Model CIP - Honeywell Test and Measurement Sensors

Model CIP
Ultra Sanitary Process Transmitter
These CIP (Clean-In-Place) sanitary process transmitters are
meet the environmental demands found in the applications listed
manufactured in stainless steel and offer a variety of flanges,
below in potential applications.
electrical connections, and operating temperatures designed to
FEATURES
•
10 psig/a to 600 psig/a range
•
Track temperature changes, 93 °C/minute [200 °F/minute]
•
4 mA to 20 mA output
•
500 ms pressure response time
•
Secondary containment exceeds 1500 psi
•
Accuracy to 0.1 %
•
Intrinsically safe available (2N option only)9
•
CE approved10
A
3
Complies to
standard
Model CIP
PERFORMANCE SPECIFICATIONS
RANGE CODES
Characteristic
Measure
Range Code
Available ranges
Pressure ranges
38,1 mm [1.5 in] flange, 10 psi to 600
psi; 51 mm [2 in] flange, 10 psi to 500
psi; 63,5 mm [2.5 in] flange, 10 psi to
400 psi; 76 mm [3 in] flange, 10 psi to
250 psi
AV
10 psi
BJ
15 psi
BL
25 psi
600 psi with 13MHHS clamp at 22 °C
[72 °F], 38,1 mm [1.5 in]
BN
50 psi
Max. flange pressure
BR
100 psi
Response time
(comb. mech. & elect.)
500 ms
CL
200 psi
CN
250 psi
Resolution
Infinite
CQ
400 psi
Orientation sensitivity
0.03 psi/G
CR
500 psi
CS
600 psi
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Process temperature
-29 °C to 127 °C [-20 °F to 260 °F]
Sensor temperature4
-1 °C to 82 °C [30 °F to 180 °F]
Temperature effect, zero5
1 % full scale/38 °C [100 °F] (2 % full
scale/38 °C [100 °F] for 1 psi)
Temperature effect, span5
1 % full scale/38 °C [100 °F] (2 % full
scale/38 °C [100 °F] for 1 psi)
2,3
ELECTRICAL SPECIFICATIONS
OPTION CODES
Range Code
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Pressure ranges
10, 15, 25, 50, 100, 200, 250, 400, 500, 600 psi
Temperature
compensation
-1 °C to 82 °C [30 °F to 180 °F]
1i. -54 °C to 121 °C [-65 °F to 250 °F]
Internal
amplifiers
2n(2N).Intrinsically safe amp 4 mA to 20 mA,
two-wire current
Characteristic
Measure
Supply voltage
13 Vdc to 32 Vdc
Internal amplifier
Special filtering
enhancements
Electrical connection (std)
1/2-14 NPT conduit exit with 1,5 m [5 ft]
cable
Pressure ports
Tri-clover
Load impedance (max.)
950 ohm @ 32 Vdc
Zero balance
4 mA ± 0.16 mA
Output (std)
4 mA to 20 mA, two-wire
Electrical
termination
6j. 1/2-14 NPT conduit fitting with 1,5 m [5 ft] of
four conductor PVC cable
6a. Bendix PTIH-10-6P or equivalent 6 pin
6m. DIN 436508
6n. DIN 40050
Shunt
calibration
3d. Remote buffered shunt calibration
Special
calibration
Compound, vacuum, barometric
Bar
Wetted
diaphragm
10c. Hastelloy C-276
Bridge
resistance
12b. 5000 ohm (foil) (max. 121 °C [250 °F])
Zero and span
adjustments
14b. Top access to pots
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
Steam, ethylene oxide, liquid, gas
Wetted parts material
316-L stainless, Hastelloy C-276
Fill material
NEOBEE M-20
Weight (nominal)
454 g [16 oz]
Case material
316-L stainless
Sanitary standard
3-A, #74-03
Over pressure
4X to max. flange pressure
2 Honeywell • Sensing and Control
Ultra Sanitary Process Transmitter
INTERNAL AMPLIFIERS
Mounting dimensions and characteristics
Amplifier
specifications
Intrinsically safe amp:
Option 2n(2N)***
Output signal
4 mA to 20 mA
Input power (voltage)
9 Vdc to 32 Vdc3
Input power (current)
4 mA to 20 mA
Frequency response
2000 Hz
Power supply rejection
60 dB
Operating temperature
-29 °C to 85 °C [-20 °F to 185
°F]
Reverse voltage protection
Yes
Short circuit protection
Yes
Wiring code: connector
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
Wiring code:
cable (std)6,7
R (+) Supply
Bl (+) Output
W Case ground
For reference only
TYPICAL SYSTEM DIAGRAM
*** See Honeywell’s Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.*** See Honeywell’s Web site for the most
up-to-date information regarding Intrinsically safe approvals. Ref #008-0547-00.
WIRING CODES
Cable
Two-wire current, 4 mA to 20 mA
Red
(+) Supply
Black
(+) Output (4 mA to 20 mA)
White
Case ground
Flanges
Code
Size
Flange
16b*
38,1 mm [1.5 in]
Tri-clover
16c
51 mm [2 in]
Tri-clover
16d
63,5 mm [2.5 in]
Tri-clover
16e
76 mm [3 in]
Tri-clover
* Does not comply to 3A standards
Special requirements (consult factory)
Have a special requirement? New case pressure, different cable lengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000 (800-848-6564). Customization is key to our test and
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
Honeywell • Sensing and Control 3
Model CIP
Ultra Sanitary Process Transmitter
NOTES
1.
2.
3.
4.
5.
Accuracies stated are expected for best fit straight line for all errors,
including linearity, hysteresis and non-repeatability.
Higher ranges may be available for special applications. Consult
factory.
Specifications may vary with flange size and pressure range. Consult factory.
-1 °C to 54 °C [30 °F to 130 °F] for 1 psi range (only applicable for
CP100, CP101, CP200, and CP201).
Temperature profile for heated vessels:
Process temperature
Sensor temperature
127 °C [260 °F]
82 °C [180 °F]
93 °C [200 °F]
63 °C [145 °F]
66 °C [150 °F]
49 °C [120 °F]
38 °C [100 °F]
32 °C [90 °F]
24 °C [75 °F]
24 °C [75 °F]
10 °C [50 °F]
18 °C [65 °F]
-18 °C [0 °F]
4 °C [40 °F]
-29 °C [-20 °F]
-1 °C [30 °F]
6.
G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow;
R=Red; O=Orange. Color specifying cable and number or letter
specifying connector.
7. No mating connector necessary with cable option.
8. For zero and span adjustment by instrumentation tech. Electrical
termination is DIN 43650 Hirschmann plug; environmental class
IP65 (NEMA 4). Conduit attachment by PG 9 thread on plug.
9. Range dependent; consult factory.
10. Termination dependent; consult factory.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008697-1-EN IL50 GLO May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.