Data Sheet

600 Series
IdentiFlex 602
with Velociti®
Analog Addressable Control Panel
Description
The IdentiFlex 602 (IF602SS) with Velociti® is ideally
suited for small- to medium-sized installations at commercial, institutional, and industrial life-safety projects.
The IF602SS has all the features of today’s most advanced
life safety systems. The integration of analog and addressable hardwired circuits allows system engineers to customize panels and maximize efficiency for any application.
The IF602SS can monitor and control up to 396 intelligent
analog addressable input/output points. The interactive
operator’s display uses LED prompting for ease of programming and user operation. The alphanumeric display
and keypad simplify the field programming, or the download programming from a Windows®-based application.
The IF602’s housing was designed to be both aesthetically
pleasing and functionally sound. The cabinet is designed to
fit between studs for semi-flush mounting. This compact
design and the key-activated dead-front construction
enables secure routine maintenance of the system. Access
to system function keys is limited by a key switch. Multiple
levels of password protection prohibit unauthorized use.
The circuit boards are mounted on a removable chassis,
and are designed with pluggable terminal strips for ease of
installation and service.
Operator’s Display
The IF602SS’s operator’s display controls all user access
to the system. The display provides all of the necessary
keys and annunciation points to maintain and monitor the
system. Alarm, supervisory, and trouble conditions are all
indicated on the operator’s display by dedicated LEDs and
an internal sounder. The Acknowledge, Reset, and Signal
Silence keys are located directly below the 4 x 40-character backlit alphanumeric display. All system functions and
operational logic can be programmed from the front panel
in the field. The IF602SS display has four user-programmable function keys.
IF602SS
Features
• Listed per ANSI/UL® 864, 9th Edition
• One or two Signaling Line Circuits (SLC), up to 396
points
• Velociti protocol 99 detectors, 99 devices per Loop
• SmartStart™ self-programming logic
• Downloadable or front-panel programmable
• Password protected
• Approved for Supervisory Service
• Fully digital SLC protocol
• SmartLink™ peer-to-peer networkable
• 1000-event history log
• Automatic drift compensation
• Coded signaling capability
• Adjustable sensor sensitivity and temperature settings
• Style 6, 7 (Class A) or Style 4 (Class B) SLC
• Four Style Y (Class B), or two Style Z (Class A)
notification appliance circuits (NACs)
• Semi-flush mounting (between 16" studs)
• 160-character display
• Optional GW-UDACT Compatible
• Built-in strobe and horn synchronization
SmartLink™ and SmartStart™ are trademarks and Velociti® Series is a registered trademark
of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories, Inc.
Microsoft® Windows® is a registered trademark of Microsoft® Corporation.
An ISO 9000-2000 Company
FM
APPROVED
S521
7165-1703:145
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2009 Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
CS-2490 Rev. B page 1 of 3
Analog Addressable Signaling Line Circuits
Remote Display and Control
The IF602SS analog interface module provides Signaling
Line Circuits (SLC), loop circuits that can monitor and control up to 198 analog/addressable devices on each powerlimited loop, for a total of 396 analog points in a dual-loop
system. Loop wiring is polarity sensitive.
Serial annunciator drivers are available in 16-point increments and are an ideal interface to graphic annunciators.
The serial annunciators display system activity and control.
Switches can be used for Acknowledge, Reset, Signal
Silence, Drill, etc., to customize the remote status control
network.
Each SLC loop has a dedicated microprocessor that simultaneously communicates with connected field devices and
the main CPU.
The IF602SS uses Velociti® fully digital communications
protocol to improve the speed and accuracy of event
reporting. The communications protocol provides for alarm
verification per detector, detector adjustability and compensation, adjustable analog heat detector range circuit isolation, and priority interrupts. Priority interrupts allow contacttype devices such as manual fire alarm stations to interrupt
the polling cycle and transmit their addresses at any time
during a polling sequence.
The fully digital protocol allows the IF602SS to operate on
most types of field wiring, greatly expanding its use in retrofit applications. Consult the Supplemental SLC Manual or
Gamewell-FCI Technical Support for specific wiring
requirements.
IF602SS Power Supply
The IF602SS power supply is a fully regulated 8 amp. supply that furnishes system operating and signaling power. It
is equipped with a battery charger which maintains the secondary power source. The power supply is monitored by
the main CPU, ensuring that adequate power levels are
available. The power supply design allows for high efficiency while providing precise power output. The battery
charger maintains batteries up to 26 AH. The supply powers four on-board Notification Appliance Circuits (NACs)
(two Class A) with the multiple built-in synchronization protocols for System Sensor, Cooper-Wheelock and others.
An alphanumeric display can also be used for remote status and control. The alphanumeric display is designed to
communicate over the serial communications network.
The IF602SS can communicate locally or remotely with a
printer to document system activity.
See the RAN/SAN data sheet (CS-2025 and CS-2027) for
complete annunciator details.
Applications
The IF602SS Analog Addressable Control Panel is
designed for new or retrofit small- to mid-sized projects that
require state-of-the-art life-safety systems. The embedded
CPU offers users unrivaled reliability without sacrificing
flexibility or value.
With compatible analog sensors and addressable input and
control interface devices, and its remote status and control
capabilities, the IF602SS provides system engineers with
all the tools necessary to design effective system solutions
for any application.
Architectural/Engineering Specifications
The control panel furnished and installed shall be capable
of supporting 396 addressable devices and two analog
loops. The panel shall use a fully digital Signaling Line Circuit (SLC) protocol. The panel shall contain four on-board
Notification Appliance Circuits (NACs) that support the multiple synchronization protocols. The panel shall use a 160character Liquid Crystal Display (LCD) and a 1,000-event
history log. The panel shall be a Gamewell-FCI IF602SS
with Velociti.
Input (I) / Output (O) Devices
Addressable control output devices are the interface
between analog circuits and building functions. The outputs
are controlled with Control By Event (CBE) software within
the IF602SS, and can be programmed to respond to any
event. The control devices can be used as supervised
remote signaling circuits.
The IF602SS, with Gamewell-FCI’s complete line of 600
Series devices, provides a foundation for system design.
The IF602SS’s RS-232 output expands system monitoring
and control capabilities.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
CS-2490 Rev. B page 2 of 3
www.gamewell-fci.com
Specifications
Ordering Information
Common Control:
Standby Current:
Alarm Current:
Input Power:
0.160A
0.226A plus signaling circuit
power, plus 0.002A for master box,
or plus 0.022A for reverse-polarity
120 VAC, 4.0A; or 240 VAC, 2.0A
Auxiliary Output:
S+/S–, A+/A–:
Common Relays:
2.0 A maximum
1.0A @ 30 VDC, or 0.5A @ 250
VAC
Notification Appliance Circuits:
Circuits:
Output:
Four Class B, two Class A
3.0A maximum@24 VDC per circuit.
Maximum 7.5A total for all circuits
Analog SLC:
198
396
Standby Current:
Alarm Current:
0.035A
0.045A
0.055A
0.055A
Panel Dimensions:
Standard Cabinet:
20.0" H x 14.0" W x 4.5" D
(50.8 H x 35.6 W x 11.4 D cm)
Battery Storage Dimensions:
6.0" H x 9.0" W x 4.5" D
(15.24 H x 22.86 x 11.43 D cm)
Relative Humidity: 93% non-condensing
Temperature
32°F – 120°F (0°C – 49°C)
Rating:
Standard Cabinet:
Model
Description
GWIF602SS-198R IF602SS Analog Addressable System
with Velociti consisting of the following:
• IF602SS common control
• 8 amp. main power supply
• One (1) analog circuit module
(198 analog addressable points)
• Standard cabinet assembly
(CAB-602R)
Standard Cabinet:
20.0” H x 14.0” W x 4.5” D
(50.8 H x 35.6 W x 11.4 D cm)
GWIF602SS-396R IF602SS analog addressable system
with Velociti, consisting of the following:
• IF602SS common control
• 8 amp main power supply
• Two (2) analog circuits module
(396 analog addressable points)
• Standard cabinet assembly
(CAB-602R)
Standard Cabinet:
20.0” H x 14.0” W x 4.5” D
(50.8 H x 35.56 W x 11.43 D cm)
52358
IdentiFlex 602SS Analog/Addressable
Fire Alarm Control Panel Installation
and Operation Manual
GW31077
CTM-602, city-tie/remote signaling
module for 602 Series panels.
GW31078
ISO-232, RS-232 serial-port isolator
module for 602 Series panels.
GW31079
CLA-602, Class “A” adapter module for
SLC, 602 Series panels.
GW70703
Coiled Programming Cable
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
www.gamewell-fci.com
CS-2490 Rev. B page 3 of 3