Specification AXLE184B Oscillator type: SMD (VC)TCXO in

Specification
Oscillator type:
Rev.: 2
AXLE184B
SMD (VC)TCXO in gull wing package
Parameter
Frequency range
min.
6
6
1
Frequency stability
vs. operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per year
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Amplitude
Supply voltage VS
Current consumption
(Note 2)
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
typ.
max.
Unit
Condition
190
190
800
MHz
MHz
MHz
ppm
ppm
Clipped Sine wave
Sine wave
HCMOS, PECL, LVDS
Option 4 & 5
ppm
ppm
ppm
VS ±5 %
Load ±10 %
@+40°C
ppm
ppm
V
V
Option 1 = blank
Option 1 = “V”
Option 2 = “3”
Option 2 = “5”
±0.5 to ±5
See tables 1 & 2
±0.1
±0.3
±0.2
±1
±3
±5
0.15
0.5
1.65
2.5
Positive
Date: 2014-04-06
3.15
4.5
100
kΩ
Clipped Sine wave
Sine wave
HCMOS
PECL
LVDS
10 kΩ || 10 pF
50 Ω
15 pF
50 Ω + Bias
0.8
V p-p
1.0
V p-p
0
dBm
+10
dBm
According to relevant Logic Standard
3.15
3.3
3.45
V
4.75
5.0
5.25
V
2 ~ 30
mA
12 ~ 30
mA
15 ~ 50
mA
25 ~ 100
mA
18.6x12.0x7.3 max.
5
Tape & Reel
mm
g
Option 3 = “C”
Option 3 = “S”
Option 3 = “H”
Option 3 = “P”
Option 3 = “L”
Option 3 = “C”
Option 3 = “S”
Option 3 = “H”
Option 3 = “P” or “L”
Option 3 = “C” / 3.3 V
Option 3 = “C” / 5.0 V
Option 3 = “S” / 3.3 V
Option 3 = “S” / 5.0 V
Option 3 = “H”, “P”, “L”
Option 2 = “3”
Option 2 = “5”
Option 3 = “C”
Option 3 = “S”
Option 3 = “H”
Option 3 = “P” or “L”
Pin compatible to CO 02
IEC 60286-3
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Depending on frequency and supply voltage
All combinations of options might not be available. Please consult factory
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXLE184B Rev.2
Drawing D2
Page 1(4)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
6
+105
Unit
Condition
V
V
°C
VS to GND
VC to GND
Frequency stability vs. temperature
Option 4
05
10
15
20
25
30
35
50
Table 1
Stability
[ppm]
±0.5
±1.0
±1.5
±2.0
±2.5
±3.0
±3.5
±5.0
Lower Temperature
Option 5
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
Upper Temperature
Option 5
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Table 2
Ordering Code
Option 2
Option 3
Option 4
[Supply
[RF
[Stability]
Voltage]
output]
AXLE184B
_ or “V”
3 or 5
C, S, H, P, L
Table 1
Example: AXLE184B-V-5-S-10-3D_Rev.2 – 10.000 MHz
Model
Option 1
[EFC]*
Option 5
[Temperature
range]
Table 2
Revision
Frequency [MHz]
Rev.2
10.000
Handling and Testing
Parameter
Procedure
Handling and Testing
Processing
Parameter
Application Note AXAN-011
Application Note AXAN-012
Procedure
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
IEC60749-26
IEC60749-27
Yes
Yes
AXLE184B Rev.2
Drawing D2
Page 2(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections (Without EFC)
Pin #
1
2
3
4
Symbol
Function
N.C. or
No Connection or
Comp OUT Complementary RF Output
(PECL and LVDS)
GND
Ground
RF OUT
RF Output
VS
Supply Voltage
Pin connections (With EFC)
Pin #
1
2
3
4
Symbol
VC
GND
RF OUT
VS
Function
Control Voltage (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXLE184B Rev.2
Drawing D2
Page 3(4)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
2
2
D1
D2
01.10.2012
06.04.2014
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
Editorial changes
Environmental conditions updated, editorial changes
AXLE184B Rev.2
Drawing D2
Page 4(4)
Author
Checked
BN
HH
BN
HH
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]