AXIOM20-33-50_Rev4-25.000MHz

Designed and
Manufactured
in Germany
Specification
Oscillator type:
Rev.: 4
Date: 2014-07-08
AXIOM20
OCXO in DIL14 Package with HCMOS Output
Parameter
min.
max.
Unit
Condition
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. operating temperature range
(steady state)
10
80
10 / 12.8 / 16.384 / 20.000
±50
±100
±200
±300
±500
+60
±10
±20
±0.5
MHz
MHz
ppm
ppb
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppm
@ +25°C, VC = 2.5 V
Option II =”50”
Option II =”100”
Option II =”200”
Option II =”300”
Option II =”500”
(Note 2)
±5
3.15
4.75
ppm
V
V
operating temperature range
vs. supply voltage variation
vs. load change
st
Long term (aging) 1 year (Note 3)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry
Warm-up time
Supply voltage VS
typ.
±500
-10
±2
0.15
0.25
1.65
2.5
Positive
100
40
3.3
5.0
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
Enable/disable function
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
Handling and Testing
Processing
Notes:
1.
2.
3.
Option I = “33”
Option I = “50”
kΩ
HCMOS
15
3.13
4.75
@ +40°C, after 30 days
-30
-40
10
60
2
3.47
5.25
300
200
800
500
pF
ns
%
min
V
V
mA
mA
mA
mA
+75
+85
°C
°C
20.7x13.1x8.5 max.
5
mm
g
Palette or tube
1500
V
In accordance with AXAN-011
In accordance with AXAN-012
∆ffinal/f0 < ±0.1 ppm
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option I = “50”
IEC 60679-3 CO 02
HBM, IEC 61000-4-2
www.axtal.com
www.axtal.com
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Other operating temperature range on request
st
Aging of ± 0.2 ppm / 1 year on request
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM20 Rev.4
Drawing D2
Page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Designed and
Manufactured
in Germany
Ordering Code:
Model (Specification)
AXIOM20
Option I
50
Option II
100
Revision
Rev.4
Frequency [MHz]
10.000
Enclosure drawing
Pin connections
Pin #
1
7
8
14
Symbol
VC
GND
RF OUT
VS
Function
Voltage Control (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60068
Part …
2-17
IEC 60679-1
clause ...
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Vibration, sinusoidal* 2-6
4.6.7
Endurance tests
- ageing
4.7.1
- extended aging
4.7.2
Other environmental conditions on request
Test conditions
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
4
4
D1
D2
01.10.2012
08.07.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Editorial changes
Editorial changes
AXIOM20 Rev.4
Drawing D2
Page 2(2)
Author
Checked
BN
HH
BN
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]