AN2023: Voltage Tracking with the ZL2005

Voltage Tracking with the ZL2005
Application Note
May 04, 2009
AN2023.0
Introduction
A common requirement for embedded system
design is to be able to control and guarantee
certain deterministic behavior of power sources
during start-up and shut-down. The industry shift
from the use of power planes to the use of a
distributed power architecture has given rise to the
need for an easy way control how power is applied
to a single chip and across a system during startup and shut down.
Digital-DC™ based power management and
conversion ICs from Zilker Labs contain voltage
tracking circuitry that makes the job of ensuring
deterministic start-up power supply simple for
system designers. There are several versions of
tracking supported by these devices. This
application note describes how to implement these
features using the built-in capabilities of Zilker
Labs ICs.
Overview
Power supply voltage tracking is a method of
controlling a number of power supply output
voltages. Powering a mix of integrated circuit
technologies requires careful consideration of
relative voltage levels between each technology. It
is usually very important that a certain power
supply rail does not exceed another power supply
rail’s level under any condition. An example of
this requirement is in the powering of a
microcontroller’s core voltage versus powering its
I/O pads. The core voltage is typically a lower
value than the I/O pad voltage. Because of certain
characteristics of the microcontroller’s integrated
technology the core voltage should not exceed the
I/O pad voltage. Therefore, voltage tracking is
implemented to keep the lesser power supply
1
voltage always below a master power supply
voltage.
The ZL2005 includes an analog input pin, VTRK,
which is used to track another voltage supply.
When the ZL2005 is configured to the voltage
tracking mode, the voltage applied to the VTRK
pin acts as a reference for the device’s output
regulation. Softstart settings are ignored and the
output will take on the turn-on/turn-off
characteristics of the reference voltage present at
the VTRK pin. The delay setting is only used on
the turn-off end of the tracking condition. The
delay setting sets the timeout for the tracking
voltage to turnoff in the event that the tracked
voltage does not achieve zero volts. Certain
tracking modes are also configurable to set the
percentage of tracking and response to the power
good signal.
In a tracking group, the ZL2005 device that is set
to the highest voltage within the group is defined
as the master device. This master device will
control the ramp delay and ramp rate of all
tracking devices and is not itself placed in the
tracking mode. The master device is configured to
the highest output voltage for the group since all
other device output voltages are meant to track
and never exceed the master device output
voltage. A delay of at least 10 ms must be
configured into the master device. This delay
allows the tracking devices to prepare their control
loops for tracking following the ENABLE pin
assertion. It is assumed for a tracking ZL2005
group, that all of the ENABLE pins are connected
together and driven by a single logic source.
1-888-INTERSIL or 1-888-468-3774|Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright © Intersil Americas Inc. 2009. All Rights Reserved
All other trademarks mentioned are the property of their respective owners
Application Note 2023
Tracking Mode Configured by Pin-strap
The configuration of a master ZL2005 is set by
pin-strap to achieve the desired output voltage
with delay and ramp time set accordingly. The
master device must have a pin-strap delay setting
of at least 10 ms (DLY1, DLY0 = open, open).
The master device is not configured to be in the
tracking mode.
The tracking devices are configured for tracking
mode and will simply track the voltage of the
master
in
the
manner
defined
by the master device and its own configuration.
The method for setting tracking mode by pin-strap
is to apply a resistor from SS1 to ground and
applying ground directly to SS0. The DLY1,
DLY0 pins are then used to set the delay time for
turn-off only. This ensures the tracking device will
turn off in the event that the tracked voltage does
not decay to zero within the amount of time set by
DLY1, DLY0. Refer to the ZL2005 data sheet for
the tracking mode pin-strap definitions.
Example of Tracking Configured by Pin-strap
ZL2005 Device Setting
Table 1 describes the pin-strap values applied to
each ZL2005EV1 to prepare the device on each
EVB
for
tracking
configuration.
Table 1. ZL2005 Device Settings
Pin
Master Device, EVB #1
SA1, SA0
V1, V0
SYNC
CFG
DLY1, DLY0
low, low (address x20)
high, low (2.5V)
open (auto detect)
low (SYNC pin is input)
open, open (10 ms delay,
minimum for master device)
open, high (20 ms ramp time &
PG delay)
open, high (70 mV/2.7 mΩ =
25.9A)
open, high (stable for power train)
open (4.5V min)
SS1, SS0
ILIM1, ILIM0
FC1, FC0
UVLO
2
Tracking Device, EVB #2
low, open (address x21)
open, low (1.2V)
open (auto detect)
low (SYNC pin is input)
high, low (50 ms turn-off delay)
16.2 kΩ, low (tracking mode, VLIM = VTRK,
50%)
open, high (70 mV/2.7 mΩ = 25.9A)
open, high (stable for power train)
open (4.5V min)
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
ZL2005EV1 EVB Connections and Settings for Tracking
The following steps describe the connections and settings of two ZL2005EV1 evaluation boards to
demonstrate the tracking mode. These connections and settings are valid for a tracking demonstration by pinstrap or PMBus command.
1. Connect the evaluation boards together using J13 of EVB #1 (address x20) and J12 of EVB #2
(address x21). The inter-device bus, ENABLE and SYNC pins are connected together via these
connectors.
2. Place the ENABLE jumper to the “MSTR EN” position on both boards.
3. Set the ENABLE switch of EVB #2 to the middle position (MONITOR).
4. Connect USB cable from PC to USB jack.
5. Connect RTN of EVB #1 to RTN of EVB #2.
6. Connect VIN of EVB #1 to VIN of EVB #2.
7. Connect the power source GND to RTN and V+ to VIN.
8. Turn the input power source on.
9. Enable outputs by the ENABLE switch on board #1
+Vin
GND
USB
Jumper
Jumper
EVB#1
ENABLE
EVB#2
ENABLE
Figure 1. EVB Connections for Tracking
3
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
Tracking Mode Configured by PMBus
The ZL2005 includes a PMBus command set that
supports configuration of the tracking mode. All
turn-on and turn-off parameters are set by PMBus
commands in the master device. All devices
within a tracking group should have their steadystate operating parameters set via PMBus,
including fault parameters.
Pin-strap Settings for Configuring by PMBus
Certain initial parameters must be set by pin-strap
when configuring the ZL2005 by PMBus. This
section describes only the pin-strap settings that
are required before configuring the tracking mode
through PMBus commands.
The device address is set for each ZL2005 by pins
SA1 and SA0. The address for each device can be
selected to fit a system’s SMBus addressing
scheme. The only restriction on device addressing
within a tracking group is the consideration of a
device’s phase position when placed in a
synchronized phase spreading tracking group.
Even this restriction is not necessary if the PMBus
command, INTERLEAVE, is used. Refer to
AN2013, “ZL2005 PMBus Command Set” for
description of the INTERLEAVE command.
The output voltage setting pins, V1 and V0, are
used to establish the maximum output voltage that
the device can be set to by a PMBus command.
The output voltage pin-strap setting is used to
provide a level of protection of the maximum
system operating range.
Other pin-strap settings can be configured to
achieve certain power up conditions. This is not
necessary since the PMBus commands allow the
user to set any and all parameters.
4
PMBus Commands for Tracking Mode
Many PMBus commands can be used to precisely
configure the ZL2005 to fit an application. This
section describes the PMBus commands that are
specific to configuring the tracking mode. These
commands for a tracking device are
TRACK_CONFIG,
TON_DELAY
and
VOUT_COMMAND.
See
Zilker
Labs
Application Note AN2013 for a complete list of
PMBus commands.
The TRACK_CONFIG command is used to
enable the tracking mode. This command also has
bit fields that set options for the tracking mode.
The tracking ratio bit sets the tracking percentage
to either 50% or 100%. A 50% tracking ratio is
typically selected unless the target voltage of the
tracking device is set to more than 50% of the
target voltage of the master device. In that case,
the 100% tracking ratio must be used. The control
of ramp-up behavior bit is a third settable option
in the TRACK_CONFIG command. This bit sets
the behavior of the output voltage during ramp-up
in the case that the master voltage does not reach
its target voltage and the tracking voltage does not
reach the power good threshold. This option
allows the tracking device to ramp-down without
having to exceed the power good threshold first.
A master device in a tracking group must have its
turn-on delay set to a minimum of 10 ms. This
provides time for initialization of the tracking
devices following the enable event. The master
tracking device set the delay for the tracking
group. The SS(1:0) pins or the TON_DELAY
command is used to do this.
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
The disable delay time for the tracking device
must be set to the sum of the disable delay time
and ramp down time for the master device plus
5ms. This allows the tracking device to disable
after tracking the master device to zero volts.
The output voltage of each ZL2005 circuit
can be set lower than the pin-strap setting by using
VOUT_COMMAND.
Note
that
VOUT_COMMAND does not immediately
change all VOUT margins and fault thresholds.
These VOUT parameters will only be recalculated
when the new VOUT_COMMAND value has
been stored by either STORE_USER or
STORE_DEFAULT then restored by a RESTORE
command or power cycled on the ZL2005 device.
Example of Tracking Configured by PMBus
ZL2005 EVB Setting
Table 2 describes the pin-strap values applied to
each ZL2005EV1 to prepare the device on each
EVB for tracking configuration by PMBus.
Table 2. Pin-strap Settings for Tracking Configured by PMBus
Pin
SA1, SA0
V1, V0
SYNC
DLY1, DLY0
SS1, SS0
ILIM1, ILIM0
FC1, FC0
UVLO
CFG
Master Device, EVB #1
low, low (address x20)
high, open (3.3V, set to 2.5V via
PMBus)
open
Tracking Device, EVB #2
low, open (address x21)
open, open (1.5V, set to 1.2V via PMBus)
open, open (10 ms delay,
minimum for master device)
open, open (10 ms ramp time &
PG delay)
open, high (70 mV/2.7 mΩ =
25.9A)
open, high (stable for power train)
open (4.5V min)
open
high, low (50 ms turn-off delay)
open
open, open (ignored for PMBus tracking)
open, high (70 mV/2.7 mΩ = 25.9A)
open, high(stable for power train)
open (4.5V min)
open
PMBus Configuration Files
The following text file listings are the PMBus
configuration files to place a device in either
master mode or tracking mode. These files are
referred to as PowerPlans. PowerPlans are
downloadable to the ZL2005 using the ZL2005
Evaluation Software.
For purposes of this
5
example, the PowerPlan for EVB #1 is
downloaded to the master device on the EVB set
for address 0x20. The PowerPlan for EVB #2 is
downloaded to the tracking device on the EVB set
for address 0x21.
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
Tracking Example – PMBus configuration file for master device on EVB #1
#ZL2005EV1_Tracking_EVB #1
#PowerPlan file
#
#PMBus CommandValue
#
#Erase user store
RESTORE_FACTORY
STORE_USER_ALL
STORE_DEFAULT_ALL
#
#Set output voltage of the first EVB to 2.5V
VOUT_COMMAND 0x5000
#
#Set output peak/valley current protection to 30 to -10A
IOUT_OC_FAULT_LIMIT 0xDBC0
IOUT_UC_FAULT_LIMIT 0xD580
#
#Set output average current protection to 25A to -8A
IOUT_AVG_OC_FAULT_LIMIT
0xDB20
IOUT_AVG_UC_FAULT_LIMIT
0xD600
#
#Set IOUT_SCALE to 2.7mOhms
IOUT_SCALE
0xC2B3
#
#Set IOUT_CAL_OFFSET to -3.5A
IOUT_CAL_OFFSET
0xC480
#
#Use Rdson current sense method with external tempco sensor
MFR_CONFIG
0xABC1
#
#Set temperature compensation at 4400ppm/ C
TEMPCO_CONFIG 0xAC
#
#PID taps
PID_TAPS
A=1634, B=-2799, C=1227
#
#NLR_CONFIG Enable,1.5%,No Outer,1.5%,3,3,0
NLR_CONFIG
0xA250
#
STORE_DEFAULT_ALL
RESTORE_DEFAULT_ALL
6
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
Tracking Example – PMBus configuration file for master device on EVB #2
#ZL2005EV1_Tracking_EVB #2
#PowerPlan file
#
#PMBus CommandValue
#
#Erase user store
RESTORE_FACTORY
STORE_USER_ALL
STORE_DEFAULT_ALL
#
#Set output voltage of the first EVB to 1.2V
VOUT_COMMAND 0x2666
#
#Set Tracking mode: Enable,limit=Vtarget,50%,decrease w/o PG
TRACK_CONFIG 0x85
#
#Set Time-off delay(2) = Toff delay(1) + Toff fall(1) + 5ms
TOFF_DELAY
25#ms
#
#Set output peak/valley current protection to 30 to -10A
IOUT_OC_FAULT_LIMIT 0xDBC0
IOUT_UC_FAULT_LIMIT 0xD580
#
#Set output average current protection to 25A to -8A
IOUT_AVG_OC_FAULT_LIMIT
0xDB20
IOUT_AVG_UC_FAULT_LIMIT
0xD600
#
#Set IOUT_SCALE to 2.7mOhms
IOUT_SCALE
0xC2B3
#
#Set IOUT_CAL_OFFSET to -3.5A
IOUT_CAL_OFFSET
0xC480
#
#Use Rdson current sense method with external tempco sensor
MFR_CONFIG
0xABC0
#
#Set temperature compensation at 4400ppm/ C
TEMPCO_CONFIG 0xAC
#
#PID taps
PID_TAPS
A=1634, B=-2799, C=1227
#
#NLR_CONFIG Enable,1.5%,No Outer,1.5%,3,3,0
NLR_CONFIG
0xA250
#
STORE_DEFAULT_ALL
RESTORE_DEFAULT_ALL
7
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
Tracking Example – Performance
Figure 2. Enable Sequence
Figure 3. Disable Sequence
Channel 1 = VOUT, EVB #1
Channel 2 = VOUT, EVB #2
Channel 3 = ENABLE (trigger)
Channel 4 = Power Good, EVB #2
Channel 1 = VOUT, EVB #1
Channel 2 = VOUT, EVB #2
Channel 3 = ENABLE (trigger)
Channel 4 = Power Good, EVB #2
Figure 2 shows the scope is set to trigger on the
ENABLE event. The ENABLE signal is the first
to go high. The next signal to change is the
beginning of the VOUT1 turn-on ramp since it has
been configured to be the master device of the
tracking group. It occurs 10 ms after ENABLE
(DELAY1 set to 10 ms). The time of the VOUT1
ramp is 20 ms (softstart set to 20 ms). VOUT2
then begins tracking at 50% of VOUT1. The ramp
time for VOUT2 is set by the combination of the
ramp time of VOUT1 and the VOUT2 target
voltage. Power Good 2 goes high 10ms after
VOUT2 is above the power good threshold (by
default, power good delay = softstart = 20 ms).
Figure 3 shows the scope is set to trigger on the
ENABLE event. The ENABLE signal is the first
to go low. The delay for VOUT1 to begin its turn
off is set to 10 ms. The ramp time for VOUT1 is
20 ms (softstart set to 20 ms).The next signal to
change is the VOUT2 turn off ramp since it has
been configured to track 50% of VOUT1. The
next signal to change is the Power Good 2 which
goes low after VOUT2 drops below the power
good threshold.
8
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
References
[1]
ZL2005 Data Sheet, Zilker Labs, Inc., 2006.
[2]
AN2013 – ZL2005 and PMBus™, Zilker Labs,
Inc., 2006.
Revision History
Date
Rev. #
July 10, 2006
1_0
Initial Release
October 3, 2006
1.1
Updated EVB picture on Page
3
May 4, 2009
AN2023.0 Assigned file number AN2023
to app note as this will be the
first release with an Intersil file
number. Replaced header and
footer with Intersil header and
footer. Updated disclaimer
information to read “Intersil
and it’s subsidiaries including
Zilker Labs, Inc.” No changes
to app note content.
9
Application Note Revision 5/04/2009
www.intersil.com
Application Note 2023
Zilker Labs, Inc.
4301 Westbank Drive
Building A-100
Austin, TX 78746
Tel: 512-382-8300
Fax: 512-382-8329
© 2006, Zilker Labs, Inc. All rights reserved. Zilker Labs, Digital-DC and the Zilker Labs Logo are trademarks
of Zilker Labs, Inc. All other products or brand names mentioned herein are trademarks of their respective holders.
Specifications are subject to change without notice. Please see www.zilkerlabs.com for updated information.
This product is not intended for use in connection with any high-risk activity, including without limitation, air
travel, life critical medical operations, nuclear facilities or equipment, or the like.
The reference designs contained in this document are for reference and example purposes only. THE REFERENCE DESIGNS ARE PROVIDED "AS IS" AND "WITH ALL FAULTS" AND INTERSIL AND IT’S
SUBSIDIARIES INCLUDING ZILKER LABS, INC. DISCLAIMS ALL WARRANTIES, WHETHER
EXPRESS OR IMPLIED. ZILKER LABS SHALL NOT BE LIABLE FOR ANY DAMAGES, WHETHER
DIRECT, INDIRECT, CONSEQUENTIAL (INCLUDING LOSS OF PROFITS), OR OTHERWISE,
RESULTING FROM THE REFERENCE DESIGNS OR ANY USE THEREOF. Any use of such reference
designs is at your own risk and you agree to indemnify Intersil and it’s subsidiaries including Zilker Labs, Inc.
for any damages resulting from such use.
10