LinkCom Manufacturing Co., Ltd

LinkCom Manufacturing Co., Ltd
Model NO.
LCCH-080240
Model Name
Power Supply
Part NO.
PLCCH0080240
SIZE
208.4 * 72 * 38.55 mm【8.2 * 2.83 * 1.52 inch】
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OTP / OVP
◆ High Operating ambient Temp: -30℃~+60℃
(Refer to output dreating curve)
◆ Power Factor:>0.98@115Vac;>0.95@230Vac;@full load
◆ Safety: UL / PSE
◆ EMC: Meet CE
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 208.4 * 72 * 38.55 mm
◆ Dimension (L*W*H): 8.2 * 2.83 * 1.52 inch
◆ ROHS Compliant
Module : LCCH-080
240
*(9)
min.
SPECIFICATION
DC OUTPUT VOLTAGE (V)
*
*
*
*
*
*,# =SEE NOTES BELOW
LCCH-080240
MODEL
norm.
18
24
PRESET ACCURACY (%) *(8)
1
OUTPUT CURRENT(A) *(5)
3.4
O/P NOISE (P-P, mV) *(3)
240
1
LINE REGULATION (%) *(7)
1
LOAD REGULATION (%) *(6)
81.6 W
DC OUTPUT POWER
89%
EFFICIENCY(typ @Full Load)
SETUP,RISE TIME(typ.)
2S,500ms at full load 115VAC/230VAC
25ms at full load 115VAC/230VAC
HOLD UP TIME
INPUT VOLTAGE RANGE
90-305VAC, 127-431VDC, Normal:100-277VAC
INPUT FREQUENCY
ACTIVE POWER FACTOR
Range:47-63Hz, Normal:50-60Hz
PF>0.95 @230VAC, PF>0.98@115VAC at full load and rated output voltage
INRUSH CURRENT (typ)
COLD START 65A @ 230VAC
AC CURRENT
1.5A/115VAC 0.56A/230VAC
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
<0.45mA/264VAC
short circuit protection will restart automatically after the fault condition is removed
OVER TEMP. PROTECTION
OVER V, PROTECTION
*
max.
shut down and latch off o/p voltage , re-power on to recover
OPERATING TEMP.*(4)
-30 to +60℃@full load(Refer to output derating curve)
STORAGE TEMPERATURE
-40 to +80℃
RELATIVE HUMIDITY
10 to +90%, non-cond.
TEMP. COEFFICIENT
0.03% / ℃ (0-50℃, typ)
SAFETY
UL60950-1 / PSE
EMI
Meet CE EN55015
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH
DIMENSIONS(L*W*H)
208.4 * 72 * 38.5 mm【8.2 * 2.83 * 1.52 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Load regulation measured from 20% to Full load.
(7)Line regulation measured from 100VAC to 277VAC.
(8)Preset accuracy measured at normal load, 120VAC input.
(9)100% Production Tested.
※Reference
www.linkcom.com.tw For more information, please contact with: [email protected]
LinkCom Manufacturing Co., Ltd
Model NO.
LCCH-080240
Model Name
Power Supply
Part NO.
PLCCH0080240
SIZE
208.4 * 72 * 38.55 mm【8.2 * 2.83 * 1.52 inch】
DERATE
Dimensions
Unit :mm【inch】
※Reference
www.linkcom.com.tw For more information, please contact with :[email protected]