ILI95-E3 Series

ILI95-E3
Series
Intelligent Loop
Interface-Main Board
Description
ILI95-MB-E3
The Gamewell-FCI, Intelligent Loop Interface95-Main
Board (ILI95-MB-E3) is the main circuit interface for the
following E3 Series® Systems.
• E3 Series Expandable Emergency Evacuation System
• E3 Series Combined Fire and Mass Notification System
With its state-of-the-art 32 bit RISC processor, this compact
“panel on a board” provides a powerful addition to
Gamewell-FCI’s single pair conductor solutions. This intuitive design provides the following features:
• 2 signaling line circuits
• auxiliary relay functions
• 2 notification appliance
• auxiliary power output
circuits
• local energy city box output
These features, combined with a built-in network and serial
protocols, allow this module to support a host of new and
existing products, resulting in a building block approach to
the fire alarm control panel design.
The ILI95-MB-E3 is network ready and occupies 64 nodes,
operating at 625K baud. In addition, the Addressable Node
Expander (ANX) board expands the network to 122 nodes.
When this sub-assembly is integrated with proven Broadband components, the result is a flexible yet powerful integrated audio solution. When the sub-assembly transmits to
remote locations, the optional RPT-E3 provides the ILI95MB-E3 with valuable signal boosting and transient protection, as well as provides connectivity using both wire and
fiber-optic cables.
The ILI95-MB-E3 provides 2 signaling line circuits and terminals for the connections to up to 126 Apollo detectors
and modules per SLC. The RS-485 interface can support
up to a total of 6 LCD-E3 and 16 ASM-16 and/or 16 ANU48 remote LED driver modules.
The ILI95-MB-E3 relay outputs include system alarm,
supervisory, and system trouble contacts. The ILI95-MB-E3
provides output for a local energy city master box or for a
remote location which is non power-limited. All other wiring
is Class 2 power-limited.
ILI95-MB-E3
Features
ILI95-MB-E3 and ILI95-S-E3:
Listed under UL® Standard 864, 9th Edition.
Listed under UL Standard UL2572 for Mass Notification.
Provides network ready integral 625K baud ARCNET.
115.2K baud RS-232.
Signaling line circuits with:
- 2 Class A, Style 6, 7* or Class B, Style 4 circuits
- 40 Character user-defined text per device
- Capacity of 126 analog/addressable devices per
loop
• 4100 Event History Log.
*Style 7 wiring requires the use of XP95-LI Isolator
Modules.
•
•
•
•
•
•
ILI95-MB-E3 Only:
• 2 notification appliance circuits, Class “A”, Style Z or
Class B, Style Y rated at 2.0 amps. per circuit.
• RS-485 supporting 16 ASM-16 switch modules and/or
ANU-48 LED driver modules.
• Alarm, trouble, and supervisory dry contacts Form “C”,
rated at 2 amp. @ 30 VDC (resistive).
• Supports six local/remote LCD-E3 annunciators and five
LCD-7100/RAN-7100 remote LED annunciators.
SIGNALING
FM
®
E3 Series is a registered trademark of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories Inc.
MEA
Approved
APPROVED FDNY #: 6175
S1869 3025415 COA # 231-06-E 7165-1703:0125
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
www.gamewell-fci.com
9021-60336 Rev. J page 1 of 2
©2014 by Honeywell International Inc. All rights reserved.
Specifications
ILI95-MB-E3
Operating Current:
Alarm Current:
0.050 amp
0.091 amp max.
ILI95-S-E3
Operating Current:
Alarm Current:
0.109 amp
0.11 amp
ILI95-MB-E3 and ILI95-S-E3
Operating Voltage:
ILI95-S-E3
ILI95-S-E3
The Intelligent Loop Interface95 - Expansion Board (ILI95S-E3) provides the E3 Series control panel with 2 additional signaling line circuits. The layout is similar to the
ILI95-MB-E3 except a number of components are omitted.
The ILI95-S-E3 occupies one node on the Broadband network. The ILI95-S-E3 provides 2 signaling line circuits and
terminals for the connections to up to 126 sensors /
modules.
Installation
Typically, the ILI95-MB-E3 or ILI95-S-E3 can be mounted
in the following E3 Series cabinets:
• Cabinet B and D, backbox
• Cabinet B, B-Slim-E3 sub-assembly plate
• Cabinet C, E3-ILI-C sub-assembly plate
• Cabinet C, E3-INCC-C sub-assembly plate
• Cabinet C, E3-INX-C sub-assembly plate
• Cabinet D, E3-INCC-D sub-assembly plate
• Cabinet D, E3-INX-D sub-assembly plate
24 VDC FWR (from the PM-9/
PM-9G Power Supply)
Operating Temperature: 32° to 120° F (0° to 49° C)
Relative Humidity:
0 to 93%, non-condensing
at 90° F (32° C)
Supervised
Class 2 Power-limited
SLC 40 Ohms maximum line impedance.
0.5 µf maximum line capacitance.
Ordering Information
Part Number Description
ILI95-MB-E3
ILI95-S-E3
Intelligent Loop Interface-Main Board
Intelligent Loop Interface-Expansion Board
For installation instructions on the ILI95-MB-E3 or
ILI95-S-E3, refer to the following documents:
• E3 Series® Expandable Emergency Evacuation
Installation/Operation Manual, Part Number: 9000-0574
• ILI95-MB-E3 Installation Instructions,
Part Number: 9001-0017
• ILI95-S-E3 Installation Instructions,
Part Number: 9001-0018
For information on the ANX, refer to the Data Sheet
Part Number: 9021-60497.
For additional information on the ILI-MB-E3 or ILI-S-E3,
refer to the following document:
• ILI-E3 Series Data Sheet, Part Number: 9020-0605