Super Vu-Tron® Diesel Locomotive Cable(1)

Cord
Industrial Cord
Super Vu-Tron® Diesel Locomotive Cable(1)
90ºC 2000 Volt DLO, UL RHH/RHW 600 Volts CSA R90 1000 Volt
Product Construction:
Conductor:
• 10 AWG through 777.7 MCM stranded
tinned annealed bare copper per
AAR 589
Insulation:
• Premium grade 90ºC EPDM
Jacket:
DLO – 2000 VOLTS – EP/CPE
CATALOG
NUMBER
AWG
SIZE
COND.
STRAND
INCHES
mm
INCHES
mm
(2)
(4)
81910
81908
81906
81904
81902
81901
81911
81920
81930
81940
81926
81931
81937
81944
81953
81964
81977
10
8
6
4
2
1
1/0
2/0
3/0
4/0
262.6
313.3
373.7
444.4
535.3
646.4
777.7
27/24
37/24
61/24
105/24
154/24
224/24
280/24
329/24
456/24
551/24
650/24
777/24
925/24
1110/24
1332/24
1600/24
1924/24
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.120
0.120
0.110
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
3.05
3.05
2.79
0.26
0.33
0.41
0.46
0.52
0.65
0.69
0.73
0.81
0.87
1.00
1.06
1.10
1.23
1.34
1.45
1.50
6.60
8.38
10.41
11.68
13.21
16.51
17.53
18.54
20.57
22.10
25.40
26.92
27.94
31.24
34.04
36.83
38.10
40
55
75
95
130
150
170
195
225
260
296
326
362
400
445
493
910
55
80
105
140
190
220
260
300
350
405
467
522
591
652
728
815
904
60
95
145
205
295
440
515
580
770
930
1130
1295
1545
1820
2195
2560
3050
(3)
(3)
(2)
(3)
(4)
(S)
CURRENT
AMPS
APPROX.
NET WEIGHT
LBS/M'(S)
(3)
(1)
NOM. INS.
THICKNESS
NOMINAL. O.D.
All products indent printed P-7K-123040 MSHA to indicate compliance with MSHA Flame Test Standards.
Ampacities based on 90ºC Conductor and 30ºC Ambient temperature based on Table 310-16 in the National Electrical Code®
for RHH/RHW with not more than 3 current carrying conductors in raceway, cable or earth.
(UL) RHH/RHW 2000 Volts
Ampacities based on single conductor in free air, in accordance with NEC Table 310-17.
Actual shipping weight may vary.
• Chlorinated polyethylene (CPE), Black
Jacket Marking:
• SIZES 10 THROUGH 1 - CAROL SUPER
VU-TRON (SIZE) (STRANDING) 90C DLO
2000 VOLTS P-7K-123040 MSHA CSA
R90 1000V (UL) RHH OR RHW 600
VOLTS
• SIZES 1/0 THROUGH 646.4 - CAROL
SUPER VU-TRON (SIZE) 90C DLO
2000 VOLTS P-7K-123040 MSHA CSA
R90 1000V (-40C) FT-1 – (UL) RHH OR
RHW 600 VOLTS SUNLIGHT RESISTANT
FOR CT USE
• SIZE 777 MCM ONLY - CAROL SUPER
VU-TRON E194120 C(UL) TYPE RHW-2
2KV VW-1 FOR CT USE TYPE DLO
2000V 90C P-102099 MSHA
NOTE: (535.3 AND 646.4 MCM MARKED
(UL) RHH OR RHW 2000 VOLTS)
Applications:
•
•
•
•
•
•
•
Diesel electric locomotives
Telecom power supply
Oil and gas drilling rigs
Mining and earth moving equipment
Shipyards
Motor leads
Where flexible power leads must be
installed in conduit or raceways
Features:
•
•
•
•
90ºC temperature rating
Excellent impact and abrasion resistance
Resists oils, acids, alkalies, heat, flame
Flexible tinned copper stranding
Industry Approvals:
• UL Listed
• MSHA Approved
• CSA R90
Packaging:
• Lengths cut to order
®
31