Designed and Manufactured in Germany Specification Oscillator type: Rev.: 4 Date: 2014-07-08 AXIOM20 OCXO in DIL14 Package with HCMOS Output Parameter min. max. Unit Condition Frequency range Standard frequencies Frequency stability Initial tolerance vs. operating temperature range (steady state) 10 80 10 / 12.8 / 16.384 / 20.000 ±50 ±100 ±200 ±300 ±500 +60 ±10 ±20 ±0.5 MHz MHz ppm ppb ppb ppb ppb ppb ppb °C ppb ppb ppm @ +25°C, VC = 2.5 V Option II =”50” Option II =”100” Option II =”200” Option II =”300” Option II =”500” (Note 2) ±5 3.15 4.75 ppm V V operating temperature range vs. supply voltage variation vs. load change st Long term (aging) 1 year (Note 3) Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Rise & decay time Symmetry Warm-up time Supply voltage VS typ. ±500 -10 ±2 0.15 0.25 1.65 2.5 Positive 100 40 3.3 5.0 Current consumption (steady state) @ +25°C Current consumption (warm-up) Enable/disable function Operable temperature range Storage temperature range Enclosure (see drawing) Weight Packing ESD Sensitivity Handling and Testing Processing Notes: 1. 2. 3. Option I = “33” Option I = “50” kΩ HCMOS 15 3.13 4.75 @ +40°C, after 30 days -30 -40 10 60 2 3.47 5.25 300 200 800 500 pF ns % min V V mA mA mA mA +75 +85 °C °C 20.7x13.1x8.5 max. 5 mm g Palette or tube 1500 V In accordance with AXAN-011 In accordance with AXAN-012 ∆ffinal/f0 < ±0.1 ppm Option I = “33” Option I = “50” Option I = “33” Option I = “50” Option I = “33” Option I = “50” IEC 60679-3 CO 02 HBM, IEC 61000-4-2 www.axtal.com www.axtal.com Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Other operating temperature range on request st Aging of ± 0.2 ppm / 1 year on request GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM20 Rev.4 Drawing D2 Page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Ordering Code: Model (Specification) AXIOM20 Option I 50 Option II 100 Revision Rev.4 Frequency [MHz] 10.000 Enclosure drawing Pin connections Pin # 1 7 8 14 Symbol VC GND RF OUT VS Function Voltage Control (EFC) Ground RF Output Supply Voltage Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 clause ... 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Vibration, sinusoidal* 2-6 4.6.7 Endurance tests - ageing 4.7.1 - extended aging 4.7.2 Other environmental conditions on request Test conditions Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Revision History Rev. Drawing Date [dd.mm.yyyy] 4 4 D1 D2 01.10.2012 08.07.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Editorial changes Editorial changes AXIOM20 Rev.4 Drawing D2 Page 2(2) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]