Designed and Manufactured in Germany Specification Oscillator type: Rev.: 1 Date: 2013-12-10 AXIOM45-23 OCXO High stability, Sine Wave Output Parameter min. Nominal frequency Frequency stability Initial tolerance vs. operating temperature range operating temperature range vs. supply voltage variation vs. load change long term stability (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Output amplitude Warm-up time @25°C Phase noise Short-term stability (ADEV) Reference voltage VREF output Supply voltage VS Current consumption (steady state) Current consumption (warm-up) Operable temperature range Storage temperature range typ. max. Unit ± 10 +60 ±2 ±2 ± 100 MHz ppm ppb ppb °C ppb ppb ppb/year 10.000 ± 500 -10 ± 0.8 0 ±1 VREF Condition @+25°C, VC= VREF/2 steady state VS ± 5% RL ± 10% after 30 days operation ppm V positive 100 kΩ Sine wave 50 Ohm dBm min dBc dBc dBc dBc +3 5 -120 -140 -145 -155 -12 5·10 11.4 10.0 12.0 -30 -40 12.6 100 250 +75 +85 V V mA mA °C °C ∆ffinal/f0 < ±0.1 ppm 10 Hz 100 Hz 1 k Hz 10 kHz τ = 1 sec @ +25°C Enclosure (see drawing) LxWxH 36.1x27.2x16 max. mm IEC 60679-3 CO 08 Weight 30 gram Packing Palette Handling and Testing In accordance with AXAN-011 www.axtal.com Processing In accordance with AXAN-012 www.axtal.com Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIOM45-23 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Rev. Rev.1 Frequency [MHz] 10.000 AXIOM45-23 Drawing D1 www.axtal.com fon: +49 (6261) 939834 page 1(2) fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure: Pin connections Pin # 1 2 3 4 5 Symbol VC VREF VS RF OUT GND Function Control Voltage (EFC) Reference Voltage Supply Voltage RF Output Ground Environmental conditions: Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part ... 2-17 IEC 60679-1 clause ... 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Test conditions Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Endurance tests - ageing - extended aging 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Revision History Rev. Drawing Date [dd.mm.yyyy] 1 1 D0 D1 02.12.2013 10.12.2013 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Author Checked First issue Editorial changes BN HH BN HH AXIOM45-23 Drawing D1 www.axtal.com fon: +49 (6261) 939834 page 2(2) fax: +49 (6261) 939836 E-mail: [email protected]