Type VMN Voltge Monitoring Resistor Networks

Type VMN Voltage Monitoring Resistor Networks
Transient Tolerant
New
Voltage Dividers for Industrial Power Quality and Power Consumption Metering Applications
Ratio Tolerance of 0.1% or 0.02%, Ratio TC of 10 ppm/°C or 5 ppm/°C
The Type VMN Transient Tolerant Voltage Monitoring Networks are designed
for use in the voltage measurement circuits of Power Quality Monitoring
Equipment, Kilowatt-Hour Meters, and other Power and Energy Measurement
Equipment, where precision electrical service voltage monitoring is required.
The VMN Networks are manufactured with Tetrinox®, Caddock’s Ultra-Stable
Low-TC Resistance Film System. The Tetrinox film system, combined with
Caddock’s Ceramic Sandwich Resistor Network construction, provides
outstanding long-term stability in industrial applications with electrical surges,
transient conditions, and high humidity exposure.
For Custom Type VMN Voltage Monitoring Networks developed to meet your
program requirements, contact Applications Engineering at Caddock.
7
8
1
2
Resistance
Normal
Operating
Voltage
(AC rms)
Maximum
Operating
Voltage
(AC rms)
Voltage
Divider
Ratio
R1
R2
Total
Resistance
(R1 + R2)
VMN4-2M-400
450 Volts
600 Volts
400 : 1
1.995 Meg
5K
VMN4-2M-400-5
450 Volts
600 Volts
400 : 1
1.995 Meg
5K
VMN4-5M-500
700 Volts
900 Volts
500 : 1
4.990 Meg
VMN4-5M-500-5
700 Volts
900 Volts
500 : 1
4.990 Meg
Part Number
5
4
3
6
Ratio
Tol.
Ratio
T.C.
Ratio
V.C.
Overload
Voltage
Rating
Impulse
(Surge)
Voltage
2 Meg
0.1%
10 ppm/°C
0.03 ppm/V
1,000 Volts
10 kV
2 Meg
0.02%
5 ppm/°C
0.03 ppm/V
1,000 Volts
10 kV
10 K
5 Meg
0.1%
10 ppm/°C
0.02 ppm/V
1,500 Volts
10 kV
10 K
5 Meg
0.02%
5 ppm/°C
0.02 ppm/V
1,500 Volts
10 kV
Specifications
1
Ratio: (R1+R2) : R2 (Voltage Divider Ratio)
2
Ratio Tolerance: measured at 100 Volts at +23°C ambient
3
Ratio T.C.: measured at -40°C and +85°C, ref. to +25°C
4
Ratio V.C.: measured at 100 Volts DC and 600 Volts DC
1.000 ±.020
(25.40 ±.51)
Absolute T.C.: 30 ppm/°C, measured at -40°C and +85°C,
referenced to +25°C
Ratio Stability:
7
Normal Operating Voltage applied to R1 and R2 connected
in series at +85°C. Change in Ratio after 2,000 hours is
±0.02% maximum.
8
Maximum Operating Voltage applied to R1 and R2
connected in series at +85°C. Change in Ratio after 2,000 hrs
is ±0.04% maximum.
5
Overload Voltage and Stability: Overload Voltage applied
for 10 seconds to R1 and R2 connected in series at +25°C.
Change in Ratio is 0.01% maximum.
6
Impulse Voltage and Stability:
1.2/50 microsecond
waveform. The impulse voltage wave shape shall have a
rise time of 1.2 microseconds to 90% of the impulse voltage
peak, followed by a fall time of 50 microseconds to 50% of the
impulse voltage peak. Impulse applied to Pin 1 (with R1 and
R2 connected in series), with Pin 5 held near ground. After
20 pulses applied, the Change in Ratio is 0.01% maximum.
.510 ±.020
(12.95 ±.51)
Seated Height
CADDOCK
VMN4-5M-500-5
1432
Absolute Tolerance: ±1%
.110 Max.
(2.79)
6
D
.050 (1.27)
.100 (2.54)
.600 (15.24)
.700 (17.78)
.020 ±.002
(0.51 ±.05)
.900 (22.86)
R1
1 2
See Lead Form
Detail Note
Lead Form Detail Note:
The lead form detail provides
interference in the circuit board
hole to achieve a vertical mount
of the device. Recommended
circuit board hole is nominally
0.039 inch (1.00 mm).
R2
3 4
.150 ±.040
(3.81 ±1.02)
5
Isolation Dimension D:
Minimum distance between
metal portions of Pins 2 and 3
is 0.414 inch (10.51 mm)
Operating Temperature Range: -40°C to +85°C
Applications Engineering and Sales
17271 North Umpqua Hwy.
Roseburg, Oregon 97470-9422
Phone: (541) 496-0700
Fax: (541) 496-0408
© 2014 Caddock Electronics, Inc.
e-mail: [email protected] • web: www.caddock.com
For Caddock Distributors listed by country see caddock.com/contact/dist.html
Corporate Office
1717 Chicago Avenue
Riverside, California 92507-2364
Phone: (951) 788-1700
Fax: (951) 369-1151
IL-428.1014