Filled Foam Skin CACSP Cable Spec. 2007

Filled Core Cables
Outside Voice & Data
Filled Foam Skin CACSP Cable
Spec. 2007
RUS (REA) PE-89 CACSP
Core Construction:
Conductors:
• Solid, annealed copper; sizes 22 and
24 AWG
Insulation:
Nominal Cable Data
CATALOG
NUMBER
PAIRS
AWG
O.D.
INCHES
WEIGHT
LBS/MFT
STANDARD
LENGTH (FT)
7526551
7526569
7526577
7526585
7526593
7526601
7071574
7526619
7526627
7526635
7526643
7526650
7071608
7526668
7526684
7526692
7526700
7526718
7526726
7526734
7526742
7526759
7526767
7526775
7071616
7071624
7071632
6/22
12/22
25/22
50/22
75/22
100/22
150/22
200/22
300/22
400/22
600/22
900/22
6/24
12/24
25/24
50/24
75/24
100/24
150/24
200/24
300/24
400/24
600/24
900/24
1200/24
1500/24
1800/24
0.47
0.54
0.65
0.83
0.97
1.1
1.3
1.4
1.7
2.0
2.4
2.9
0.40
0.46
0.60
0.72
0.81
0.90
1.1
1.2
1.4
1.6
1.9
2.3
2.6
2.9
3.2
125
180
280
465
635
790
1140
1430
2050
2695
4070
5930
90
125
210
330
430
550
750
980
1370
1800
2590
3790
4920
6110
7280
5000
5000
5000
5000
5000
2500
2500
2500
1250
1250
1250
1000
5000
5000
5000
5000
5000
5000
5000
2500
2500
2500
1250
1250
1000
1000
1000
Data subject to change without notice. Contact your Customer Service Representative for latest information.
• Dual insulation consisting of an inner layer
of foamed polyolefin surrounded by a solid
polyolefin skin, color coded in accordance
with telephone industry standards
Twisted Pairs:
• Insulated conductors are twisted into pairs
with varying lay lengths to minimize
crosstalk
Core Assembly:
• 25 pairs and less: pairs are assembled
together in a single group
• More than 25 pairs: pairs are arranged in
groups, each group having a color coded
unit binder
Filling Compound:
• The entire core assembly is completely
filled with ETPR compound, filling the
interstices between the pairs and under
the core tape
Core Wrap:
• Non-hygroscopic dielectric tape applied
longitudinally with an overlap
CACSP Sheath:
Aluminum Shield:
• Corrugated, copolymer coated, 0.008"
aluminum tape applied longitudinally over
the core wrap
Steel Shield:
• Corrugated, copolymer coated, 0.006"
steel tape applied longitudinally over the
aluminum tape with an overlap
• The sheath interfaces are flooded with an
adhesive water blocking compound
Jacket:
• Black, linear low density polyethylene
Application(s):
• Intended for duct and direct buried
installations where protection against water
and moisture entry is required
• The addition of the steel tape armor
provides increased mechanical protection
and gopher resistance
Compliance:
• Rural Utilities Service (RUS)
7 CFR 1755.890
(REA PE-89)
Packaging:
• Standard lengths are shipped on
non-returnable wood reels
• Non-standard packaging is available upon
request
17