F200/400 FAMILY Intronics, Inc.

Intronics, Inc.
F200/400 FAMILY
HIGH DENSITY DC/DC CONVERTERS
F Series
200/400W Full Bricks
Description
The F series of high current DC/DC converters offer
current levels that are comparable to existing full-bricks.
With a wide input voltage range of 36-75V or 18~36V, they
are available with an output voltage of either 2.5, 3.3, 5 or 12
Volts. All models feature an input filter, input undervoltage
lockout, output overvoltage and overtemperature protection,
output current limiting and short circuit protection. The
unique construction with aluminum heat spreader design
achieves efficient heat transfer with no hot spots. The use of
patented Flat Matrix Transformer technology and other
patent-pending design concepts facilitate maximum power
delivered. The converters combine creative design concepts
with highly derated power devices to achieve very high
reliability, high performance and offer a low cost solution to
systems designers that are challenged to maximize power
and minimize board space.
Features
•
•
•
•
•
•
•
Delivers up to 200/400w in Bull Brick
High efficiency patented topology
Low profile of only 0.50 inch
2.5V, 3.3V, 5V ,12V or 24V output modules
-40°C to +85 °C ambient operation
Meets Basic Insulation requirements of EN60950
UL 1950 recognized, TUV EN60950, and CSA C22.2
No. 950 Certified and CE marked
• Meets conducted limits of FCC Class B and CEI
IEC61204-3 Class B with external filter
Applications
•
•
•
•
•
•
•
Telecommunications
Data Communications
Wireless Communications
Networking Gear
Servers, Switches and Data Storage
Semiconductor Test Equipment
Distributed Power Architecture
Approvals Pending
Specification Summary
• 100A @ 2.5V, 50A @ 3.3V, 80 @ 5V, 34A @ 12V and more
• Tight output regulation, typical ±1%
• No minimum load required
• Ripple & Noise ( 20Mhz BW) 100 mv (pk-pk) typical
• Wide input operating range 36-75V, 18-36, or 200-400V
• On/Off pin and remote sense
• Output adjustment +/-10% range
• Remote sense compensation
• 1500V, 10M
input-to-output isolation
• Output overcurrent and overvoltage protection
• Over Temperature protection
• Input Under voltage protection
• MTBF of 1,500,000 hours @ 50°C ( Bellcore )
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev. B 7/8/03
F 200/400 FAMILY
200/400W
Full Bricks
Intronics, Inc.
Product Brief
Part Number and Selection Information
Input
Model
Voltage (Volts)
Part Number
Nominal
Output
Current (A)
No load
F200-48S3.3
48
0.2
F200-48S5
48
0.2
F200-48S12
48
0.2
F200-24S3.3
24
0.2
F200-24S5
24
0.2
F400-24S12
24
0.2
F200-300S3.3
300
0.2
F200-300S5
300
0.2
F200-300S12
300
0.2
F200-300S15
300
0.2
F400-48S3.3
48
0.2
F400-48S5
48
0.2
F400-48S12
48
0.2
F400-48S15
48
0.2
F400-48S24
48
0.2
F400-300S3.3
300
0.2
F400-300S5
300
0.2
F400-300S12
300
0.2
F400-300S15
300
0.2
F400-300S24
300
0.2
Consult factory for other output voltage configurations
Efficiency
Voltage
Current
75% Load
Full load
(Volts)
(Amps)
(%)
4.5
5.4
5.4
7.2
8.0
10.8
0.7
0.9
0.9
0.6
12
11
10.9
10.7
10.6
1.8
1.7
1.7
1.7
1.6
3.3
5.0
12.0
3.3
5.0
12.0
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
24.0
3.3
5.0
12.0
15.0
24.0
50
40
17
40
30
34
40
40
17
10
100
80
34
27
17
100
80
34
27
17
77
78
79
77
78
79
77
78
79
80
77
78
79
80
81
77
78
79
80
81
Outline Information and Pin-out
Pin Connection
F200
Pin # Function Pin Size
F400
Pin Size
1
Vin +
0.04"
0.08"
2
On/Off
0.04"
0.08"
3
NC
0.04"
0.08"
4
Vin -
0.04"
0.08"
5
Vout-
0.08"
0.18"
6
-Sense
0.04"
0.08"
7
Trim
0.04"
0.08"
8
+Sense
0.04"
0.08"
9
Vout +
0.08"
0.18"
All dimensions are in inches [mm]
0.04”[ 1.016mm]; 0.08” [2.032mm]
0.18” [4.572mm]
Pin material: Brass
Pin finish: Tin/Lead plated
Heat spreader (baseplate) material:
Aluminum.
Weight: 135g
The information and specifications contained in this brief are believed to be accurate and reliable at the time of publication. Specifications are
subject to change without notice. Refer to product specification sheet for performance characteristics and application guidelines.
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03
F 200/400 FAMILY
200/400W
F400-48 Series
Full Bricks
Intronics, Inc.
48Vin 3.3, 5, 12, 15, 24Vout 400W
Product Brief
Electrical Specification
Typical test data at Ta=25°C, Vin=48V unless otherwise noted.
PARAMETER
NOTES
Absolute maximum rating
Input voltage
Operating case temperature
Storage temperature
Humidity
MIN
TYP
0
-25
-40
MAX
UNIT
80
100
125
95
V
°C
°C
%
Input characteristics
Operating input voltage range
36
Turn on voltage threshold
Turn off voltage threshold
Off converter input current
75
V
33.5
34
34.5
V
33
33.5
34
36Vin
8
V
mA
Output characteristics
Output voltage
F400-48S3.3
36-75Vin, no load to full load
3.25
3.30
3.35
V
F400-48S5
36-75Vin, no load to full load
4.85
5.00
5.15
V
F400-48S12
36-75Vin, no load to full load
11.7
12.0
12.3
V
F400-48S15
36-75Vin, no load to full load
14.3
15.0
15.7
V
F400-48S24
36-75Vin, no load to full load
22.8
24.0
25.2
V
Output current
F400-48S3.3
0
100
A
F400-48S5
0
80
A
F400-48S12
0
40
A
F400-48S15
0
30
A
F400-48S24
0
20
A
Output voltage trim range
Percentage of normal output
Output voltage ripple and noise
20Mz bandwidth, 100% Load, 48Vin,
Output over power protection
Over-voltage protection
Over-temperature protection
Temperature coefficient
Output dynamic characteristics
Startup time
Transient recovery time
Transient Peak
Efficiency
F400-48S3.3
F400-48S5
F400-48S12
-10
110
+10
%
1
2
% Vnom
125
140
%
125
105
150
110
±0.05
%
°C
%/°C
20
ms
800
400
µs
mv
5% to 95% of the output voltage
25% load change (2.0A/us)
25% load change (2.0A/us)
75
77
78
79
F400-48S15
%
%
%
%
80
%
Isolation voltage(primary to secondary) 1minute
1500
VDC
Isolation voltage (primary to case)
1minute
1000
VDC
Isolation voltage (secondary to case)
1minute
1000
VDC
Isolation resistance
500VDC, Primary to secondary
F400-48S24
Isolation characteristics
10
MΩ
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03
F 200/400 FAMILY
F400-48 Series
200/400W Full Bricks
48Vin 3.3, 5, 12, 15, 24Vout 400W
Intronics, Inc.
Product Brief
Basic operation and functions
The F400 family uses planar transformer
technology to achieve high output current. The
whole unit switches at the fixed frequency for a
predictable EMI performance. The F400 Brick
has many standard controls and protection
functions.
Input Power ( pin1, pin4 )
Input power Vin(+) must be connected to Positive
input voltage pin1; Input power Vin(-) must be
connected to Negative input voltage pin4.
Output Power ( pin9, pin5 )
Output power Vout(+) must be connected to
Positive output voltage pin9; Output power
Vout(-) must be connected to Negative output
voltage pin5.
Pin 2 is the "Enable" pin, connecting a TTL
compatible pin. A TTL control signal to this pin,
according to the specification, will turn the unit on
or off.
The positive logic version turns on when pin 2 is
at logic high, and turns off when pin 2 is at logic
low. The unit is on when pin 2 is left open.
Remote Sense ( pin 8, pin 6 )
Permits the user to maintain the accurate output
voltage at the remote load terminals regardless of
the line drop.
The Sense(-) (pin6) and Sense(+) (pin8) should
be connected at the load or at the point where the
regulation is needed. ( shown on Fig. 2)
On/Off ( pin 2 )
Permits the user to maintain unit On/Off, in order
to properly sequence different power supplies
and reduce power consumption during the
standby condition. There is the remote control
available, positive logic is referenced to Vin(-),
and typical connections are shown in Fig 1.
Fig 2: Remote Sense Circuit
The remote sense feature of the unit
compensates for voltage drop occurring between
the output pins of the unit and load. The Sense(-)
(pin5) and Sense(+)(pin7) should be connected at
the load or at the point where regulation is
required.
Fig. 1: Typical Circuit for On/Off Function
If remote Sense is not required, the Sense(-) pin
must be connected to the Vout(-) pin (pin5), and
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03
F 200/400 FAMILY
F400-48 Series
200/400W Full Bricks
48Vin 3.3, 5, 12, 15, 24Vout 400W
the Sense(+) pin must be connected to the
Vout(+) pin(pin 9) to ensure the unit will regulate
at the specified output voltage. If these
connections are not made, the unit’s output
voltage will be higher than the specified value.
Intronics, Inc.
Product Brief
When trimming up, care must be taken, not to
exceed the unit OVP threshold. A typical circuit is
shown in Fig. 3.
The unit output over voltage protection senses
the voltage across Vout(+) and Vout(-), and not
across the sense lines, so the resistance between
the output pins of the unit and the load should be
minimized to prevent unwanted triggering of the
OVP.
When using the remote sense feature, the output
voltage at the unit can be increased by as much
as 10% above the normal rating, in order to
maintain the required voltage across the load.
Therefore, the designer must consider this
condition.
Also when using the remote sense function, the
output power must be taken care of, as not to
exceed the maximum power capability of the unit.
Fig 3. Trim Up Output Voltage Circuit
Trimming down the output voltage for a typical
circuit, as shown on Fig. 4.
Output Voltage Trim (pin 7)
Permits the user to adjust the output voltage up
or down to achieve the custom voltage or to make
the output voltage margining. The adjustment
range is from + 10% to -10%.
Output voltage can be adjusted up or down, by
connecting the Rtrim-up or Rtrim-down resistor as
shown. Rtrim-up makes the output voltage go up
to 10%; and the Rtrim-down makes the output
voltage go down to 10%.
Fig 4. Trim Down Output Voltage Circuit
Leave Trim pin ( Pin 7) open for normal output
voltage.
Intronics, Inc. - 1400 Providence Highway, Building2 2, Norwood, MA 02602
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03
F 200/400 FAMILY
F400-48 Series
Intronics, Inc.
200/400W Full Bricks
48Vin 3.3, 5, 12, 15, 24Vout 400W
Product Brief
Protection Features
Input Under-voltage lockout ( IUV )
Input under voltage ( IUV ) is standard with the
F400 unit. The unit will shut down when the
input voltage drops below a threshold, and the
unit will turn on when the input voltage goes to
the upper threshold.
The hysteretic voltage of the under voltage
protection is 1V, normally from the 34V to 35V
range.
Output Over-current Protection ( OCP )
Over Temperature Protection ( OTP )
The unit will shut down when the base plate
temperature exceeds the protection threshold.
The unit will shut down under the base plate
temperature over a 105°C condition to protect the
unit from overheating. The OTP circuit will turn
the unit off when OTP happens. Once the unit
has shut down, it will restart at the cycle when the
base plate temperature goes down.
Typical Derating Specificatins (F400-48S3.3)
(Heatsink information is on the following page)
70
The unit will shut down when the over current or
short circuit condition exists.
60
W / O HS
W / HS
until the over current or short circuit condition is
removed. When OCP happens, the output
voltage drops below 1.1V.
Output Current (A)
Once the OCP happens, the unit has shut down.
The attempted restart will continue indefinitely
50
40
30
20
10
Input voltage has almost no effect on the current
limit point.
0
0
20
40
60
80
100
Ambient Temp. (deg.C)
The unit will shut down when the output voltage
exceeds the over voltage threshold.
If the output voltage across Vout(+) (pin9) and
Vout(-) (pin5) exceeds the threshold of the OVP
circuitry, the unit has shut down which is caused
by an OVP circuit, and the unit will never restart,
and the output voltage is below 1V.
Fig 1. F400-48S3.3 Brick Temp. De-rating curves with and without Heatsink.
120
Output Current (A)
Output Over-voltage Protection ( OVP )
100LFM
200LFM
300LFM
400LFM
100
80
60
40
20
0
0
20
40
60
80
100
Ambient Temp. (deg. C)
Fig 2. F400-48S3.3 Brick Temp. De-rating curves with Heatsink at air forced condition.
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03
F 200/400 FAMILY
F400-48 Series
200/400W Full Bricks
48Vin 3.3, 5, 12, 15, 24Vout 400W
Intronics, Inc.
Product Brief
Application information
Input Source Impedance
The unit has been designed to be stable with no
external capacitors when used in a low
inductance input and output circuit.
However in many applications, the inductance
with the distribution from the power source to the
input of the unit can affect the stability of the unit.
The addition of 470uF electrolytic capacitor with
an Esr < 1Ω (at 100khz) across the input can
ensure the stability of the unit. Also in many
applications, the user has to use decoupling
capacitors at the output load, to ensure the hold
up time for the load.
Safety Requirements and Considerations
If the input source is non-SELV ( ELV or a
hazardous voltage greater than 60 Vdc and less
than or equal to 75 Vdc), for the unit output to be
considered meeting the requirements of safety
extra low voltage (SELV), all of the following must
be met:
•
The input source is to be provided with
reinforced insulation from any hazardous
voltage, including the ac main.
•
The input pins of the unit are not operator
accessible.
•
For whole system, for safety agencies
requirements, and for the combination of
the unit’s input side (primary side) and the
unit’s output side (secondary side), verify
that under a single fault, hazardous
voltages do not appear at the unit’s output
side (secondary side).
Never ground either of the input pins of
the unit without grounding one of the
output pins. This may allow a non-SELV
voltage to appear between the output pin
and ground.
The unit meets the American and International
safety regulatory requirement UL1950. Basic
insulation is also provided between the input side
and the output side.
To meet safety agencies requirements, an input
line fuse must be used external to the unit. An
25A fuse or less with a normal blow rate must be
used to meet the safety agencies requirements. A
minimum 42LFM airflow should also be provided
if the unit is intended to operate at full power
without heatsink.
•
Heatsink Specifications
(See previous page for derating information)
Heatsink Material:
Heatsink Dimensions:
Aluminum Extrusion
2.44” x 4.60; x 0.78
Thermal Impedance = 3.0 ºC / W
The converter can be operated at full load with
appropriate forced air cooling or by using a lower resistance Heatsink.
Intronics, Inc. - 1400 Providence Highway, Building 2, Norwood, MA 02062
Tel.: 781-551-5500 • Fax: 781-551-5555 • www.intronics.com • Email: [email protected] F400 Rev1 1/31/03