLK. This output is driven LOW when the
RXCLK¦
serial link currently selected by A/B is not suitable for data recovery. This could
be because:
When HIGH, input INA± is selected, when LOW, INB± is selected.
1. Serial Data Amplitude is below acceptable levels
2. Input transition density is not sufficient for PLL clock recovery
3. Input Data stream is outside an acceptable frequency range of operation
4. CARDET is LOW
5
DLB
Asynchronous
TTL input
Diagnostic Loop Back Selector.
When DLB is LOW, LOOP Mode is OFF. Output of the transmitter shifter is
routed to both OUTA± and OUTB± and the serial input selected by A/B is routed
to the receive PLL for data recovery.
When DLB is HIGH, Diagnostic Loopback is Enabled. Output of the transmitter
serial data is routed to the receive PLL for data recovery. Primarily used for
System Diagnostic test. The serial inputs are ignored and OUTA± and OUTB±
are both active.
1
TEST
Asynchronous
TTL input normally
wired HIGH
Test Mode Select.
Used to force the part into a diagnostic test mode used for factory ATE test. This
input must be tied HIGH during normal operation.
Power
80, 87, VDDA
88, 95,
96, 98
Power for PECL-compatible I/O signals and internal circuits.
76, 79, VSSA
83, 84,
91, 92,
99
Ground for PECL-compatible I/O signals and internal circuits.
12
CY7C9689
Pin Descriptions (continued)
Pin
Name
I/O Characteristics
Signal Description
14, 17, VDD
35, 55,
62, 64
Power for TTL I/O signals and internal circuits.
4,11, VSS
13, 15,
26, 37,
38, 39,
52, 57,
63, 66
Ground for TTL I/O signals and internal circuits.
CY7C9689 HOTLink Operation
data bus width. Actual clock rate depends on data rate as well
as RANGESEL and SPDSEL logic levels.
Overview
Both asynchronous and synchronous interface operations
support user control over the logical sense of the FIFO status
flags. Full and empty flags on both the transmitter and receiver
can be active HIGH or active LOW. This facilitates interfacing
with existing control logic or external FIFOs with minimal or no
external glue logic.
The CY7C9689 is designed to move parallel data across both
short and long distances with minimal overhead or host system intervention. This is accomplished by converting the parallel characters into a serial bit-stream, transmitting these serial bits at high speed, and converting the received serial bits
back into the original parallel data format.
Encoder
The CY7C9689 offers a large feature set, allowing it to be used
in a wide range of host systems. Some of the of configuration
options are
• AMD TAXIchip 4B/5B & 5B/6B compatible encoder/decoder
• AMD TAXIchip compatible serial link
• AMD TAXIchip parallel COMMAND and DATA I/O bus
architecture
• 8-bit or 10-bit character size
• User-definable data packet or frame structure
• Two-octave data rate range
• Asynchronous (FIFOed) or synchronous data interface
• Embedded or bypassable FIFO data storage
• Encoded or non-encoded
• Multi-PHY capability
This flexibility allows the CY7C9689 to meet the data transport
needs of almost any system.
Data from the host interface or Transmit FIFO is next passed
to an Encoder block. The CY7C9689 contains both 4B/5B and
5B/6B encoders that are used to improve the serial transport
characteristics of the data. For those systems that contain their
own encoder or scrambler, this Encoder may be bypassed.
Serializer/Line Driver
The data from the Encoder is passed to a Serializer. This Serializer operates at 10 or 12 times the character rate. With the
internal FIFOs enabled, REFCLK can run at 1x, 2x, or 4x the
character rate. With the FIFOs bypassed, REFCLK can operate at 1x or 2x the character rate. The serialized data is output
in NRZI format from two PECL-compatible differential line drivers configured to drive transmission lines or optical modules.
Receive Data Interface
Line Receiver/Deserializer/Framer
Serial data is received at one of two PECL-compatible differential line receivers. The data is passed to both a Clock and
Data Recovery Phase Locked Loop (PLL) and to a Deserializer that converts NRZI serial data into NRZ parallel characters.
The Framer adjusts the boundaries of these characters to
match those of the original transmitted characters.
Transmit Data Path
Transmit Data Interface/Transmit Data FIFO
The transmit data interface to the host system is configurable
as either an asynchronous buffered (FIFOed) parallel interface
or as a synchronous pipeline register. The bus itself can be
configured for operation with either 8-bit or 10-bit character
widths.
Decoder
The parallel characters are passed through a pair of 5B/4B or
6B/5B decoders and returned to their original form. For systems that make use of external decoding or descrambling, the
decoder may be bypassed.
When configured for asynchronous operation (where the hostbus interface clock operates asynchronous to the serial character and bit stream clocks), the host interface becomes that
of a synchronous FIFO clocked by TXCLK. In this configuration an internal 256-character Transmit FIFO is enabled that
allows the host interface to be written at any rate from DC to
50 MHz.
Receive Data Interface/Receive Data FIFO
Data from the decoder is passed either to a synchronous Receive FIFO or is passed directly to the output register. The
output register can be configured for either 8-bit character or
10-bit character operation.
When configured for synchronous operation, the transmit interface is clocked by REFCLK and operates synchronous to
the internal character and bit-stream clocks. The input register
can be written at either 1/10th or 1/12th the serial bit rate. This
interface can be clocked at up to 40 MHz when configured for
8-bit data width, and up to 33 MHz when configured for 10-bit
When configured for an asynchronous buffered (FIFOed) interface, the data is passed through a 256-character Receive
FIFO that allows data to be read at any rate from DC to 50
13
CY7C9689
1, and list the functional names of these different signals. Note
that the function of several of these signals changes in different
operating modes. The logical sense of the enable and FIFO
flag signals depends on the intended interface convention and
is set by the EXTFIFO pin.
MHz. When configured for synchronous operation (Receive
FIFO is bypassed) data is clocked out of the Receive Output
register at up to 20 MHz when configured for 8-bit characters,
or 16.67 MHz when configured for 10-bit characters. The receive interface is also configurable for FIFO flags with either
HIGH or LOW status indication
The transmit interface supports both synchronous and asynchronous clocking modes, each supporting both UTOPIA and
Cascade timing models. The selection of the specific clocking
mode is determined by the RANGESEL and SPDSEL inputs
and the FIFO Bypass (FIFOBYP) signal.
Oscillator Speed Selection
The CY7C9689 is designed to operate over a two-octave
range of serial signaling rates, covering the 50- to 200-MBaud
range. To cover this wide range, the PLLs are configured into
various sub-regions using the SPDSEL and RANGESEL inputs, and to a limited extent the BYTE8/10 input. These inputs
are used to configure the various prescalers and clock dividers
used with the transmit and receive PLLs.
TXDATA[7:0]
TXCMD[3:0]
REFCLK
TXSC/D
CY7C9689 TAXI HOTLink Transceiver
Block Diagram Description
TXEN
CE
TXCLK
12
Transmit Input/Output Register
Transmit Input Register
The CY7C9689 provides a synchronous interface for data and
command inputs, instead of the TAXI’s asynchronous strobed
interface. The Transmit Input Register, shown in Figure 2, captures the data and command to be processed by the HOTLink
Transmitter, and allows the input timing to be made compatible
with asynchronous or synchronous host system buses. These
buses can take the form of external FIFOs, state machines, or
other control structures. Data and command present on the
TXDATA[9:0] and TXSC/D inputs are captured at the rising
edge of the selected sample clock. The transmit data bus bitassignments vary depending on the data encoding and buswidth selected. These bus bit-assignments are shown in Table
14
To Encoder
Block
Transmit FIFO
Figure 2. Transmit Input Register
Table 1. Transmit Input Bus Signal Map
Transmit Encoder Mode[1]
TXDATA Bus Input Bit
Encoded 8-bit
Character Stream[2]
TXSC/D
TXSC/D
Pre-encoded 10-bit
Character Stream
Encoded 10-bit
Character Stream[3]
Pre-encoded 12-bit
Character Stream
TXSC/D
TXDATA[0]
TXD[0][5]
TXD[1]
TXDATA[1]
TXD[1]
TXDATA[2]
TXD[2]
TXDATA[2]
TXD[2]
TXDATA[3]
TXDATA[3]
TXD[3]
TXDATA[3]
TXD[3]
TXDATA[4]
TXDATA[4]
TXD[4]
TXDATA[4]
TXD[4]
TXDATA[5]
TXDATA[5]
TXD[5]
TXDATA[5]
TXD[5]
TXDATA[6]
TXDATA[6]
TXD[6]
TXDATA[6]
TXD[6]
TXDATA[7]
TXDATA[7]
TXD[7]
TXDATA[7]
TXD[7]
TXDATA[0]
TXDATA[0]
TXDATA[1]
TXDATA[1]
TXDATA[2]
TXD[0]
[4]
TXDATA[8]/TXCMD[3]
TXCMD[3]
TXD[8]
TXDATA[8]
TXD[8]
TXDATA[9]/TXCMD[2]
TXCMD[2]
TXD[9]
TXDATA[9][3]
TXD[9]
TXCMD[1]
TXCMD[1]
TXCMD[1]
TXD[10][5]
TXCMD[0]
TXCMD[0]
TXCMD[0]
TXD[11]
Notes:
1. All open cells are ignored.
2. When ENCBYP is HIGH and BYTE8/10 is HIGH, transmitted bit order is the encoded form (MSB to LSB) of TXDATA[7,6,5,4] and TXDATA[3,2,1,0] or
TXCMD[3,2,1,0] as selected by TXSC/D.
3. When ENCBYP is HIGH and BYTE8/10 is LOW, transmitted bit order is the encoded form (MSB to LSB) of TXDATA[8,7,6,5,4] and TXDATA[9,3,2,1,0] or
TXCMD[1,0] as selected by TXSC/D.
4. When ENCBYP is LOW and BYTE8/10 is HIGH, the transmitted bit order is (LSB to MSB) TXD[0,1,2,3,4,5,6,7,8,9].
5. When ENCBYP is LOW and BYTE8/10 is LOW, the transmitted bit order is (LSB to MSB) TXD[0,1,2,3,4,5,6,7,8,9,11,10].
14
CY7C9689
ed), data is captured in the transmit input register and stored
into the Transmit FIFO. All Transmit FIFO write operations are
clocked by TXCLK.
Synchronous Interface
Synchronous interface clocking operates the entire transmit
data path synchronous to REFCLK. It is enabled by connecting
FIFOBYP LOW to disable the internal FIFOs.
The Transmit FIFO presents Full, Half-Full, and Empty FIFO
flags. These flags are provided synchronous to TXCLK. When
the Transmit FIFO is enabled, it allows operation with a Mooretype external controlling state machine. When configured for
Cascade timing, the timing and active levels of these signals
are also designed to support direct expansion to Cypress
CY7C42x5 synchronous FIFOs.
Asynchronous Interface
Asynchronous interface clocking controls the writing of host
bus data into the Transmit FIFO. It is enabled by setting
FIFOBYP HIGH to enable the internal FIFOs. In these configurations, all writes to the Transmit Input Register, and associated transfers to the Transmit FIFO, are controlled by TXCLK.
The remainder of the transmit data path is clocked by REFCLK
or synthesized derivatives of REFCLK.
Regardless of bus width (8- or 10-bit characters) the Transmit
FIFO can be clocked at any rate from DC to 50 MHz. This gives
the Transmit FIFO a maximum bandwidth of 50 million characters per second. Since the serial outputs can only move 20
million characters per second at their fastest operating rate,
there is ample time to service multiple CY7C9689 HOTLinks
with a single controller.
Shared Bus Timing Model
The Shared Bus Timing Model allows multiple CY7C9689
transmitters to be accessed from a common host bus. It is
enabled by setting EXTFIFO LOW. In shared bus timing, the
TXEMPTY and TXFULL outputs and TXEN input are all active
LOW signals. If the CY7C9689 is addressed by asserting CE
LOW, it becomes “selected” when TXEN is asserted LOW. Following selection, data or command is written into the Transmit
FIFO on every clock cycle where TXEN remains LOW.
The read port of the Transmit FIFO is connected to a logic
block that performs data formatting and validation. All data
read operations from the Transmit FIFO are controlled by a
Transmit Control State Machine that operates synchronous to
REFCLK.
Cascade Timing Model
Encoder Block
The Cascade timing model is a variation of the shared bus
timing model. Here the TXEMPTY and TXFULL outputs, and
TXEN input, are all active HIGH signals. Cascade timing
makes use of the same selection sequences as shared bus
timing, but write data accesses use a delayed write. This delayed write is necessary to allow direct coupling to external
FIFOs, or to state machines that initiate a write operation one
clock cycle before the data is available on the bus.
The Encoder logic block performs two primary functions: encoding the data for serial transmission and generating BIST
(Built-In Self-Test) patterns to allow at-speed link and device
testing.
BIST LFSR
The Encoder logic block operates on data stored in a register.
This register accepts information directly from the Transmit
FIFO, the Transmit Input Register, the 10/8 Byte-Packer, or
from the Transmit Control State Machine when it inserts special characters into the data stream.
Cascade timing is enabled by setting EXTFIFO HIGH.
When used for FIFO depth expansion, Cascade timing allows
the size of the internal Transmit FIFO to be expanded to an
almost unlimited depth. It allows a CY7C42x5 series synchronous FIFO to be attached to the transmit interface without any
extra logic, as shown in Figure 3.
This same register is converted into a Linear Feedback Shift
Register (LFSR) when the Built-In Self-Test (BIST) pattern
generator is enabled (TXBISTEN is LOW). When enabled, this
LFSR generates a 511-character sequence that includes all
Data and Special Character codes, including the explicit violation symbols. This provides a predictable but pseudo-random
sequence that can be matched to an identical LFSR in the
Receiver.
Transmit FIFO
The Transmit FIFO is used to buffer data and command captured in the input register for later processing and transmission. This FIFO is sized to hold 256 14-bit characters. When
the Transmit FIFO is enabled, and a Transmit FIFO write is
enabled (the device is selected and TXEN is sampled assertCY7C42x5 FIFO
FF*
WEN*
D
TXCLK
FF*
WEN*
D
WCLK
Encoder
The data passed through the Transmit FIFO and pipeline register, or as received directly from the Transmit Input Register,
is seldom in a form suitable for transmission across a serial
link. The characters must usually be processed or transformed
to guarantee:
•a minimum transition density (to allow the serial receiver PLL
to extract a clock from the data stream)
•some way to allow the remote receiver to determine the correct character boundaries (framing).
The CY7C9689 contains an integrated 4B/5B encoder that accepts 8-bit data characters and converts these into 10-bit
transmission characters that have been optimized for transport
on serial communications links. This 4B/5B encoding scheme
is compliant with the ANSI X3T9.5 (FDDI) committee’s 4B/5B
code. The CY7C9689 also contains a 5B/6B encoder that accepts 10-bit data characters and converts these into 12-bit
transmission characters.
CY7C9689
EF*
TXEN
REN*
TXFULL
Q
TXDATA
TXSC/D
RCLK
TXCLK
“1”
EXTFIFO
Figure 3. External FIFO Depth Expansion of the CY7C9689
Transmit Data Path
15
CY7C9689
OUTB± receives its data from the Routing Matrix. These two
outputs (OUTA± and OUTB±) are capable of direct connection
to +5V optical modules, and can also directly drive DC- or ACcoupled transmission lines.
The 4B/5B, 5B/6B encoder can be bypassed for those systems
that operate with external 4B/5B or 5B/6B encoders or use
alternate forms of encoding or scrambling to ensure good
transmission characteristics. The complete encoding tables
are listed in Tables 7 and 8.
The PECL-compatible Output Drivers can be viewed as programmable current sources. The output voltage is determined
by the output current and the load impedance ZLOAD. The desired output voltage swing is therefore controlled by the current-set resistor RCURSET associated with that driver. Different
R CURSET values are required for different line impedance/amplitude combinations. The output swing is designed to center
around VDD-1.33V. Each output must be externally biased to
VDD-1.33V.
When the Encoder is enabled, the transmit data characters (as
passed through the Transmit FIFO and pipeline register) are converted to either a 10-bit or 12-bit Data symbol or a 10-bit or 12-bit
Command Character, depending upon the state of the TXSC/D input. If TXSC/D is HIGH, the data on the command inputs are encoded into Command Character as shown in Table 8. If TXSC/D is
LOW, the data inputs are encoded using the Data Character encoding in Table 7.
The 4B/5B, 5B/6B coding function of the Encoder can be bypassed for systems that include an external coder or scrambler
function as part of the controller or host system. This is performed by setting ENCBYP LOW. With the encoder bypassed,
each 10-bit or 12-bit character (as captured in the Transmit
Input Register) is passed directly to the Transmit Shifter (or
Transmit FIFO) without modification.
This differential output-swing can be specified two ways: either
as a peak-to-peak voltage into a single-end load, or as an absolute differential voltage into a differential load.
When specified into a single-ended load (one of the outputs
switching into a load), the single output will both source and
sink current as it changes between its HIGH and LOW levels.
The voltage difference between this HIGH level and LOW level
determine the peak-to-peak signal-swing of the output. This
amplitude relationship is controlled by the load impedance on
the driver, and by the resistance of the RCURSET resistor for
that driver, as listed in Eq. 1
Transmit Shifter
The Transmit Shifter accepts 10-bit (BYTE8/10 = HIGH) or 12bit (BYTE8/10 = LOW) parallel data from the Encoder block
once each character time, and shifts it out the serial interface
output buffers using a PLL-multiplied bit-clock with NRZI encoding. This bit-clock runs at 2.5, 5, or 10 times the REFCLK
rate (3, 6, or 12 times when BYTE8/10 is LOW) as selected by
RANGESEL and SPDSEL (see Table 3). Timing for the parallel
transfer is controlled by the counter and dividers in the Clock
Multiplier PLL and is not affected by signal levels or timing at
the input pins. Bits in each character are shifted out LSB first.
180 × Z LOAD
R CURS ET = -------------------------------V OPP
In Eq. 1, VOPP is the difference in voltage levels at one output
of the differential driver when that output is driving HIGH and
LOW, ZLOAD is that load seen by the one output when it is
sourcing and sinking current. With a known load impedance
and a desired signal swing, it is possible to calculate the value
of the associated CURSETA or CURSETB resistor that sets
this current.
Routing Matrix
The Routing Matrix is a precision multiplexor that allows local
diagnostic loopback. The signal routing for the transmit serial
outputs is controlled by the DLB input as listed in Table 2.
Unused differential output drivers should be left open, and can
reduce their power dissipation by connecting their respective
CURSETx input to VDD.
Table 2. Transmit Data Routing Matrix
DLB[0]
Eq. 1
Data Connections
Transmit PLL Clock Multiplier
0
TRANSMIT
SHIFTER
The Transmit PLL Clock Multiplier accepts an external clock at
the REFCLK input, and multiples that clock by 2.5, 5, or 10 (3,
6, or 12 when BYTE8/10 is LOW and the encoder is disabled)
to generate a bit-rate clock for use by the transmit shifter. It also
provides a character-rate clock used by the Transmit Controller
state machine.
OUTA
A/B
OUTB
INB
RECEIVE
PLL
INA
The clock multiplier PLL can accept a REFCLK input between
8 MHz and 40 MHz, however, this clock range is limited by the
operation mode of the CY7C9689 as selected by the SPDSEL
and RANGESEL inputs, and to a limited extent, by the
BYTE8/10 and FIFOBYP signals. The operating serial signalling rate and allowable range of REFCLK frequencies is listed
in Table 3.
1
TRANSMIT
SHIFTER
O UTA
A/B
OU TB
INB
RECEIVE
PLL
Transmit Control State Machine
INA
The Transmit Control State Machine responds to multiple inputs to control the data stream passed to the encoder. It operates in response to:
•the state of the FIFOBYP input
•the presence of data in the Transmit FIFO
•the contents of the Transmit FIFO
Serial Line Drivers
The serial interface PECL Output Drivers (ECL referenced to
+5V) are the transmission line drivers for the serial media.
OUTA± receives its data directly from the transmit shifter, while
16
CY7C9689
Table 3. Speed Select and Range Select Settings
SPDSEL
RANGESEL
Serial
Data Rate
(MBaud)
LOW
LOW
50–100
10–20
50–100
20–40
LOW
HIGH
[6]
tion greater than 9 dB (VDIF > 200 mV, or 400 mV peak-to-peak
differential) or can be directly connected to +5V fiber-optic interface
modules (any ECL logic family, not limited to ECL 100K). The common-mode tolerance of these line receivers accommodates a wide
range of signal termination voltages.
REFCLK[7]
Frequency
(MHz)
HIGH
LOW
100–200
10–20
HIGH
HIGH
100–200
20–40
As can be seen in Table 2, these inputs are configured to allow
single-pin control for most applications. For those systems requiring
selection of only INA± or INB±, the DLB signals can be tied LOW,
and the A/B selection can be performed using only A/B. For those
systems requiring only a single input and a local loopback, the A/B
can be tied HIGH or LOW, and DLB can be used for loopback control.
Notes:
6.When SPDSEL is LOW and the FIFOs are bypassed (FIFOBYP is LOW),
the RANGESEL input is ignored and is internally mapped to the LOW
setting.
7.When configured for 12-bit pre-encoded data (BYTE8/10 and ENCBYP are
both LOW) the allowable REFCLK ranges are 8.33 to 16.67 MHz and
16.67 to 33.33 MHz.
Signal Detect
The selected Line Receiver (that routed to the clock and data
recovery PLL) is simultaneously monitored for:
•analog amplitude (>400 mV pk-pk)
•transition density
•received data stream outside normal frequency range
(±400 ppm)
•and carrier detected.
All of these conditions must be valid for the Signal Detect block
to indicate a valid signal is present. This status is presented on
the LFI (Link Fault Indicator) output, which changes synchronous to RXCLK. While link status is monitored internally at all
times, it is necessary to have transitions on RXCLK to allow
this signal to change externally.
•the state of the transmitter BIST enable (TXBISTEN)
•the state of external halt signal (TXHALT)
These signals are used by the Transmit Control State Machine
to control the data formatter, read access to the Transmit FIFO
and BIST. They determine the content of the characters
passed to the Encoder and Transmit Shifter.
When the Transmit FIFO is bypassed, the Transmit Control
State Machine operates synchronous to REFCLK. In this
mode, data from the TXDATA bus is passed directly from the
Input Register to the Pipeline Register. If no data is enabled
into the Input register (TXEN is deasserted or TXFULL is asserted) then the Transmit Control State Machine presents a JK
or LM (when BYTE8/10 = LOW) Command Character code to
the Encoder to maintain link synchronization.
Clock/Data Recovery
The extraction of a bit-rate clock and recovery of data bits from
the received serial stream is performed within the Clock/Data
Recovery (CDR) block. The clock extraction function is performed by a high-performance embedded phase-locked loop
(PLL) that tracks the frequency of the incoming bit stream and
aligns the phase of its internal bit-rate clock to the transitions
in the serial data stream.
If both the Encoder and Transmit FIFO are bypassed and no
data is enabled into the Input Register, the Transmit Control
State Machine injects JK or LM (when BYTE8/10 = LOW) into
the Serial Shifter Register at this time slot. This also occurs if
the Encoder is bypassed, the Transmit FIFO is enabled, and
the Transmit FIFO is empty.
The CDR makes use of the clock present at the REFCLK input.
It is used to ensure that the VCO (within the CDR) is operating
at the correct frequency (rather than some harmonic of the bit
rate), to improve PLL acquisition time, and to limit unlocked
frequency excursions of the CDR VCO when no data is
present at the serial inputs.
External Control of Data Flow
The Transmit Control State Machine supports halting of data
transmission by the TXHALT input. This control signal input is
only interpreted when the Transmit FIFO is enabled. TXHALT
is brought directly to the state machine without going through
the Transmit FIFO.
Regardless of the type of signal present, the CDR will attempt
to recover a data stream from it. If the frequency of the recovered data stream is outside the limits for the range controls,
the CDR PLL will track REFCLK instead of the data stream.
When the frequency of the selected data stream returns to a
valid frequency, the CDR PLL is allowed to track the received
data stream. The frequency of REFCLK is required to be within
±400 ppm of the frequency of the clock that drives the REFCLK signal at the remote transmitter to ensure a lock to the
incoming data stream.
The assertion of TXHALT causes character processing to stop
at the next FIFO character location. No additional data is read
from the Transmit FIFO until TXHALT is deasserted
TXHALT may be used to prevent a remote FIFO overflow,
which would result in lost data. This back-pressure mechanism
can significantly improve data integrity in systems that cannot
guarantee the full bandwidth of the host system at all times
Serial Line Receivers
For systems using multiple or redundant connections, the LFI
output can be used to select an alternate data stream. When
an LFI indication is detected, external logic can toggle selection of the INA± and INB± inputs through the A/B input. When
a port switch takes place, it is necessary for the PLL to reacquire the new serial stream and frame to the incoming characters.
Two differential line receivers, INA± and INB±, are available for
accepting serial data streams, with the active input selected
using the A/B input. The DLB input allow the transmit Serializer
output to be selected as a third input serial stream, but this path
isgenerally used only for local diagnostic loopback purposes. The
serial line receiver inputs are all differential, and will accommodate
wire interconnect with filtering losses or transmission line attenua-
17
CY7C9689
Clock Divider
character sequence that includes all Data and Command
Character codes, including the explicit violation symbols. This
provides a predictable but pseudo-random sequence that can
be matched to an identical LFSR in the Transmitter. When synchronized with the received data stream, it checks each character in the Decoder with each character generated by the
LFSR and indicates compare errors at the VLTN output of the
Receive Output Register.
This block contains the clock division logic, used to transfer the
data from the Deserializer/Framer to the Decoder once every
character (once every ten or twelve bits) clock. This counter is
free running and generates outputs at the bit-rate divided by
10 (12 when the BYTE8/10 is LOW). When the Receive FIFO
is bypassed, one of these generated clocks is driven out the
RXCLK pin.
The LFSR is initialized by the BIST hardware to the BIST loop
start code of HEX data 00 (00 is sent only once per BIST loop).
Once the start of the BIST loop has been detected by the receiver, RXRVS is asserted for pattern mismatches between
the received characters and the internally generated character
sequence. Code rule violations or running disparity errors that
occur as part of the BIST loop do not cause an error indication.
RXFULL pulses asserted for one RXCLK cycle per BIST loop and
can be used to check test pattern progress.
Deserializer/Framer
The CDR circuit extracts bits from the serial data stream and
clocks these bits into the Shifter/Framer at the bit-clock rate.
When enabled, the Framer examines the data stream looking
for JK or LM (when BYTE8/10 is LOW) characters at all possible bit positions. The location of this character in the data
stream is used to determine the character boundaries of all
following characters.
The specific patterns checked by the receiver are described in
Table 4.
The framer operates in two different modes, as selected by the
RFEN input. When RFEN is asserted (HIGH), the framer is
allowed to reset the internal character boundaries on any detected JK or LM (when BYTE8/10 is LOW) character.
If a large number of errors are detected, the receive BIST state
machine aborts the compare operations and resets the LFSR
to the D0.0 state to look for the start of the BIST sequence
again.
If RFEN is LOW, the framer is disabled and no changes are
made to character boundaries.
The framer in the CY7C9689 operates by shifting the internal
character position to align with the character clock. This ensures that the recovered clock does not contain any significant
phase changes/hops during normal operation or framing, and
allows the recovered clock to be replicated and distributed to
other circuits using PLL-based logic elements.
Receive Control State Machine
The Receive Control State Machine responds to multiple input
conditions to control the routing and handling of received characters. It controls the staging of characters across various registers and the Receive FIFO. It controls the various discard
policies and error control within the receiver, and operates in
response to:
•the received character stream
•the room for additional data in the Receive FIFO
•the state of the receiver BIST enable (RXBISTEN)
•the state of FIFOBYP
These signals and conditions are used by the Receive Control
State Machine to control the Receive Formatter, write access
to the Receive FIFO, the Receive Output register, and BIST.
They determine the content of the characters passed to each
of these destinations,
Decoder Block
The decoder logic block performs two primary functions: decoding the received transmission characters back into Data
and Command Character codes, and comparing generated
BIST patterns with received characters to permit at-speed link
and device testing.
5B/4B, 6B/5B Decoder
The framed parallel output of the Deserializer is passed to the
5B/4B, 6B/5B Decoder. If the Decoder is enabled, it is transformed from a 10-bit or 12-bit transmission character back to
the original Data and Command Character codes. This block
uses the standard decoder patterns in Table 7 and Table 8 of
this data sheet. Data Patterns on the data bus are indicated by
a LOW on RXSC/D, and Command Character codes on the command bus are indicated by a HIGH. Invalid patterns or disparity errors are signaled as errors by a HIGH on VLTN.
The Receive Control State Machine always operates synchronous to the recovered character clock (bit-clock/10 or bitclock/12). When the Receive FIFO is bypassed, RXCLK becomes an output that changes synchronous to the internal
character clock. RXCLK operates at the same frequency as
the internal character clock.
If the Decoder is bypassed and BYTE8/10 is HIGH, the ten
(10) data bits of each transmission character are passed unchanged from the framer to the Pipeline Register.
Discard Policies
When the Receive FIFO is enabled, the Receive Control State
Machine has the ability to selectively discard specific characters from the data stream that are determined by the present
configuration as being unnecessary. When discarding is enabled, it reduces the host system overhead necessary to keep
the Receive FIFO from overflowing and losing data.
When the Decoder is bypassed and BYTE8/10 is LOW, the
twelve (12) data bits of each transmission character are
passed unchanged from the framer to the Pipeline Register.
BIST LFSR
The discard policy is configured as part of the operating mode
and is set using the RXMODE[1:0] inputs. The four discard
policies are listed in Table 5.
The output register of the Decoder block is normally used to
accumulate received characters for delivery to the Receive
Formatter block. When configured for BIST mode (RXBISTEN
is LOW), this register becomes a signature pattern generator
and checker by logically converting to a Linear Feedback Shift
Register (LFSR). When enabled, this LFSR generates a 511-
Policy 0 is the simplest and also applies for all conditions
where the Receive FIFO is bypassed. In this mode, every char-
18
CY7C9689
able 4. CY7C9689 TAXI HOTLink BIST Sequence
D.00
C.JK
C.TR
D.89
C.JK
C.IH
C.SR
D.42
C.IH
C.QI
C.SS
C.HI
C.SR
D.EE
C.QQ
D.94
C.SS
C.RR
D.F8
C.TT
C.QQ
D.B3
C.TS
C.TR
D.FB
D.55
C.QH
C.QI
D.77
D.2C
D.D2
D.EB
D.3D
C.JK
C.RR
D.73
D.1E
C.RS
D.BC
D.35
C.HH
D.C5
C.TT
D.1C
D.8F
D.68
C.QH
C.JK
D.4B
C.II
D.D7
C.RS
D.23
C.RS
D.6D
D.CF
D.11
D.C0
D.3A
D.6B
D.04
C.TS
C.HH
D.33
D.15
D.A8
D.99
D.D1
D.0C
C.TT
D.46
D.64
C.JK
C.QH
C.HI
C.II
C.RS
D.D4
D.96
C.IH
D.CD
C.TS
C.HQ
C.QI
D.6A
C.TR
D.AE
D.E4
C.HI
C.QI
C.HQ
C.RR
D.91
D.E3
D.A3
C.TR
D.44
D.71
D.51
C.QI
C.II
D.34
D.24
D.E0
C.IH
C.JK
C.JK
C.TS
C.QI
C.IH
C.IH
C.TR
D.E6
C.QI
C.QI
C.SR
C.RR
D.ED
D.EC
C.SS
D.B2
D.7A
C.TS
C.SS
C.HQ
C.HI
C.QH
C.SS
C.SS
C.QQ
D.50
D.DD
C.QQ
D.FC
C.II
D.6E
D.F0
C.TS
C.IH
C.HI
C.TS
C.QH
C.SR
D.93
C.TR
D.D3
C.QQ
D.45
C.SR
D.65
D.FD
D.28
C.QQ
D.38
D.7E
C.JK
D.F4
C.JK
C.HI
C.RS
C.TS
C.RS
D.9B
D.C4
C.TR
D.C6
D.47
C.TS
C.QI
C.RR
D.29
C.TR
D.E1
D.B6
D.12
C.QI
D.70
C.HQ
C.HH
D.E2
C.II
D.AA
D.8C
C.RR
C.IH
C.HQ
C.TT
D.B0
C.SR
D.A1
C.QH
C.TT
C.TR
D.17
D.BD
C.HI
C.SR
D.0D
D.5E
D.92
C.QQ
D.0A
C.HI
C.HQ
D.F6
C.HH
D.9F
D.AC
C.RR
D.85
D.4F
C.TT
D.BA
D.48
D.2B
C.QH
C.HQ
C.II
D.13
D.D5
D.A9
C.RS
D.05
D.6C
D.52
D.C8
D.08
C.II
C.HI
C.TS
C.JK
C.RS
D.9C
C.QH
C.RS
D.C1
C.TT
D.D8
D.CC
D.60
C.QH
C.TS
C.TS
C.II
D.DF
C.QH
C.QH
C.IH
D.6F
D.DA
D.D9
C.SR
D.3B
C.RR
D.66
C.SS
C.SS
C.TR
D.02
C.HH
C.SS
C.QI
C.HH
D.8A
C.QQ
D.E9
D.84
C.HQ
D.F1
D.72
C.TT
D.A5
D.74
C.HI
C.TR
D.58
C.II
D.98
C.QI
C.II
C.IH
C.TT
D.EA
C.RS
C.QI
C.QH
C.RR
D.CA
D.E5
D.DE
D.B1
C.RR
D.78
C.RR
D.54
D.B5
C.II
D.BF
C.II
D.5C
C.RS
D.5F
C.IH
C.II
D.C2
D.2F
C.QI
C.RS
C.RR
D.1B
D.E7
D.CB
D.B4
D.07
D.79
D.63
C.TT
D.09
D.36
D.31
D.14
C.TR
D.4D
C.HQ
C.JK
C.SR
D.2A
D.AF
C.IH
C.SS
C.HH
D.5B
C.QI
C.QQ
D.81
D.27
D.EF
D.F9
D.40
D.19
D.7B
D.76
C.II
D.06
D.37
C.HI
C.IH
C.HH
D.1D
D.9A
C.SR
D.86
D.0E
C.HQ
C.SS
C.HQ
C.HH
D.AD
C.QQ
D.A6
D.87
D.5A
D.FA
C.HQ
D.49
C.HI
C.RR
D.A2
D.22
D.9D
D.B9
C.HQ
C.HH
D.4E
D.56
D.AO
D.80
C.HI
C.HI
C.TT
C.TT
D.97
D.9E
C.TR
C.SR
D.18
C.SS
C.QH
C.SS
C.JK
C.QQ
D.DB
C.SS
C.RS
D.F3
D.67
C.QQ
D.CE
D.75
D.39
D.F2
C.RR
D.3C
D.16
C.RR
D.B7
C.JK
C.HH
D.B8
D.5D
C.RS
D.8E
C.TT
D.2E
D.C7
C.HQ
C.QH
C.HH
D.69
D.A7
D.D6
D.83
D.32
D.59
C.RR
D.41
C.HH
D.26
D.BE
D.20
D.88
C.HH
C.HQ
C.JK
C.TT
D.82
D.AB
C.IH
C.QH
C.HQ
D.53
C.SR
D.DC
D.A4
D.25
C.SS
C.TS
C.TT
C.TR
D.30
D.4C
D.43
C.QI
C.JK
C.II
D.21
D.E8
C.IH
C.RS
D.10
C.TS
C.SR
D.C9
C.JK
C.QH
C.QQ
D.62
C.IH
D.D0
D.FE
C.HI
C.SR
C.TS
C.RR
D.90
C.QQ
C.TR
D.BB
C.TT
D.FF
C.SR
D.57
C.TR
D.7F
C.QQ
D.2D
C.SR
D.3F
D.F5
D.1A
C.QQ
D.1F
D.7C
C.HH
D.F7
D.0F
C.II
D.8D
D.7D
D.0B
C.RS
D.4A
D.3E
D.03
D.C3
C.HI
C.HH
D.01
D.61
D.95
D.8B
GOTO
Start
Table 5. Receiver Discard Policies
Policy #
acter that is received is placed into the Receive FIFO (when
enabled) or into the Receive Output Register.
Policy Description
0 (00)
Keep all received characters
1 (01)
Process Commands, discard all but the last JK or
LM SYNC character
2 (1X)
Process Commands, discard all C5.0 characters
In discard policy 1, the JK or LM SYNC character, which is
automatically transmitted when no data is present in the Transmit FIFO, is treated differently here. In this mode, whenever
two or more adjacent JK or LM characters are received, all of
them are discarded except the last one received before any
other character type. This allows these fill characters to be
removed from the data stream, but the last SYNC character
which can be used as a delimiter.
19
CY7C9689
Policy 2 is identical to policy 1 except that all C5.0 characters
are removed from the data stream.
CY7C42x5 FIFO
When the FIFOs are bypassed (FIFOBYP LOW), no characters are actually discarded, but the receiver discard policy can
be used to control external filtering of the data. The RXEMPTY
FIFO flag is used to indicate if the character on the output bus
is valid or not. In discard policy 0, the RXEMPTY flag is always
deasserted to indicate that valid data is always present. In discard policy 1, the RXEMPTY flag indicates an empty condition
for all but the last JK or LM character before any other character is presented. In discard policy 2, the RXEMPTY flag indicates an empty condition for all JK or LM SYNC characters.
When any other character is present, this flag indicates that
valid or “interesting” Data or Special Characters are present.
EF*
REN*
D
RXCLK
RXEMPTY
WEN*
Q
D
RCLK
RXEN
FF*
EF*
REN*
CY7C9689
RXDATA
RXSC/D
WCLK
RXCLK
“1”
Receive FIFO
The Receive FIFO is used to buffer data captured from the
selected serial stream for later processing by the host system.
This FIFO is sized to hold 256 14-bit characters. When the
FIFO is enabled, it is written to by the Receive Control State
Machine. When data is present in the Receive FIFO (as indicated by the RXFULL, RXHALF, and RXEMPTY Receive FIFO
status flags), it can be read from the Output Register by asserting CE and RXEN.
EXTFIFO
Figure 4. External FIFO Depth Expansion of the CY7C9689
Receive Data Path
Receive Output Register
The Receive Output Register changes in response to the rising edge of RXCLK. The Receive FIFO status flag outputs of
this register are placed in a High-Z state when the CY7C9689
is not addressed (CE is sampled HIGH). The RXDATA bus
output drivers are enabled when the device is selected by
RXEN being asserted in the RXCLK cycle immediately following that in which the device was addressed (CE is sampled
LOW), and RXEN being sampled by RXCLK. This initiates a
Receive FIFO read cycle.
The read port on the Receive FIFO may be configured for the
same two timing models as the transmit interface: UTOPIA and
Cascade. Both are forms of a FIFO interface. The UTOPIA
timing model has active LOW RXEMPTY and RXFULL status
flags, and an active LOW RXEN enable. When configured for
Cascade operation, these same signals are all active HIGH.
Either timing model supports connection to various host bus
interfaces, state machines, or external FIFOs for depth expansion (see Figure 4).
Just as with the TXDATA bus on the Transmit Input Register,
the receive outputs are also mapped by the specific decoding,
parity, and bus-width selected by the ENCBYP, BYTE8/10 and
FIFOBYP inputs. These assignments are shown in Table 6.
The Receive FIFO presents Full, Half-Full, and Empty FIFO
status flags. These flags are provided synchronous to RXCLK
to allow operation with a Moore-type external controlling state
machine. When configured with the Receive FIFO enabled,
RXCLK is an input. When the Receive FIFO is bypassed
(FIFOBYP is LOW), RXCLK is an output operating at the received character rate.
If the Receive FIFO and Decoder are bypassed, all received
characters are passed directly to the Receive Output Register.
If framing is enabled, and JK or LM sync characters have been
detected meeting the present framing requirements, the output characters will appear on proper character boundaries. If
framing is disabled (RFEN is LOW) or sync characters have
not been detected in the data stream, the received characters
may not be output on their proper 10-bit boundaries. In this
mode, some form of external framing and decoding/descrambling must be used to recover the original source data.
Receive Input Register
The input register is clocked by the rising edge of RXCLK. It
samples numerous signals that control the reading of the Receive FIFO and operation of the Receive Control State Machine.
20
CY7C9689
Table 6. Receiver Output Bus Signal Map
Receiver Decoder Mode[1]
RXDATA Bus Output Bit
Encoded 8-bit
Character Stream[8]
RXSC/D
RXSC/D
Pre-encoded 10-bit
Character Stream
Encoded 10-bit
Character Stream[9]
Pre-encoded 12-bit
Character Stream
RXSC/D
RXDATA[0]
RXD[0][10, 12]
RXD[1]
RXDATA[1]
RXD[1]
RXD[2]
RXDATA[2]
RXD[2]
RXDATA[3]
RXD[3]
RXDATA[3]
RXD[3]
RXDATA[4]
RXDATA[4]
RXD[4]
RXDATA[4]
RXD[4]
RXDATA[5]
RXDATA[5]
RXD[5]
RXDATA[5]
RXD[5]
RXDATA[6]
RXDATA[6]
RXD[6]
RXDATA[6]
RXD[6]
RXDATA[7]
RXDATA[7]
RXD[7]
RXDATA[7]
RXD[7]
RXDATA[8]/RXCMD[3]
RXCMD[3]
RXD[8]
RXDATA[8]
RXD[8]
RXDATA[0]
RXDATA[0]
RXDATA[1]
RXDATA[1]
RXDATA[2]
RXDATA[2]
RXDATA[3]
[10, 11]
RXD[0]
[9]
RXD[9]
RXDATA[9]
RXD[9]
RXDATA[9]/RXCMD[2]
RXCMD[2]
RXCMD[1]
RXCMD[1]
RXCMD[1]
RXD[10][12]
RXCMD[0]
RXCMD[0]
RXCMD[0]
RXD[11]
VLTN
VLTN
VLTN
Maximum Ratings
Static Discharge Voltage .......................................... > 2001V
(per MIL-STD-883, Method 3015)
(Above which the useful life may be impaired. For user guidelines, not tested.)
Latch-Up Current .................................................... > 200 mA
Storage Temperature ................................–65×C to +150×C
Operating Range
Ambient Temperature with (Power Applied)–55×C to +125×C
Supply Voltage to Ground Potential ............... –0.5V to +6.5V
Range
DC Voltage Applied to Outputs ................–0.5V to VDD+0.5V
Output Current into TTL Outputs (LOW)...................... 30 mA
Commercial
Industrial
Ambient
Temperature
VDD
0°C to +70°C
5.0V ± 10%
–40°C to +85°C
5.0V ± 10%
DC Input Voltage......................................–0.5V to VDD+0.5V
Notes:
8. When BYTE8/10 is HIGH, received bit order is decoded form the serial stream and presented (MSB to LSB) at RXDATA[7,6,5,4] and RXDATA[3,2,1,0] or
RXCMD[3,2,1,0] as indicated by RXSC/D.
9. When BYTE8/10 is LOW, received bit order is decoded form the serial stream and presented (MSB to LSB) at RXDATA[8,7,6,5,4] and RXDATA[9,3,2,1,0] or
RXCMD[1,0] as indicated by RXSC/D
10. First bit shifted into the receiver.
11. When ENCBYP is LOW and BYTE8/10 is HIGH, the received bit order is (LSB to MSB) RXD[0,1,2,3,4,5,6,7,8,9].
12. When ENCBYP is LOW and BYTE8/10 is LOW, the received bit order is (LSB to MSB) RXD[0,1,2,3,4,5,6,7,8,9,11,10].
21
CY7C9689
CY7C9689 DC Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
Min.
Max.
Unit
TTL Outputs
VOHT
Output HIGH Voltage
IOH = −2 mA, VDD = Min.
VOLT
Output LOW Voltage
IOL = 8 mA, VDD = Min.
IOST
Output Short Circuit Current
IOZL
High-Z Output Leakage Current
VOUT = 0V
[13]
2.4
V
0.4
V
–30
−80
mA
–20
20
mA
TTL Inputs
VIHT
Input HIGH Voltage
2.0
VCC
V
VILT
Input LOW Voltage
–0.5
0.8
V
µA
IIHT
Input HIGH Current
VIN = VDD
±40
IILT
Input LOW Current
VIN = 0.0V
−40
µA
IILPDT
Input HIGH Current with Internal
Pull-Down
VIN = VCC
+300
µA
IILPUT
Input LOW Current with Internal
Pull-Up
VIN = 0.0V
µA
–300
Transmitter PECL-Compatible Output Pins: OUTA+, OUTA−, OUTB+, OUTB−
VOHE
Output HIGH Voltage
(VDD referenced)
Load = 50Ω to VDD − 1.33V
RCURSET= 10k
VDD − 1.03
VDD − 0.83
V
VOLE
Output LOW Voltage
(VDD referenced)
Load = 50Ω to VDD − 1.33V
RCURSET=10k
VDD − 2.0
VDD − 1.62
V
VODIF
Output Differential Voltage
|(OUT+) − (OUT−)|
Load = 50Ω to VDD − 1.33V
RCURSET=10k
600
1100
mV
Receiver Single-ended PECL-Compatible Input Pin: CARDET
VIHE
Input HIGH Voltage
(VDD referenced)
VDD−1.165
VDD
V
VILE
Input LOW Voltage
(VDD referenced)
2.5
VDD−1.475
V
+40
µA
IIHE
Input HIGH Current
IILE
Input LOW Current
–40
VDIFF
Input Differential Voltage
|(IN+) − (IN−)|
200
VIHH
Highest Input HIGH Voltage
VILL
Lowest Input LOW Voltage
IIHH
Input HIGH Current
VIN = VIHH Max.
IILL[14]
Input LOW Current
VIN = VILL Min.
VIN = VIHE(min.)
VIN = VILE(max.)
Receiver Differential Line Receiver Input Pins: INA+, INA−, INB+, INB−
Power Supply Current
2500
mV
VDD
V
2.5
Freq. = Max.
V
µA
750
−200
Miscellaneous
IDD[15]
µA
Commercial
µA
Typ.
Max.
170
250
mA
Capacitance[16]
Parameter
Description
Test Conditions
Max.
Unit
CINTTL
TTL Input Capacitance
TA = 25°C, f0 = 1 MHz, VDD = 5.0V
7
pF
CINPECL
PECL input Capacitance
TA = 25°C, f0 = 1 MHz, VDD = 5.0V
4
pF
Notes:
13. Tested one output at a time, output shorted for less than one second, less than 10% duty cycle.
14. To guarantee positive currents for all PECL voltages, an external pull-down resistor must be present.
15. Maximum ICC is measured with VDD = MAX, RFEN = LOW, and outputs unloaded. Typical IDD is measured with VDD = 5.0V, TA = 25°C, RFEN = LOW, and
outputs unloaded.
16. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
22
CY7C9689
AC Test Loads and Waveforms
5.0V
R1
OUTPUT
R1=500 Ω
R2=333 Ω
CL ≤ 10 pF
(Includes fixture and
probe capacitance)
VDD – 1.3
CL
CL
R2
(a) TTLAC Test Load
Vth=1.5V
0.0V
[17]
(b) PECL AC Test Load
3.0V
3.0V
RL
2.0V
2.0V
80%
Vth=1.5V
0.8V
VILE
< 1 ns
[17]
VIHE
VIHE
0.8V
80%
20%
20%
VILE
≤ 250 ps
< 1 ns
RL =50 Ω
C L < 5 pF
(Includes fixture and
probe capacitance)
(c) TTL Input Test Waveform
≤ 250 ps
(d) PECL Input Test Waveform
CY7C9689 Transmitter TTL Switching Characteristics, FIFO Enabled Over the Operating Range
Parameter
Description
Min.
Max.
Unit
50
MHz
fTS
TXCLK Clock Cycle Frequency With Transmit FIFO Enabled
tTXCLK
TXCLK Period
20
ns
tTXCPWH
TXCLK HIGH Time
6.5
ns
tTXCPWL
TXCLK LOW Time
6.5
ns
[18]
tTXCLKR[16]
tTXCLKF[16]
TXCLK Rise Time
tTXA
Flag Access Time From TXCLK↑ to Output
tTXDS
Transmit Data Set-Up Time to TXCLK↑
4
ns
tTXDH
Transmit Data Hold Time from TXCLK↑
1
ns
0.7
[18]
TXCLK Fall Time
5
ns
0.7
5
ns
2
15
ns
tTXENS
Transmit Enable Set-Up Time to TXCLK↑
4
ns
tTXENH
Transmit Enable Hold Time from TXCLK↑
1
ns
tTXRSS
Transmit FIFO Reset (TXRST) Set-Up Time to TXCLK↑
4
ns
tTXRSH
Transmit FIFO Reset (TXRST Hold Time from TXCLK↑
1
ns
tTXCES
Transmit Chip Enable (CE) Set-Up Time to TXCLK↑
4
ns
tTXCEH
Transmit Chip Enable (CE) Hold Time from TXCLK↑
1
ns
tTXZA
Sample of CE LOW by TXCLK↑, Output High-Z to Active HIGH or LOW
0
ns
tTXOE
Sample of CE LOW by TXCLK↑ to Output Valid
1.5
20
ns
tTXAZ
Sample of CE HIGH by TXCLK↑ to Output in High-Z
1.5
20
ns
Notes:
17. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.
18. Input/output rise and fall time is measured between 0.8V and 2.0V
23
CY7C9689
CY7C9689 Receiver TTL Switching Characteristics, FIFO Enabled Over the Operating Range
Parameter
Description
Min.
Max.
Unit
50
MHz
fRIS
RXCLK Clock Cycle Frequency With Receive FIFO Enabled
tRXCLKIP
RXCLK Input Period
20
ns
tRXCPWH
RXCLK Input HIGH Time
6.5
ns
tRXCPWL
RXCLK Input LOW Time
6.5
ns
[18]
tRXCLKIR[16]
tRXCLKIF[16]
RXCLK Input Rise Time
tRXENS
Receive Enable Set-Up Time to RXCLK↑
4
ns
tRXENH
Receive Enable Hold Time from RXCLK↑
1
ns
tRXRSS
Receive FIFO Reset (RXRXT) Set-Up Time to RXCLK↑
4
ns
tRXRSH
Receive FIFO Reset (RXRXT) Hold Time from RXCLK↑
1
ns
tRXCES
Receive Chip Enable (CE) Set-Up Time to RXCLK↑
4
ns
tRXCEH
Receive Chip Enable (CE) Hold Time from RXCLK↑
1
ns
tRXA
Flag and Data Access Time From RXCLK↑ to Output
[18]
RXCLK Input Fall Time
0.7
5
ns
0.7
5
ns
1.5
[19]
15
ns
tRXZA
Sample of CE LOW by RXCLK↑, Output High-Z to Active HIGH or LOW,
or Sample of RXEN Asserted by RXCLK↑, Output High-Z to Active HIGH
or LOW
tRXOE
Sample of CE LOW by RXCLK↑ to Output Valid,[19]
or Sample of RXEN Asserted by RXCLK↑ to RXDATA Outputs Valid
1.5
20
ns
tRXZA
Sample of CE HIGH by RXCLK↑ to Output in High-Z,[19]
or Sample of RXEN Asserted by RXCLK↑ to RXDATA Outputs in High-Z
1.5
20
ns
0
ns
CY7C9689 Transmitter TTL Switching Characteristics, FIFO Bypassed Over the Operating Range
Parameter
Description
Min.
Max.
Unit
15
ns
tTRA
Flag Access Time From REFCLK↑ to Output
2
tREFDS
Write Data Set-Up Time to REFCLK↑
4
ns
tREFDH
Write Data Hold Time from REFCLK↑
2
ns
tREFENS
Transmit Enable Set-Up Time to REFCLK↑
4
ns
tREFENH
Transmit Enable Hold Time from REFCLK↑
2
ns
tREFCES
Transmit Chip Enable (CE) Set-Up Time to REFCLK↑
4
ns
tREFCEH
Transmit Chip Enable (CE) Hold Time from REFCLK↑
2
ns
tREFZA
Sample of CE LOW by REFCLK↑, Output High-Z to Active HIGH or LOW
0
ns
tREFOE
Sample of CE LOW by REFCLK↑ to Flag Output Valid
1.5
20
ns
tREFAZ
Sample of CE HIGH by REFCLK↑ to Flag Output High-Z
1.5
20
ns
Note:
19. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
24
CY7C9689
CY7C9689 Receiver TTL Switching Characteristics, FIFO Bypassed Over the Operating Range
Parameter
fROS[20]
Description
Min.
Max.
Unit
RXCLK Clock Output Frequency—100 to 200 MBaud 8-bit Operation
(SPDSEL is HIGH and BYTE8/10 is HIGH)
10
20
MHz
RXCLK Clock Output Frequency—50 to 100 MBaud 8-bit Operation
(SPDSEL is LOW and BYTE8/10 is HIGH)
5
10
MHz
RXCLK Clock Output Frequency—100 to 200 MBaud 10-bit Operation
(SPDSEL is HIGH and BYTE8/10 is LOW)
8.33
16.67
MHz
RXCLK Clock Output Frequency—50 to 100 MBaud 10-bit Operation
(SPDSEL is LOW and BYTE8/10 is LOW)
4.16
8.33
MHz
25
240
ns
40
60
%
tRXCLKOP
RXCLK Output Period
tRXCLKOD
RXCLK Output Duty Cycle
tRXCLKOR[16]
tRXCLKOF[16]
[18]
RXCLK Output Rise Time
0.25
2
ns
RXCLK Output Fall Time[18]
0.25
2
ns
tRXENS
Receive Enable Set-Up Time to RXCLK↑
4
ns
tRXENH
Receive Enable Hold Time from RXCLK↑
1
ns
tRXZA
Sample of CE LOW by RXCLK↑, Outputs High-Z to Active
Sample of RXEN Asserted by RXCLK↑ to RXDATA Outputs High-Z to Active
0
ns
tRXOE
Sample of CE LOW by RXCLK↑ to Flag Output Valid
Sample of RXEN Asserted by RXCLK↑ to RXDATA Output Low-Z
1.5
20
ns
tRXAZ
Sample of CE HIGH by RXCLK↑ to Flag Output High-Z
Sample of RXEN Deasserted by RXCLK↑ to RXDATA Output High-Z
1.5
20
ns
CY7C9689 REFCLK Input Switching Characteristics Over the Operating Range
Conditions
Parameter
fREF
Description
SPDSEL
RANGESEL BYTE8/10
Min.
Max.
Unit
REFCLK Clock Frequency—50 to 100 MBaud,
10-bit Mode, REFCLK = 2x Character Rate
0
0
0
8.33
16.67
MHz
REFCLK Clock Frequency—50 to 100 MBaud,
8-bit Mode, REFCLK = 2x Character Rate
0
0
1
10
20
MHz
REFCLK Clock Frequency—50 to 100 MBaud,
10-bit Mode, REFCLK = 4x Character Rate
0
1[21]
0
16.67
33.3
MHz
REFCLK Clock Frequency—50 to 100 MBaud,
8-bit Mode, REFCLK = 4x Character Rate
0
1[21]
1
20
40
MHz
REFCLK Clock Frequency—100 to 200 MBaud,
10-bit Mode, REFCLK = Character Rate
1
0
0
8.33
16.67
MHz
REFCLK Clock Frequency—100 to 200 MBaud,
8-bit Mode, REFCLK = Character Rate
1
0
1
10
20
MHz
REFCLK Clock Frequency—100 to 200 MBaud,
10-bit Mode, REFCLK = 2x Character Rate
1
1
0
16.67
33.3
MHz
REFCLK Clock Frequency—100 to 200 MBaud,
8-bit Mode, REFCLK = 2x Character Rate
1
1
1
20
40
MHz
25
120
ns
tREFCLK
REFCLK Period
tREFH
REFCLK HIGH Time
6.5
ns
tREFL
REFCLK LOW Time
6.5
ns
tREFRX
REFCLK Frequency Referenced to Received Clock Period
[22]
−0.04
+0.04
%
Notes:
20. The period of tROS will match the period of the transmitter PLL reference (REFCLK) when receiving serial data. When data is interrupted, RXCLK may drift to REFCLK +0.2%.
21. When configured for synchronous operation with the FIFOs bypassed (FIFOBYP is LOW), if RANGESEL is HIGH the SPDSEL input is ignored and operation
is forced to the 100–200 MBaud range.
22. REFCLK has no phase or frequency relationship with RXCLK and only acts as a centering reference to reduce clock synchronization time. REFCLK must be
within ±0.04% of the transmitter PLL reference (REFCLK) frequency, necessitating a ±200-PPM crystal.
25
CY7C9689
CY7C9689 Receiver Switching Characteristics Over the Operating Range
Parameter
tB[23]
tSA
tEFW
tIN_J
Description
Bit Time
Min.
Max.
Unit
20.0
5.0
ns
600
ps
[16, 24]
Static Alignment
[16, 25, 26]
Error Free Window
0.65
[16, 25, 27, 30]
IN± Peak-to-Peak Input Jitter Tolerance
UI
0.5
UI
Min.
Max.
Unit
20.0
5.0
ns
200
1700
ps
200
1700
ps
0.02
UI
0.008
UI
0.08
UI
CY7C9689 Transmitter Switching Characteristics Over the Operating Range
Parameter
tB[23]
tRISE
tFALL
tDJ
tRJ
tJT
Description
Bit Time
PECL Output Rise Time 20−80% (PECL Test Load)
PECL Output Fall Time 80−20% (PECL Test Load)
[16, 28]
Deterministic Jitter (peak-peak)
Random Jitter (σ)
[16, 29]
[16]
Transmitter Total Output Jitter (peak-peak)
[16]
[16]
Notes:
23. The PECL switching threshold is the midpoint between the PECL− VOH, and VOL specification (approximately VDD − 1.33V).
24. Static alignment is a measure of the alignment of the Receiver sampling point to the center of a bit. Static alignment is measured by the absolute difference
of the left and right edge shifts (|t SH_L – tSH_R|) of one bit until a character error occurs.
25. Receiver UI (Unit Interval) is calculated as 1/(fREF *N) when operated in 8-bit mode (N=10) and 10-bit mode (N=12) if no data is being received, or 1/(fREF *N)
of the remote transmitter if data is being received. In an operating link this is equivalent to N * tB when REFCLK = 1X the character rate. An alternate multiply
ratios (2X or 4X, as selected by SPDSEL and RANGESEL), the numerator is multiplied by 2 or 4 respectively.
26. Error Free Window is a measure of the time window between bit centers where a transition may occur without causing a bit sampling error. EFW is measured
over the operating range, input jitter < 50% Dj.
27. The specification is sum of 25% Duty Cycle Distortion (DCD), 10% Data Dependant Jitter (DDJ), 15% Random Jitter (RJ).
28. While sending continuous JK, outputs loaded to 50Ω to VDD−1.3V, over the operating range.
29. While sending continuous HH, after 100,000 samples measured at the cross point of differential outputs, time referenced to REFCLK input, over the operating
range
30. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
26
CY7C9689
CY7C9689 HOTLink Transmitter Switching Waveforms
Write Cycle
Asynchronous (FIFO) Interface
EXTFIFO=HIGH
FIFOBYP=HIGH
tTXCLK
tTXCPWH
tT X CP W L
TXCLK
t TX D S
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
tT X D H
Note 31
tT X E N H
NO OPERATION
TXEN
t TX E N S
tTXA
TXFULL
TXHALF
TXEMPTY
tTXA
Write Cycle
Asynchronous (FIFO) Interface
EXTFIFO=LOW
FIFOBYP=HIGH
TXCLK
tT X D S
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
tT X D H
Note 32
tT X E N S
tT X E N H
TXEN
NO OPERATION
tTXA
TXFULL
TXHALF
TXEMPTY
tT X A
Notes:
31. When EXTFIFO is HIGH, the write data is captured on the clock cycle following TXEN = HIGH.
32. When EXTFIFO is LOW, the write data is captured on the same clock cycle as the TXEN=LOW.
27
CY7C9689
CY7C9689 HOTLink Transmitter Switching Waveforms (continued)
OUTPUT ENABLE Timing
Asynchronous (FIFO) Interface
EXTFIFO=HIGH
FIFOBYP=HIGH
TXCLK
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
NO OPERATION
TXEN
Note 33
tT X RS S
tT X R S H
TXRST
tT X CE S
tT X C E H
CE
tT X O E
tT X O A Z
TXFULL
TXHALF
TXEMPTY
t TX O Z A
OUTPUT ENABLE Timing
Asynchronous (FIFO) Interface
EXTFIFO=LOW
FIFOBYP=HIGH
TXCLK
TXHALT
TXSC/D
TXDATA[7:0]
XDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
TXEN
NO OPERATION
tT X R S S
CE
TXRST
tT X R S H
Note 33
tT X C E S
tT X C E H
CE
TXRST
tT X O E
TXFULL
TXHALF
TXEMPTY
t TX O Z A
Note:
33. Illustrates timing only. TXEN and TXRST not usually active in same time period.
28
tT X O A Z
CY7C9689
CY7C9689 HOTLink Transmitter Switching Waveforms (continued)
Write Cycle
Synchronous Interface
EXTFIFO=HIGH
tREFCLK
tREFH
tR E FL
FIFOBYP=LOW
REFCLK
tR E F D S
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
tR E F D H
Note 34
t R E F EN H
NO OPERATION
TXEN
tR E F E N S
t
TRA
TXFULL
TXHALF
TXEMPTY
t
TRA
Write Cycle
Synchronous Interface
EXTFIFO=LOW
FIFOBYP=LOW
REFCLK
tR E FD S
TXHALT
TXSC/D
TXDATA[7:0]
DATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
tR E F D H
Note 35
tR E F E N S
TXEN
tR E FE N H
NO OPERATION
TXFULL
TXHALF
TXEMPTY
Notes:
34. When transferring data to the Transmitter input from a depth expanded external FIFO, the data is captured from the external FIFO one clock cycle following
the actual enable (TXEN = HIGH).
35. When transferring data to the Transmitter input from a synchronous external controller, the data is captured in the same clock cycle as the actual enable
(TXEN = LOW).
29
CY7C9689
CY7C9689 HOTLink Transmitter Switching Waveforms (continued)
OUTPUT ENABLE Timing
Synchronous Interface
EXTFIFO=HIGH
FIFOBYP=LOW
REFCLK
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
t R EF E N H
NO OPERATION
TXEN
tR E F E N S
tR E F C E S
tR E FC E H
CE
tR E F O E
tR E F A Z
TXFULL
TXEMPTY
tR E F Z A
OUTPUT ENABLE Timing
Synchronous Interface
EXTFIFO=LOW
FIFOBYP=LOW
REFCLK
TXHALT
TXSC/D
TXDATA[7:0]
TXDATA[9:8]/TXCMD[2:3]
TXCMD[1:0]
TXEN
NO OPERATION
CE
TXFULL
TXEMPTY
30
CY7C9689
CY7C9689 HOTLink Receiver Switching Waveforms
Read Cycle
Asynchronous (FIFO) Interface
EXTFIFO=HIGH
tRXCLKOP
tRXCLKIP
FIFOBYP=HIGH
tRXCLKOD
tRXCPWH
tRXCLKOD
tRXCPWL
RXCLK
tRXENH
tRXENS
RXEN
NO OPERATION
READ
READ
tRXA
tRXA
Note 36
RXEMPTY
FIFO EMPTY
LFI
RXFULL
RXHALF
RXDATA[7:0]
RXDATA[9:8/RXCMD[2:3]
RXCMD[1:0]
VALID DATA
Note 37
CE
Read Cycle
Asynchronous (FIFO) Interface
EXTFIFO=LOW
FIFOBYP=HIGH
RXCLK
tRXENS
RXEN
tRXENH
READ
tRXA
tRXA
FIFO EMPTY
RXEMPTY
LFI
RXFULL
RXHALF
RXDATA[7:0]
RXDATA[9:8/RXCMD[2:3]
RXCMD[1:0]
VALID DATA
Note 38
CE
Notes:
36. When transferring data from the Receive FIFO to a depth expanded external FIFO, the data is sent to the external FIFO on the same clock cycle that
RXEN=HIGH. RXEMPTY=LOW indicates that data is available.
37. On inhibited reads, or if the Receive FIFO goes empty, the data outputs do not change.
38. When reading data from synchronous data interface, the data is captured on any clock cycle that RXEN=LOW. RXEMPTY=HIGH indicates data is available.
RXEMPTY=LOW indicates that the FIFO is empty.
31
CY7C9689
CY7C9689 HOTLink Receiver Switching Waveforms (continued)
Output Enable Timing
RXCLK
tR X E N H
tR X E N S
RXEN
NO OPERATION
Note 39
tR X R S H
tR X R S S
RXRST
tR X C E S
tR X C E H
CE
tR X A Z
tR X O E
LFI
RXFULL
RXDATA[7:0]
RXDATA[9:8/RXCMD[2:3]
RXCMD[1:0]
OLD DATA
Note 40
tR X Z A
tREFCLK
tREFL
tREFH
REFCLK
Static Alignment
Error-Free Window
tB/2− tSA
tB/2− tSA
tEFW
INA±
INB±
INA±
INB±
tB
BIT CENTER
SAMPLE WINDOW
Notes:
39. Illustrates timing only. RXEN and RXRST not usually active in same time period.
40. Receive FIFO Reads are inhibited while the outputs are High-Z.
32
BIT CENTER
CY7C9689
Table 7. HOTLink TAXI Compatible Encoder Patterns
4B/5B Encoder
5B/6B Encoder
HEX
Data
4-bit Binary
Data[41]
5-bit Encoded
Symbol[42, 43]
HEX
Data
5-bit Binary
Data[41]
6-bit Encoded
Symbol[42, 43]
0
0000
11110
00
00000
110110
1
0001
01001
01
00001
010001
2
0010
10100
02
00010
100100
3
0011
10101
03
00011
100101
4
0100
01010
04
00100
010010
5
0101
01011
05
00101
010011
6
0110
01110
06
00110
010110
7
0111
01111
07
00111
010111
8
1000
10010
08
01000
100010
9
1001
10011
09
01001
110001
A
1010
10110
0A
01010
110111
B
1011
10111
0B
01011
100111
C
1100
11010
0C
01100
110010
D
1101
11011
0D
01101
110011
E
1110
11100
0E
01110
110100
F
1111
11101
0F
01111
110101
10
10000
111110
11
10001
011001
12
10010
101001
13
10011
101101
14
10100
011010
15
10101
011011
16
10110
011110
17
10111
011111
18
10001
101010
19
11001
101011
1A
11010
101110
1B
11011
101111
1C
11100
111010
1D
11101
111011
1E
11110
111100
1F
11111
111101
Notes:
41. Binary Input Data is the parallel input data which is input to the Transmitter and output from the Receiver. Binary bits are listed from left to right in the following
order:
8-Bit mode (BYTE8/10 is HIGH and TXSC/D or RXSC/D is LOW)—TXDATA/RXDATA[7], [6], [5], [4], and TXDATA/RXDATA[3], [2], [1], [0].
10-Bit mode (BYTE8/10 is LOW and TXSC/D or RXSC/D is LOW)—TXDATA/RXDATA[8], [7], [6], [5], [4], and TXDATA/RXDATA[9], [3], [2], [1], [0].
42. The ENCODED Symbols are shown here as “ones and zeros”, but are converted to and from an NRZI stream at the transmitter output and receiver input.
NRZI represents a “one” as a state transition (either LOW-to-HIGH or HIGH-to-LOW) and a “zero” as no transition within the bit interval.
43. Encoded Serial Symbol bits are shifted out with the most significant bit (Left-most) of the most significant nibble coming out first.
33
CY7C9689
Table 8. HOTLink TAXI Compatible Command Symbols
CY7C9689 (Transmitter)
CY7C9689 (Receiver)
Command Input
TXCMD[3:0]
Command Output
RXCMD[3:0]
HEX
Binary CMD[44]
Encoded
Symbol[42, 43]
Mnemonic
HEX
Binary CMD[44]
8-bit mode (BYTE8/10 is HIGH)
0
0000
11000 10001
JK (8-bit SYNC)
0
0000
1
0001
11111 11111
II
1
0001
2
0010
01101 01101
TT
2
0010
3
0011
01101 11001
TS
3
0011
4
0100
11111 00100
IH
4
0100
5
0101
01101 00111
TR
5
0101
6
0110
11001 00111
SR
6
0110
7
0111
11001 11001
SS
7
0111
8
[45]
1000
00100 00100
HH
8
1000
9
[45]
1001
00100 11111
HI
9
1001
[45]
1010
00100 00000
HQ
A
1010
B
1011
00111 00111
RR
B
1011
C
1100
00111 11001
RS
C
1100
[45]
1101
00000 00100
QH
D
1101
[45]
1110
00000 11111
QI
E
1110
[45]
1111
00000 00000
QQ
F
1111
A
D
E
F
10-bit mode (BYTE8/10 is LOW)
0
00
011000 100011
LM (10-bit SYNC)
0
00
1
01
111111 111111
I’I’
1
01
2
10
011101 011101
T’T’
2
10
3
11
011101 111001
T’S’
3
11
Notes:
44. Binary CMD is the parallel input data which is input to the Transmitter and output from the Receiver. Binary bits are listed from left to right in the following order:
8-Bit mode (BYTE8/10 is HIGH and TXSC/D or RXSC/D is HIGH)—TXCMD/RXCMD[3], [2], [1], [0].
10-Bit mode (BYTE8/10 is LOW and TXSC/D or RXSC/D is HIGH)—TXCMD/RXCMD[1], [0].
45. While these Commands are legal data and will not disrupt normal operation if used occasionally, they may cause data errors if grouped into recurrent fields.
Normal PLL operation cannot be guaranteed if one or more of these commands is continuously repeated.
34
CY7C9689
Synchronous Encoded
Functional Description
In this mode, the Transmit FIFO is bypassed, while the 4B/5B,
5B/6B encoder is enabled. One character is accepted at the
Transmit Input Register at the rising edge of REFCLK, and
passed to the Encoder where it is encoded for serial transmission. The Serializer operates synchronous to REFCLK, which
is multiplied by 10 or 5 to generate the serial data bit-clock. In
this mode the TXRST and TXHALT inputs are not interpreted
and may be tied either HIGH or LOW. To place the CY7C9689
into synchronous modes, FIFOBYP must be LOW.
The interconnection of two or more CY7C9689 Transceivers
forms a general-purpose communications subsystem capable
of transporting user data at up to 20 MBytes per second over
several types of serial interface media. The CY7C9689 is highly configurable with multiple modes of operation.
In the transmit section of the CY7C9689, data moves from the
input register, through the Transmit FIFO, to the 4B/5B Encoder. The encoded data is then shifted serially out the OUTx±
differential PECL compatible drivers. The bit-rate clock is generated internally from a 2.5x, 5x, or 10x PLL clock multiplier. A
more complete description is found in the section CY7C9689
HOTLink Transmit-Path Operating Mode Description.
This mode is usually used for products that must meet specific
predefined protocol requirements, and cannot tolerate the uncontrolled insertion of SYNC fill characters. The host system
is required to provide new data at every rising edge of REFCLK
(along with TXEN) to maintain the data stream. If TXEN is not
asserted, the Encoder is loaded with JK or LM sync characters.
In the receive section of the CY7C9689, serial data is sampled
by the receiver on one of the INx± differential line receiver inputs. The receiver clock and data recovery PLL locks onto the
selected serial bit stream and generates an internal bit-rate
sample clock. The bit stream is deserialized, decoded, and
presented to the Receive FIFO, along with a character clock.
The data in the FIFO can then be read either slower or faster
than the incoming character rate. A more complete description
is found in the section CY7C9689 HOTLink Receive-Path Operating Mode Description.
Input Register Mapping
In Encoded modes, the bits of the TXDATA input bus are
mapped into characters (as shown in Table 1), including a
TXSVS bit, eight bits of data, and a TXSC/D bit to select either
Special Character codes or Data characters.
The TXSC/D bit controls the encoding of the TXDATA[7:0] or
TXDATA[9:0] bits of each character. It is used to identify if the
input character represents a Data Character or a Special
Character code. If TXSC/D is LOW, the character appeared on
the TXDATA bus is encoded using the Data Character codes
listed in Table 7. If TXSC/D is HIGH, the character on the TXCMD bus is encoded using the Special Character codes listed
in Table 8.
The Transmitter and Receiver parallel interface timing and
functionality can be configured to Cascade directly to external
FIFOs for depth expansion, couple directly to registers, or couple directly to state machines. These interfaces can accept or
output either:
•8-bit characters
•10-bit characters
•10-bit pre-encoded characters (pre-scrambled or
pre-encoded)
•12-bit pre-encoded characters (pre-scrambled or
pre-encoded)
The bit numbering and content of the parallel transmit interface
is shown in Table 1. When operated with the 8B/10B Encoder
bypassed, the TXSC/D and RXSC/D bits are ignored.
Synchronous Pre-encoded
In synchronous pre-encoded mode, both the Transmit FIFO
and the 4B/5B encoder are bypassed, and data passes directly from the Transmit Input Register to the Serializer. The Serializer operates synchronous to REFCLK, which is multiplied
by 10 or 5 when BYTE8/10 is HIGH (as selected by the SPDSEL and RANGESEL inputs) to generate the serial data bitclock. In this mode, part of the TXCMD bus inputs are used as
part of the data input bus. To place the CY7C9689 into synchronous modes, FIFOBYP must be LOW.
The HOTLink Transceiver serial interface provides a seamless
interface to various types of media. A minimal number of external passive components are required to properly terminate
transmission lines and provide LVPECL loads. For power supply decoupling, a single capacitor (in the range of 0.02 mF to
0.1 mF) is required per power/ground pair. Additional information on interfacing these components to various media can be
found in the HOTLink Design Considerations application note.
This mode is usually used for products containing external encoders or scramblers, that must meet specific protocol requirements. The host system is required to provide new data at
every rising edge of the REFCLK (along with TXEN) to maintain the data stream. If TXEN is not asserted, the Serializer is
loaded with JK or LM sync characters.
CY7C9689 TAXI HOTLink Transmit-Path
Operating Mode Descriptions
In this mode the LSB of each input character (TXDATA[0]) is
shifted out first, followed sequentially by TXDATA[1] through
TXDATA[9] (TXDATA[11] when BYTE8/10 is LOW).
The TAXI HOTLink Transmitter can be configured into several
operating modes, each providing different capabilities and fitting different transmission needs. These modes are selected
using the FIFOBYP, ENCBYP and BYTE8/10 inputs on the
CY7C9689 Transceiver. These modes can be reduced to five
primary classes:
•Synchronous Encoded
•Synchronous Pre-encoded
•Asynchronous Encoded
•Asynchronous Pre-encoded
Asynchronous Encoded
In Asynchronous Encoded mode, both the Transmit FIFO and
the Encoder are enabled. This provides 256 characters of data
buffering. The Serializer operates synchronous to REFCLK,
which is multiplied by 2.5, 5, or 10 to generate the serial data
bit-clock (as selected by SPDSEL and RANGESEL). In this
mode the TXRST and TXHALT inputs are interpreted.
This mode supports the same Input Register mapping as Synchronous Encoded mode. Because both the Transmit FIFO
35
CY7C9689
The Violation (VLTN) output indicates a code violation has occured. When the VLTN output is asserted HIGH, this indicates
a transmission error is detected in the character at the current
transfer clock cycle.
and Encoder are enabled, the input FIFO may be loaded at any
rate supported by the FIFO (up to 50 MHz), without generating
any decoder errors at the receive end of the link.
CY7C9689 TAXI HOTLink Receive-Path
Operating Mode Descriptions
Synchronous Undecoded
In this mode, both the Receive FIFO and the 5B/4B, 6B/5B
Decoder are bypassed, and data passes directly from the Deserializer to the output register. The Deserializer operates synchronous to the recovered bit-clock, which is divided by 10 to
generate the output RXCLK clock. In this mode the RXRST
input is not interpreted and may be biased either HIGH or
LOW.
The HOTLink Receiver can be configured into several operating modes, each providing different capabilities and fitting different reception needs. These modes are selected using the
FIFOBYP, ENCBYP, BYTE8/10 inputs on the CY7C9689
Transceiver. These modes can be reduced to four primary
classes:
•Synchronous Decoded
•Synchronous Undecoded
•Asynchronous Decoded
•Asynchronous Undecoded
In all these modes, serial data is received at one of the differential line receiver inputs and routed to the Deserializer and
Framer. The PLL in the clock and data recovery block is used
to extract a bit-rate clock from the transitions in the data
stream, and uses that clock to capture bits from the serial
stream. These bits are passed to the Deserializer where they
are formed into 10- or 12-bit characters.
This mode is usually used for products containing external decoders or descramblers that must meet specific protocol requirements. New data is provided at the RXDATA outputs once
every rising edge of RXCLK. Received characters are not
checked for any specific coding requirements and no decoding
errors are reported.
Asynchronous Decoded
In Asynchronous Decoded mode, both the Receive FIFO and
the Decoder of the CY7C9689 are enabled. The deserializer
operates synchronous to the recovered bit-clock, which is divided by 10 to generate the Receive FIFO write clock. Characters are read from the Receive FIFO, using the external
RXCLK input, when addressed by CE and selected by RXEN.
In this mode the RXRST input is interpreted.
To align the incoming bit stream to the proper character boundaries, the Framer must be enabled by asserting RFEN HIGH.
The Framer logic-block checks the incoming bit stream for the
unique pattern that defines the character boundaries. This logic filter looks for the JK or LM (when BYTE8/10 is LOW) sync
character. Once a sync character is found, the Framer captures the offset of the data stream from the present character
boundaries, and resets the boundary to reflect this new offset,
thus framing the data to the correct character boundaries.
Asynchronous Decoded mode supports the same Output
Register mapping as the Synchronous Decoded mode. Because both the Receive FIFO and Decoder are enabled, the
output FIFO may be read at any rate supported by the FIFO,
however, if the Receive FIFO ever indicates a full condition
(RXFULL is asserted), data may be lost.
Since noise induced errors can cause the incoming data to be
corrupted, and since many combinations of corrupt and legal
data can create an aliased sync character, the framer may also
be disabled by deasserting RFEN LOW.
Asynchronous Undecoded
In Asynchronous Undecoded modes, the Receive FIFO is enabled. This means that all characters received from the serial
interface are written to the Receive FIFO before being passed
to the output register. The Deserializer operates synchronous
to the recovered bit-clock, which is divided by 10 (or 12) to
generate the Receive FIFO write clock. Data is read from the
Receive FIFO, using the RXCLK input clock, when addressed
by CE and selected by RXEN.
Synchronous Decoded
In these modes, the Receive FIFO is bypassed, while the
5B/4B, 6B/5B Decoder is enabled. Framed characters output
from the Deserializer are decoded, and passed directly to the
Receive Output Register. The Deserializer operates synchronous to the recovered bit-clock, which is divided by 10, generate the output RXCLK clock. In this mode the RXRST input is
not interpreted and may be biased either HIGH or LOW.
These modes are usually used for products containing external decoders or descramblers, that must meet specific protocol
requirements. New data may be read from the Receive FIFO
any time that the FIFO status flags indicate a non-empty condition (RXEMPTY is deasserted). To ensure that data is not
lost, the Receive FIFO must be read faster than data is loaded
into the Receive FIFO.
These modes are usually used for products that must meet
specific protocol requirements. New decoded characters are
provided at the RXDATA outputs once every rising edge of
RXCLK. If RXEMPTY is asserted LOW, the characters on the
RXCMD output register is a JK or LM sync character, and the
discard policy is set to non-0. Because the decoder is now
enabled, all received characters are checked for compliance to
the 4B/5B decoding rules.
If the receiver is to provide framed characters, it is necessary
for the transmit end to include JK or LM sync characters in the
data stream. This can be done by:
•operating the transmitter in encoded mode and writing JK or
LM characters into the data stream,
•operating the transmitter in pre-encoded mode and writing
the 10-bit value for an encoded JK (1100010001) or LM
(011000100011) character to the data stream
•not enabling the transmitter when it is operated in synchronous mode, or by allowing the transit FIFO to go empty when
it is operated in asynchronous mode.
Output Register Mapping
The RXDATA[11:0] output bus is mapped into a character consisting of eight bits of data and four bits of command, or ten
bits of data and two bits of command. An accompanying
RXSC/D bit identifies the character as either command or
data.
36
CY7C9689
the recognition occurs in the middle of a data field, the following data is not transmitted at that time, but remains in the
Transmit FIFO. Once the TXBISTEN signal is removed, the
data in the Transmit FIFO is again available for transmission.
To ensure proper data handling at the destination, the transmit
host controller should either use TXHALT to prevent transmission of data at specific boundaries, or allow the Transmit FIFO
to completely empty before enabling BIST.
BIST Operation and Reporting
The CY7C9689DX HOTLink Transceiver incorporates the
same Built-In Self-Test (BIST) capability. This link diagnostic
uses a Linear Feedback Shift Register (LFSR) to generate a
511-character repeating sequence that is compared, character-for-character, at the receiver.
BIST mode is intended to check the entire high-speed serial
link at full link-speed, without the use of specialized and expensive test equipment. The complete sequence of characters
used in BIST are documented in Table 4.
With transmit BIST enabled, the Transmit FIFO remains available for loading of data. It may be written up to its normal maximum limit while the BIST operation takes place. To allow removal of stale data from the Transmit FIFO, it may also be reset
during a BIST operation. The reset operation proceeds as documented, with the exception of the information presented on
the TXEMPTY FIFO status flag. Since this flag is used to
present BIST loop status, it continues to reflect the state of the
transmit BIST loop status until TXBISTEN is no longer recognized internally. The completion of the reset operation may still
be monitored through the TXFULL FIFO status flag.
BIST Enable Inputs
There are separate BIST enable inputs for the transmit and
receive paths of the CY7C9689. These inputs are both active
LOW; i.e., BIST is enabled in its respective section of the device when the BIST enable input is determined to be at a logic0 level. Both BIST enable inputs are asynchronous; i.e., they
are synchronized inside the CY7C9689 to the internal state
machines.
The TXEMPTY flag, when used for transmit BIST progress
indication, continues to reflect the active HIGH or active LOW
settings determined by the UTOPIA or Cascade timing model
selected by EXTFIFO; i.e., when configured for the Cascade
timing model, the TXEMPTY and TXFULL FIFO flags are active HIGH, when configured for the UTOPIA timing model the
TXEMPTY and TXFULL FIFO flags are active LOW. The illustration in Figure 5 uses the UTOPIA conventions.
BIST Transmit Path
The transmit path operation with BIST is controlled by the
TXBISTEN input and overrides most other inputs (see Figure
5). When the Transmit FIFO is enabled (not bypassed) and
TXBISTEN is recognized internally, all reads from the Transmit
FIFO are suspended and the BIST generator is enabled to
sequence out the 511 character repeating BIST sequence. If
TXCLK
TXBISTEN
TXEMPTY
TXHALF
TXFULL
Start of TX BIST
BIST
LOOP
Don’t Care
LOW to enable VLTN reads
Ignore these outputs
ERROR
Start of RX
BIST Wait
Start of RX
BIST match
Forced to indicate EMPTY by BIST
BIST
LOOP
Enable RX BIST
CE
RXEN
RXDATA[9:0]
RXSC/D
RXCMD[1:0]
VLTN
RXEMPTY
RXHALF
RXFULL
RXBISTEN
RXCLK
Figure 5. Built-In Self-Test Illustration
37
OUTB±
TXCMD[1:0]
TXSC/D
TXDATA[9:0]
TXEN
REFCLK
LOW to enable FIFO Flags
OUTA±
CY7C9689
Enable TX BIST
INA±
INB±
A/B
HIGH to select A
CY7C9689
When TXBISTEN is first recognized, the TXEMPTY flag is
clocked to a reset state, regardless of the addressed state of
the Transmit FIFO (if CE is LOW or not), but is not driven out
of the part unless CE has been sampled asserted (LOW). Following this, on each completed pass through the BIST loop,
the TXEMPTY flag is set for one interface clock period (TXCLK
or REFCLK).
the BIST pattern. Then RXFULL is deasserted for the duration
of the BIST pattern, pulsing asserted for one RXCLK period
on the last symbol of each BIST loop. If 14 of 28 consecutive
characters are received in error, RXFULL returns to the set
state until the start of a BIST sequence is again detected.
Just like the BIST status flag on the transmit data path, the
RXFULL flag captures the asserted states, and keeps them
until they are read. This means that if the status flag is not read
on a regular basis, events may be lost.
The TXEMPTY flag remains set until the interface is addressed and the state of TXEMPTY has been observed. If the
device is not addressed (CE is not sampled LOW), the flag
remains set internally regardless of the number of TXCLK
clock cycles that are processed. If the device status is not
polled on a sufficiently regular basis, it is possible for the host
system to miss one or more of these BIST loop indications.
The detection of errors is presented on the VLTN output. Unlike the RXFULL FIFO status flag, the active state of this output
is not controlled by the EXTFIFO input. With the Receive FIFO
enabled, these outputs should operate the same as the
RXFULL flag, with respect to preserving the detection state of
an error until it is read.
A pass through the loop is defined as that condition where the
Encoder generates the 0x00 (where 0x denotes Hex number,
e.g. 0x00 denotes HEX00) state. Depending on the initial state
of the BIST LFSR, the first pass through the loop may occur at
substantially less than 511 character periods. Following the
first pass, as long as TXBISTEN remains LOW, all remaining
passes are exactly 511 characters in length.
Unlike the RXFULL flag, which only needs the CY7C9689 to
be addressed (CE sampled LOW by RXCLK) to enable the
RXFULL three-state driver, and an RXCLK to “read” the flag,
the VLTN output requires a selection (assertion of RXEN while
addressed) to enable the RXDATA bus three-state drivers. The
selection process is necessary to ensure that a multi-PHY implementation does not enable multiple VLTN drivers at the
same time.
When the Transmit FIFO is bypassed, the interface is clocked
by the REFCLK signal instead of TXCLK. While the active or
asserted state of the TXEMPTY signal is still controlled by the
EXTFIFO, the state of any completed BIST loops is no longer
preserved. Instead, the TXEMPTY flag reflects the dynamic
state of the BIST loop progress, and is asserted only once
every 511 character periods. If the interface is not addressed
at the time that this occurs, then the FIFO status flags remain
in a high-Z state and the loop event is lost.
When the Receive FIFO is bypassed, the interface is clocked
by the RXCLK output signal. While the active or asserted state
of the RXFULL signal is still controlled by the EXTFIFO input,
the state of any completed BIST loops or detected errors are
no longer preserved. Instead, the RXFULL flag reflects the
dynamic state of the BIST loop progress, and is asserted only
once every 511 character periods. If the interface is not addressed at the time that this occurs, then the FIFO status flags
remain in a high-Z state and the loop event is lost. This is also
true of the VLTN output, such that if the CY7C9689 receive
path is not selected to enable the RXDATA bus three-state drivers, the detection of a BIST miscompare is lost.
BIST Receive Path
The receive path operation in BIST is similar to that of the
transmit path. While the Receive FIFO is enabled (not bypassed) and RXBISTEN is recognized internally, all writes to
the Receive FIFO are suspended.
BIST Three-state Control
Any data present in the Receive FIFO when RXBISTEN is recognized remains in the FIFO and cannot be read until the BIST
operation is complete. The data in the Receive FIFO remains
valid, but is NOT available for reading through the host parallel
interface. This is because the error output indicator for receive
BIST operations is the VLTN signal, which is normally part of
the RXDATA bus. To prevent read operations while BIST is in
operation, the RXEMPTY and RXHALF flags are forced to indicate an Empty condition. Once RXBISTEN has been removed and recognized internally, the Receive FIFO status
flags are updated to reflect the current content status of the
Receive FIFO.
When BIST is enabled on either the transmitter or the receiver,
the three-state enable signals for the BIST status flags and
error indicators work the same as for normal data processing.
The output drivers for the BIST status that is presented on
FIFO status flags are only enabled when CE has been sampled asserted (LOW) by the respective clock (TXCLK, RXCLK,
or REFCLK).
To access the BIST error information, it is necessary to perform a read cycle of the addressed receiver. This means that
CE must be LOW to enable the receiver (Rx_Match), and
RXEN must be asserted from HIGH to LOW to select the device. Because the part is in BIST, no data is read from the
FIFO, but the data bus is driven. This allows the VLTN indicator
to be driven onto the RXDATA bus. So long as RXEN remains
asserted, the receiver stays selected, the data bus remains
driven, and VLTN has meaning.
To allow removal of stale data from the Receive FIFO, it may
be reset during a BIST operation. The reset operation proceeds as documented, with the exception that the RXEMPTY
and RXHALF status flags already indicate an empty condition.
The RXFULL flag is used to present BIST progress. The active
(asserted) state on RXFULL (and RXEMPTY) remain controlled by the present operating mode and interface timing
model (UTOPIA or Cascade).
Bus Interfacing
The parallel transmit and receive host interfaces to the
CY7C9689 are configurable for either synchronous or asynchronous operation. Each of these configurations supports
two selectable timing and control models of Shared Bus or
Cascade.
When RXBISTEN has been recognized, RXFULL becomes
the receive BIST loop indicator (regardless of the logic state of
FIFOBYP). When RXBISTEN is first recognized, the RXFULL
flag is clocked to a set state, regardless of the addressed state
of the Receive FIFO (if CE is sampled LOW or not). Following
this, RXFULL remains set until the receiver detects the start of
38
CY7C9689
ta/command to/from Slaves (CY7C9689) on the shared bus
(see Figure 6).
All asynchronous bus configurations have the internal Transmit
and Receive FIFOs enabled. This allows data to be written or
read from these FIFOs at any rate up to the maximum 50-MHz
clock rate of the FIFOs. All internal operations of the
CY7C9689 do not use the external TXCLK or RXCLK, but instead make use of synthesized derivatives of REFCLK for
transmit path operations and a recovered character clock for
receive path operations.
Bus
Master
CEn
CE1
All synchronous bus configurations require the bus interface
operations to be synchronous to REFCLK on the transmit path
and the recovered clock (output as RXCLK) on the receive
path. The internal FIFOs are bypassed in all synchronous
modes.
CE2
CY7C9689
The two supported timing and control models are Shared Bus
and Cascade. The Shared Bus is based on the timing model
of a FIFO with active LOW FIFO status flags and read/write
enables.
The Cascade timing model is a modification of the Shared Bus
model that changes the flags and FIFO read/write enables to
active HIGH. This model is present primarily to allow depth
expansion of the internal FIFO by direct coupling to external
CY7C42x5 synchronous FIFOs. To allow this direct coupling,
the cycle-to-cycle timing between the transmit and receive enables (TXEN and RXEN) are also modified to ensure correct
data transfer.
CY7C9689
TXDATA/TXCMD
RXDATA/RXCMD
Status, Control
............
CY7C9689
Figure 6. Shared Bus Architecture
The data bus (TXDATA, RXDATA), command bus (TXCMD,
RXCMD) and FIFO status flags (TXFULL, RXEMPTY, etc.) of
each CY7C9689 on the shared bus can be connected together
respectively. Each Slave can be assigned an address. The address of each Slave can be decoded by a decoder which drives
the CE input of each Slave. The bus Master will poll each Slave
by selecting (or “Addressing”) the device, and sample the FIFO
flags. Depending on the FIFOs status on each Slave device,
the Master can schedule read accesses to Slaves which have
data in the RXFIFOs, and write accesses to Slaves which have
room in the TXFIFOs. While data is being transferred on the
data/command bus, the bus Master can continue to poll each
Slave device independently.
These four configurations of bus operation and timing/control
can all be used with or without external FIFOs. Depending on
the specific mode selected, the amount of external hardware
necessary to properly couple the CY7C9689 to state machines or external FIFOs is minimal in all cases, and may be
zero if the proper configuration is selected.
With only minor exceptions, all configurations of the
CY7C9689 in the Shared Bus mode borrowed concepts from
the ATM Forum’s UTOPIA Bus operation. concepts of addressing and selection to control the enabled/disabled state of the
output drivers, and when data can be written to or read from
the part.
Device Selection
All actions on the Shared Bus interface are controlled by the
Chip Enable and selection states of the interface. These states
control the read and write access to the Receive and Transmit
FIFOs, access to the FIFO status flags, reset of the Transmit
and Receive FIFOs, and read and write access to the Serial
Address Register. The CY7C9689 supports the concept of an
“address match” through a single Chip Enable (CE) input.
Shared Bus Interface Concept
The CY7C9689 Parallel Interface is designed for interfacing to
a Shared Bus. The maximum TXCLK and RXCLK frequency
is 50 MHz, which provides a total bandwidth of 50Million characters per second in each direction. More than two CY7C9689
can be serviced on the same bus at full serial line speed.
Address Match and FIFO Flag Access
The CY7C9689 makes use of a single active-LOW Chip Enable (CE) to generate address-match conditions. This allows
multiple CY7C9689 devices to share a common bus, with device output three-state controls being managed by either an
address match condition (CE sampled LOW), or by a selection
state.
The CY7C9689 is designed to be the Slave in Master-Slave
type of shared bus architecture. Generally, the bus Master (a
Medium Access Device, MAC) is a higher layer device that
sources out going data/command and sinks incoming da-
The Transmit and Receive FIFO flag output drivers are enabled in any TXCLK, REFCLK, or RXCLK cycle following CE
being sampled asserted (LOW) by the rising edge of the respective clock. The CE input is sampled separately by the
clocks for the transmit and receive interfaces, which allows
these clocks to be both asynchronous to each other, and to
operate at different clock rates. An example of both Transmit
and Receive FIFO flag access is shown in Figure 7.
When the Transmit FIFO is enabled (FIFOBYP is HIGH) and
CE is sampled LOW by the rising edge of TXCLK, the output
drivers for the TXFULL and TXEMPTY FIFO flags are enabled.
When CE is sampled HIGH by the rising edge of TXCLK, these
same output drivers are disabled.
39
CY7C9689
more clock cycles prior to the selection control signal being
sampled asserted.
TXCLK
Transmit Data Selection
CE
Asynchronous With Shared Bus Timing and Control
(Transmit FIFO Enabled)
TXFULL
When CE is sampled LOW and TXRST is sampled HIGH by
the rising edge of TXCLK, a Tx_Match condition is generated.
This Tx_Match condition continues until CE is sampled HIGH
or TXRST is sampled LOW at the rising edge of TXCLK. When
a Tx_Match (or Tx_RstMatch) condition is present, the
TXEMPTY and TXFULL output drivers are enabled. When a
Tx_Match (or Tx_RstMatch) condition is not present, these
same drivers are disabled (High-Z).
Va lid
Transmit Port Addressing
RXCLK
The selection state of the Transmit FIFO is entered when a
Tx_Match condition is present, and TXEN transitions from
HIGH to LOW. Once selected, the Transmit FIFO remains selected until TXEN is sampled HIGH by the rising edge of
TXCLK. In the selected state, data present on the TXDATA
inputs is captured and stored in the Transmit FIFO. This transmit interface selection process is shown in Figure 8.
CE
Valid
RXEMPTY
Receive Port Addressing
Figure 7. FIFO Flag Driver Enables
Synchronous With Shared Bus Timing and Control
(Transmit FIFO Bypassed)
When the Transmit FIFO is bypassed (FIFOBYP is LOW and
not in byte-packed mode) and CE is sampled LOW by the rising edge of REFCLK, the output drivers for the TXFULL and
TXEMPTY FIFO flags are enabled. When CE is sampled
HIGH by the rising edge of REFCLK, the FIFO flag output drivers are disabled.
When the Transmit FIFO is bypassed (FIFOBYP is LOW and
not in byte-packed mode), the CY7C9689 must still be selected to write data into the Transmit Input Register.
When CE is sampled LOW and TXRST is sampled HIGH by
the rising edge of REFCLK, a Tx_Match condition is generated. This Tx_Match condition continues until CE is sampled
HIGH or TXRST is sampled LOW at the rising edge of TXCLK.
When a Tx_Match (or Tx_RstMatch) condition is present, the
TXEMPTY and TXFULL output drivers are enabled (with the
Transmit FIFO bypassed, the status flags normally indicate an
Empty condition). When a Tx_Match (or Tx_RstMatch) condition is not present, these same drivers are disabled (High-Z).
When CE is sampled LOW by the rising edge of RXCLK (input
or output), the output drivers for the RXFULL and RXEMPTY
FIFO flags are enabled. When CE is sampled HIGH by the
rising edge of RXCLK, the FIFO flag output drivers are disabled.
Device Selection
The concept of selection is used to control the access to the
transmit and receive parallel-data ports of the device. There
are three primary types of selection:
•Transmit data selection (with and without internal Transmit
FIFO)
•Receive data selection (with and without internal Receive
FIFO)
•Continuous selection (for either or both transmit and receive
interfaces)
In addition to these normal selection types, there are two additional sequences that are used to control the internal Transmit and Receive FIFOs reset operations, and to control
read/write access to the Serial Address Register:
•Transmit reset sequence
•Receive reset sequence
Of these operations, the transmit data selection and transmit
reset sequence are mutually exclusive and cannot exist at the
same time. The receive data selection and receive reset sequence are also mutually exclusive and cannot exist at the
same time. Either transmit operation can exist at the same time
as either receive operation.
The selection state of the Transmit Input Register is entered
when a Tx_Match condition is present, and TXEN transitions
from HIGH to LOW. Once selected, the transmit input register
remains selected until TXEN is sampled HIGH by the rising
edge of REFCLK. In the selected state, data present on the
TXDATA inputs is captured in the Transmit Input Register and
passed to the Serializer or Encoder (as selected by the
ENCBYP input). This transmit interface selection process is
shown in Figure 9.
When the 4B/5B Encoder is enabled and data is not written to
the Transmit Input Register, the data stream is automatically
padded with JK or LM SYNC characters. When the 4B/5B,
5B/6B Encoder is disabled and no data is written to the Transmit Input Register, JK or LM SYNC characters are also automatically padded with SYNC characters.
Receive Data Selection
Asynchronous With Shared Bus Timing and Control
(Receive FIFO Enabled)
When CE is sampled LOW and RXRST is sampled HIGH by
the rising edge of RXCLK input, an Rx_Match condition is generated. This Rx_Match condition continues until CE is sampled
HIGH or RXRST is sampled LOW at the rising edge of RXCLK
input. When an Rx_Match (or Rx_RstMatch) condition is
present, the RXEMPTY and RXFULL output drivers are en-
All normal forms of selection require that an Chip Enable must
be asserted (CE sampled LOW) either at the same time as the
selection control signal being sampled asserted, or one or
40
CY7C9689
TXCLK
TXRST
CE
[46]
Tx_Match
Note 47
TXEN
Tx_Selected
[46]
TXDATA/TXCMD
D1
(Shared Bus Timing)
TXDATA/TXCMD
(Cascade Timing)
TXFULL
Not Full
D2
D3
D1
D2
D3
Not Full
Note 47
Figure 8. Transmit Selection with Transmit FIFO Enabled
REFCLK
TXRST
CE
Tx_Match
[46]
Note 47
TXEN
Tx_Selected
[46]
TXDATA/TXCMD
D1
(Shared Bus Timing)
TXDATA/TXCMD
(Cascade Timing)
TXFULL
Not Full
D2
D3
D1
D2
D3
Not Full
Note 47
Figure 9. Transmit Selection with Transmit FIFO Bypassed
Notes:
46.Signals labeled in italics are internal to the CY7C9689.
47.Signals shown as dotted lines represent the differences in timing and active state of signals when operated in Cascade Timing.
41
CY7C9689
ister remains selected until RXEN is sampled HIGH by the
rising edge of RXCLK output. In the selected state, the output
drivers for the RXDATA outputs are enabled, and new data is
presented to the RXDATA bus on every clock cycle.
abled. When an Rx_Match (or Rx_RstMatch) condition is not
present, these same drivers are disabled (High-Z).
The selection state of the Receive FIFO is entered when an
Rx_Match condition is present, and RXEN transitions from
HIGH to LOW. Once selected, the Receive FIFO remains selected until RXEN is sampled HIGH by the rising edge of
RXCLK input. The selected state initiates a read cycle from the
Receive FIFO and enables the Receive FIFO data onto the
RXDATA bus. This receive interface selection process is
shown in Figure 10.
Continuous Selection
Continuous Selection is a specialized form of selection which
does not require sequenced assertion of CE and TXEN or
RXEN to select the device for data transfers. In this Continuous
Selection mode, the CE and associated TXEN or RXEN enable signal must be asserted when the device is powered up
or during assertion of RESET. So long as these signals remain
asserted, the device remains selected and data is accepted
and presented on every clock cycle.
Synchronous With UTOPIA Timing and Control
(Receive FIFO Bypassed)
When the Receive FIFO is bypassed (FIFOBYP is LOW), the
CY7C9689 must still be selected to enable the output drivers
for the RXDATA bus. With the Receive FIFO bypassed, RXCLK
becomes a synchronous output clock operating at the character rate.
NOTE: The use of continuous selection makes it impossible to
reset the respective internal FIFOs, or to access the Serial
Address Register.
FIFO Reset Address Match
When CE is sampled LOW and RXRST is sampled HIGH by
the rising edge of RXCLK output, an Rx_Match condition is
generated. This Rx_Match condition continues until CE is
sampled HIGH or RXRST is sampled LOW at the rising edge
of RXCLK.
When CE and TXRST are both LOW, and this condition is
sampled by the rising edge of TXCLK, a Tx_RstMatch condition is generated. This Tx_RstMatch condition continues until
CE or TXRST is sampled HIGH by the rising edge of TXCLK.
When a Tx_RstMatch (or Tx_Match) condition is present, the
TXEMPTY and TXFULL output drivers are enabled (just as in
a normal Tx_Match condition). When a Tx_RstMatch (or
Tx_Match) condition is not present, these same drivers are
disabled (High-Z). The Transmit FIFO reset Address Match is
shown in Figure 11. Note that although TXRST remains LOW
for more than one clock cycle, the Tx_RstMatch does not because the CE signal is no longer asserted (LOW).
When an Rx_Match (or Rx_RstMatch) condition is present,
the RXEMPTY and RXFULL output drivers are enabled. With
the Receive FIFO bypassed, these flags normally indicate a
non-empty condition but may indicate empty if a JK or LM
SYNC character is present in the output register and the receiver discard policy is non-0. When an Rx_Match (or
Rx_RstMatch) condition is not present, these same drivers are
disabled (High-Z).
When CE and RXRST are both LOW, and this condition is
sampled by the rising edge of RXCLK, an Rx_RstMatch condition is generated. This Rx_RstMatch condition continues until CE or RXRST is sampled HIGH, at the rising edge of RX-
The selection state of the Receive Output Register is entered
when an Rx_Match condition is present, and RXEN transitions
from HIGH to LOW. Once selected, the Receive Output Reg-
RXCLK
RXRST
CE
[46]
Rx_Match
RXEN
Rx_Selected
Note 47
[46]
D1
RXDATA/RXCMD
Not Empty
RXEMPTY
D2
D3
Not Empty
Note 47
Figure 10. Receive Selection with Receive FIFO Enabled
42
CY7C9689
Transmit FIFO Reset Sequence
TXCLK
The Transmit FIFO reset sequence (see Figure 13) is started
when TXRST and CE are first sampled LOW by the rising edge
of TXCLK. Because a Tx_RstMatch condition is present, the
Transmit FIFO flags are asserted and can be used to track the
status of any Transmit FIFO reset in progress. Once the reset
sequence has reached its maximum count (eight TXCLK cycles), the Transmit FIFO flags are asserted to indicate a FULL
condition (TXEMPTY is deasserted, and both TXHALF and
TXFULL are asserted). This indicates that the Transmit FIFO
reset has been recognized by the Transmit Control State Machine and that a reset has been started. However, if the TXEN
is asserted prior to or during the assertion and sampling of
TXRST, the reset sequence is inhibited until TXEN is removed.
TXRST
CE
Tx_RstMatch
Tx_Match
[46]
[46]
TXFULL
Va lid
NOTE: The FIFO FULL state forced by the reset operation is
different from a FULL state caused by normal FIFO data
writes. For normal FIFO write operations, when FULL is first
asserted, the Transmit FIFO must still accept up to four additional writes of data. When a FULL state is asserted due to a
Transmit FIFO reset operation, the FIFO will not accept any
additional data.
Figure 11. Transmit FIFO Reset Address Match
RXCLK
The Transmit FIFO reset does not complete until the external
reset condition is removed. This can be removed by deassertion of either TXRST or CE. If CE is deasserted (HIGH) to
remove the reset condition, the Transmit FIFO flag’s drivers are
disabled, and the Transmit FIFO must be addressed at a later
time to validate completion of the Transmit FIFO reset. If
TXRST is deasserted (HIGH) to remove the reset condition,
the Tx_RstMatch is changed to a Tx_Match, and the Transmit
FIFO status flags remain driven. The Transmit FIFO reset operation is complete when the Transmit FIFO flags indicate an
EMPTY state (TXEMPTY is asserted and both TXHALF and
TXFULL are deasserted). A valid Transmit FIFO reset sequence is shown in Figure 13.
RXRST
CE
Rx_RstMatch
Rx_Match
[46]
[46]
RXEMPTY
Valid
Valid
Figure 12. Receive FIFO Reset Address Match
Here the TXRST and CE are asserted (LOW) at the same
time. When these signals are both sampled LOW by TXCLK,
a Tx_RstMatch condition is present. With TXEN deasserted
(HIGH), the Transmit FIFO is not selected for data transfers.
This Tx_RstMatch condition must remain for eight TXCLK cycles to initiate the Tx_FIFO_Reset. Following this the TXFULL
FIFO status flag is asserted to indicate that the Transmit FIFO
reset sequence has completed and that a Transmit FIFO reset
is in progress.
CLK. When an Rx_RstMatch (or Rx_Match) condition is
present, the RXEMPTY and RXFULL output drivers are enabled. When an Rx_RstMatch (or Rx_Match) condition is not
present, these same drivers are disabled (High-Z). The Receive FIFO reset Address Match is shown in Figure 12. Note
that while the FIFO flags remain asserted for more than one
clock cycle, this is due to an Rx_Match condition, not a continuation of the Rx_RstMatch.
When the TXRST signal is deasserted (HIGH), CE remains
LOW to allow the FIFO status flags to be driven. This allows
the completion of the reset operation to be monitored. To allow
better multi-tasking on multi-PHY implementations, it is possible to deassert CE (HIGH) as soon as the FULL state is indicated. The FIFO reset operation will complete and the EMPTY
state (indicating completion of the reset operation) can be detected during a separate polling operation.
FIFO Reset Sequence
On power-up, the Transmitter and Receiver FIFOs are cleared
automatically. If the usage of the FIFOs in specific operating
modes results in stale or unwanted data, this data can be
cleared by resetting the respective FIFO. Data in the Transmit
FIFO will empty automatically if it is enabled to read the FIFO
(assuming TXHALT is not LOW). Stale received data can be
“flushed” by reading it, or the Receive FIFO can be reset to
remove the unwanted data.
For those links implemented with a single PHY, it is possible to
hardwire CE LOW and still perform normal accesses and reset
operations. This is shown in Figure 14. In a single-PHY implementation, a Transmit FIFO reset can never be initiated with
TXEN asserted at the same time as TXRST. Since CE is
always LOW, any assertion of TXEN causes the Transmit FIFO
to be selected, clearing the reset counter.
The Transmit and Receive FIFOs are reset when the
Tx_RstMatch or Rx_RstMatch condition remains present for
eight consecutive clock cycles. Any disruption of the reset sequence prior to reaching the eight cycle count, either by removal of CE or the respective TXRST or RXRST, or assertion
of the associated TXEN or RXEN, terminates the sequence
and does not reset the FIFO. Because CE must remain asserted during the reset sequence, the addressed FIFO flags remain driven during the entire sequence.
Figure 15 shows a sequence of input signals which will not
produce a FIFO reset. In this case TXEN was asserted to select a Transmit FIFO for data transfers. Because TXEN remains active, the assertion of CE and TXRST does not initiate
43
CY7C9689
TX C LK
T X R ST
Note 48
TX EN
CE
T x _R stM atch
[49]
[49]
T x_ M atch
[49]
T x _ F IF O _ R eset
TXFULL
Note 48
N o t F u ll
F u ll
Figure 14. Transmit FIFO Reset Sequence with Constant CE
a reset operation. This is shown by the TXFULL flag remaining
HIGH (deasserted) following what would be the normal expi-
ration of the seven-state reset counter.
TX CLK
TX RST
TX EN
Note 48
CE
[49]
T x _ R stM a tc h
[49]
T x _M a tc h
T x_ F IF O _R eset
[49]
TX FU LL
Note 48
N o t F u ll
Figure 13. Transmit FIFO Reset Sequence
Notes:
48. Signals shown as dotted lines indicate timing and levels when configured for external FIFOs (EXTFIFO is HIGH).
49. Signal names listed in italics are internal signals, shown for reference only.
44
F u ll
CY7C9689
TX C LK
T X R ST
Note 48
TX EN
CE
T x _R stM atch
[49]
[49]
T x_ M atch
T x_ F IF O _ R eset
[49]
Note 48
T X FU L L
N o t F u ll
Figure 15. Invalid Transmit FIFO Reset Sequence with TXEN Asserted
Receive FIFO Reset Sequence
EMPTY state to prohibit additional reads from the FIFO. Unlike
the Transmit FIFO, where the internal completion of the reset
operation is shown by first going FULL and later going EMPTY
when the internal reset is complete, there is no secondary indication of the completion of the internal reset of the Receive
FIFO. The Receive FIFO is usable as soon as new data is
placed into it by the Receive Control State Machine.
The Receive FIFO reset sequence operates (for the most part)
the same as the Transmit FIFO reset sequence. The same
requirements exist for the assertion state of RXRST and selection of the interface. A sample Receive FIFO reset sequence is shown in Figure 16. Upon recognition of a Receive
FIFO reset, the Receive FIFO flags are forced to indicate an
45
CY7C9689
RX CLK
RX RST
RXEN
Note 48
CE
R x_ R stM a tc h
[49]
[49]
R x_ M atch
R x _F IF O _ R e se t
R X E M PT Y
[49]
Note 48
N o t E m p ty
Figure 16. Receive FIFO Reset Sequence
46
E m p ty
CY7C9689
Printed Circuit Board Layout Suggestions
Power Supply Bypass
0.01-µF MLC X7R
1206 Chip Cap (4 sites)
INA±
OUTA±
OUTB±
INB±
Power Supply Bypass
0.01-µF MLC X7R
CURSETB
Resistor
CURSETA
Resistor
Power Supply Bypass
0.01-µF MLC X7R
1206 Chip Cap (2 sites)
RXSC/D
REFCLK
CY7C9689-AC
CY7C9689-AC
Power Supply Bypass
0.01-µF MLC X7R
RESET
Power Supply Bypass
0.01-µF MLC X7R
Via to V DD plane
Via to VSS plane
Other layouts, including cases with components mounted on
the reverse side would work as well.
This is a typical printed circuit board layout showing example
placement of power supply bypass components and other
components mounted on the same side as the CY7C9689.
47
CY7C9689
Ordering Information
Ordering Code
Package Name
Package Type
Operating Range
CY7C9689-AC
A100
100-Lead Thin Quad Flat Pack
Commercial
CY7C9689-AI
A100
100-Lead Thin Quad Flat Pack
Industrial
Document #: 38-00758-*C
Package Diagram
100-Pin Thin Plastic Quad Flat Pack (TQFP) A100
51-85048-A
HOTLink is a registered trademark of Cypress Semiconductor, Inc.
AMD, TAXI, and TAXIchip are trademarks of Advanced Micro Devices. Inc.
©Cypress Semiconductor Corporation, 2000. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.