hitron-e.com

H HiTRON
36-72VDC INPUT RANGE DC-DC CONVERTER HOT-SWAP CompactPCI
QUAD OUTPUT 300 WATTS ACTIVE CURRENT SHARING SWITCHING
POWER SUPPLIES HDC301P-48B SERIES
FEATURES:








300W 3U X 8HP EUROCARD PACKAGE
36-72VDC NOMINAL 48VDC INPUT
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
HOT-SWAPPABLE
THIRD-WIRE CURRENT SHARING
EMI MEET EN 55022 FCC CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 36-72Vdc, nominal input 48Vdc.
Input Connector: Positronic 47-pin PCIH47M400A1.
Inrush Current: Peak 46.2A at nominal 48Vdc.
Input Current: 7.58A at nominal input 48Vdc at full load.
0.16A at nominal input 48Vdc at no-load.
Dielectric Withstand: Meet IEC 60950-1 regulation.
EMI: Meet EN 55022 FCC Class A.
Remote ON/OFF: Available at [INH#] & [EN#] pins.
Power Fail Signal: Available at [FAL#] pin.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
Thermal Protection (OTP): Installed NTC for thermal
sensor at [DEG#] pin.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 300W continuous.
Output Connector: Positronic 47-pin PCIH47M400A1.
Line Regulation: Typ. 0.01%.
Load Regulation: Typ. ±0.2 to +/-1.0%.
Noise & Ripple: Typ. 1% Pk.-Pk. or 50mV,
whichever is greater.
OVP: Built-in at all outputs.
Adjustability: Available at VO1, 2 & 3.
Remote Sensing: Available at VO1 & sVO2.
Hot-Swap: Available.
N+1 Redundancy: Installed with internal OR-ing diodes at
all outputs for N+1 redundancy operation.
Current Sharing: Third-wire current sharing at VO1,2&3.
Over Current Protection (OCP): Installed in each rail.
Overload Protection (OLP): Fully protected against output
overload or short circuit. Typical 120% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 83 %.
Switching Frequency: 130K Hz.
Circuit Topology: Forward circuit.
Transient Response: Peak deviation is 160mV and
recovers within 0.256mS for 25% load-change.
Safety Standard: IEC 60950-1 Class I.
Construction: Eurocard 3U X 8HP X 160mm
CompactPCI format.
Operating Temperature: 0 to +50 °C at full load
with specified air flow.
Derates linearly to 50% at +70°C.
Storage Temperature: -40 to +85 °C.
Temperature Coefficient: Typ. ±0.02% / °C.
Cooling: At least 700 LFM moving air is required to
achieve full rating power 300W in a confined area.
Power Density: 7.7 Watts/ Cubic Inch.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
-103-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
QUAD OUTPUT
MAIN +VO1 @★#≡⊙
AUX. +VO2 ▲@★#≡⊙
AUX. +VO3 ▲@★≡⊙
AUX. -VO4 ⊙▲★
MODEL NO.
HDC301P-48B-490(E)
Min. Typ. Volt. Max. Min
Typ.
Volt. Max. Min.
Typ Volt. Max Pk. Min. Typ. Volt. Max. Pk.
2.0A 26.8A +5V
20A
+3.3V 40A
7.5A +12V 10A 11A 0A
40A
0A
0A
1A -12V 1.5A 1.7A
Symbol: "★" OVP built-in. "@" Adjustable. "#" Remote sensing. "≡" 3rd wire Load Sharing. "⊙" Installed with Or-ing diode.
"▲" Magnetic Amplifier.
Remark: Peak load less than 60sec. with duty cycle <10%.
Max. load is the continuous operating load of each rail. But the max. load of each rail can't be drawn from all outputs at the same time.
Total output maximum 300 W; Total combined current of +5 V and + 3.3 V not large than 50 A
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 666.0 g (23.5 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
DC
INPUT
ASSIGNMENT -Vin +Vin G
CNTR &PIN #
47
46
45
QUAD OUTPUT
VO1
S+
S- Adj. C.S.
1,2,
3,4
30
34
29
35
VO2
13,14,
15,16,
17,18
S+
33
Adj. C.S.
32
Mating connector: PCIH47F400A1.
-104-
41
STATUS/CONTROL
VO3
S+
C.S
VO4
20
36
44
21
DC COM EN#
5,6,7,8,9,
27
10,11,12,
19,24
DEG#
38
INH# FAL#
39
42