Super Vu-Tron® Single Conductor

Industrial Cord
Cord
Super Vu-Tron® Single Conductor
90ºC (UL) Type W 2000 Volt and Type RHH/RHW 600 Volt Portable Power Cable
Product Construction:
Conductor:
• 8 through 500 MCM fully annealed
stranded bare copper
Insulation:
• Premium grade 90ºC EPDM
Cable Reinforcement:
TYPE W 2000 VOLT (UL) AND TYPE RHH/RHW 600 VOLT (UL)
(1)
(2)
(S)
NOM. INS.
THICKNESS
NOMINAL. O.D.
CURRENT
AMPS
CATALOG
NUMBER
NO. OF
COND.
AWG
SIZE
COND.
STRAND
INCHES
mm
INCHES
mm
(1)
(2)
83008
83006
83004
83002
83001
83010
83020
83030
83040
83250
83350
83500
1
1
1
1
1
1
1
1
1
1
1
1
8
6
4
2
1
1/0
2/0
3/0
4/0
250
350
500
133
259
259
259
259
259
259
259
259
627
855
1235
0.070
0.070
0.070
0.070
0.090
0.090
0.090
0.090
0.090
0.105
0.105
0.105
1.78
1.78
1.78
1.78
2.29
2.29
2.29
2.29
2.29
2.67
2.67
2.67
0.485
0.565
0.605
0.680
0.765
0.810
0.885
0.930
0.980
1.045
1.145
1.310
12.32
14.35
15.37
17.27
19.43
20.57
22.48
23.62
24.89
26.54
29.08
33.27
55
75
95
130
150
170
195
225
260
290
350
430
80
105
140
190
220
260
300
350
405
455
570
700
APPROX.
NET WT.
LBS/M'(S)
160
220
290
395
490
575
700
820
1000
1170
1520
2090
Ampacities based on 90ºC Conductor and 30ºC Ambient temperature based on Table 310-16 in the National Electrical Code®
for RHH/RHW with not more than 3 current carrying conductors in raceway, cable or earth.
Ampacities based on 90ºC Conductor and 30ºC Ambient temperature based on Table 310-17 and Table 400.5(B) in the
National Electrical Code® for single conductor cables.
Actual shipping weight may vary.
• An open polyester braid reinforcement is
applied between the insulation and jacket
for mechanical strength.
Jacket:
• Super Vu-Tron® 90ºC, Black
• Temperature Range: -40ºC to +90ºC
• Voltage rating:
600 Volt Type RHH/RHW
2000 Volt Type W
Jacket Marking:
• #8 - #1 AWG — CAROL SUPER VUTRON TYPE W PORTABLE POWER
CABLE (UL) DRY 90C WET 75C 2000V
SUNLIGHT RESISTANT P-7K-123049MSHA (SIZE) TYPE RHH OR RHW (UL)
600V
• #1/0 - 500MCM — CAROL SUPER VUTRON TYPE W PORTABLE POWER
CABLE (UL) DRY 90C WET 75C 2000V
SUNLIGHT RESISTANT P-7K-123049MSHA (SIZE) TYPE RHH OR RHW (UL)
600V FOR CT USE---CSA TYPE W
(-40C) FT-5
Applications:
• Portable power systems
• Entertainment industry activities such as
theatre, television, night clubs, motion
pictures, mobile communication vans,
spotlights and sound systems
• Other similar applications that would
require permanent or temporary power
• Permanent wiring of 600 Volt power
supplies, hoists, cranes and other
applications where flexible power leads
must be installed in conduit or raceways
Features:
• Water resistant
• Sunlight resistant
• Designed to withstand severe
environmental conditions
• Withstands exposure to oil, acids,
alkalies, heat, flame, moisture and
chemicals
• Meets or exceeds flame test
requirements of MSHA, ICEA
and UL
Industry Approvals:
•
•
•
•
ICEA S-75-381 NEMA WC-58
UL Type W
UL Type RHH or RHW
MSHA Approved
Packaging:
• Lengths cut to order
®
23