RS-232/RS-485

Implementing a Three Pin, Half-Duplex, Dual Protocol
(RS-232/RS-485) Interface Using the ISL81387 or ISL41387
®
Application Note
January 25, 2008
AN1378.0
By Jeff Lies
Introduction
The simplest RS-232 or RS-485 bidirectional interface
requires only three pins. For RS-232, those pins are the
single-ended signals Transmit Data (TXD), Receive Data
(RXD) and GND, whereas in the RS-485 interface, the pins
are GND, and the bidirectional differential data lines Data+
and Data-. A three pin RS-485 interface requires a half
duplex configuration where the transmitter (Tx) and receiver
(Rx) terminals of the same polarity (inverting or
non-inverting) are connected together, as shown in Figure 1.
Many applications (e.g., single board computers) need
flexibility in defining the protocol of a port. Dual protocol ICs
are ideal for this task, as the user can switch between the
protocols (RS-232 and RS-485) at will, but it isn’t always
obvious how to implement the desired configuration.
loopback, etc.). One of these sub-modes is particularly
useful for this three pin half duplex application, as will be
shown in a later section.
The DZ/SLEW pin is the Z Transmitter input for RS-232
mode, or it selects the Tx output slew rate (fast or medium)
in RS-485 mode. Drive the SLEW pin high for RS-485 data
rates greater than 800kbps, or drive it low for data rates of
800kbps or less.
+5V
+
0.1µF
VCC 18
CHARGE PUMP
A
232
4
485
+5V
0.1µF
17
R
RA
R
+
VCC
RXOUT
R
RXEN
RS-485
INTERFACE
TXEN
DATADATA+
B
D
LOGIC
INTERFACE
Y
232
5
232
6
15
D
TXIN
RB
DY
D
GND
Z
7
8
485
14
D
232
DEN
485/232
FIGURE 1. STANDARD RS-485 HALF DUPLEX
TRANSCEIVER
RXEN
Understanding the ISL81387, ISL41387
Figure 2 details the basic ISL81387 and ISL41387
architecture. As you can see, the two Rx input pins (A and B)
are shared between the differential RS-485 Rx, and two
single-ended RS-232 Rx. Likewise, the two Tx output pins
(Y and Z) are shared between the differential RS-485 Tx,
and the two RS-232 Tx. In most RS-232 modes, all (two of
each) of the single ended transmitters and receivers are
enabled. This can cause some issues which will be
described in the next section.
Note: The ISL81387, ISL41387 don’t follow the standard
convention where A and Y are the noninverting RS-485
signals, and where B and Z are the inverting signals. Use
care to ensure that the ISL81387, ISL41387 signals match
the polarity of the bus signals to which they connect.
The 485/232 pin selects the bus protocol, while the
combined states of the DEN, RXEN, and ON pins not only
control whether the Rx and Tx outputs are enabled, but they
also set the ISL81387, ISL41387’s sub-mode (e.g., SHDN,
1
16
R
GND
ON
DZ/SLEW
9
12
13
10
FIGURE 2. ISL81387, ISL41387 FUNCTIONAL DIAGRAM
Configuring the ISL81387, ISL41387 for
RS-485 Half Duplex Mode
Focusing on the RS-485 protocol, it’s not unreasonable to
think that you might be able to use the ISL81387, ISL41387
internal loopback mode to achieve half duplex functionality.
In reality, the Rx used for the loopback function is not an
RS-485/RS-422 compatible Rx, so it doesn’t operate
properly when receiving RS-485/RS-422 compliant data
streams.
Nevertheless, it is a simple matter to externally connect the
ISL81387, ISL41387 for half duplex operation. One simply
shorts the noninverting Tx output and Rx input pins (pins 5
and 7) together, and shorts the inverting Tx output and Rx
input pins (pins 4 and 6) together, as shown in Figure 3 for
the ISL81387. The internal RS-232 Tx and Rx are all
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2008. All Rights Reserved
All other trademarks mentioned are the property of their respective owners.
Application Note 1378
disabled in RS-485 mode, so they have no impact on
RS-485 operation. The Tx data for transmission is applied to
the DY input (pin 15), and the received data is read via the
RA output (pin 17). ON, RXEN, DEN, and 485/232 all
connect to a “Logic 1”, as shown in line 8 of Table 1, for a
transceiver with an enabled Rx to echo back the TXD.
+5V
C1
0.1µF
+ 0.1µF
1
+
C1+
DATA-
2
C120
C2+
+
19
C24 A
DATA+
5 B
C2
0.1µF
V+
3
V- 11
R
RA 17
12
RXEN
C1
0.1µF
C2
0.1µF
+ 0.1µF
1
+
2
20
+
19
18
C1+
VCC
V+
C1C2+
D
DY 15
3
V- 11
C2-
4 A
RA 17
R
RXEN 12
+ C3
0.1µF
5 B
C4
0.1µF
+
R
6 Y
DY 15
D
7 Z
RXD
+ C3
0.1µF
C4
0.1µF
+
RXD
LOGIC 1
RB 16
DZ 14
D
DEN
9
LOGIC 1
485/232
6 Y
7 Z
+5V
RXD232
18
VCC
.
TXD
ON
TXD
LOGIC 1 OR
LOGIC 0
LOGIC 1
8
LOGIC 0
13
GND
10
VCC FOR FAST
RS-485 DATA
RATE; GND FOR
SLOWER DATA
RATES
DEN
14
DZ/SLEW
485/232
ON
9
LOGIC 1
8
13
GND
10
FIGURE 3. ISL81387 CONFIGURED FOR HALF-DUPLEX
RS-485 OPERATION
But what happens when you switch the ISL81387, ISL41387
to RS-232 mode? Figure 4 illustrates the enabled functions
and the connections in this instance. As you can see, each
Rx input shorts to a Tx output, and because both Tx outputs
enable in unison, data reception and transmission must be
mutually exclusive. Even if this was acceptable, the RS- 232
Tx driven by the TXD signal (per the Figure 3 RS-485 I/O
definition) is externally shorted to the Rx that outputs the
RXD signal. Since RS-232 ports expect TXD and RXD to be
separate connector pins (because there is no requirement
that the Tx and Rx on the other end of the cable be
tri-statable) the RS-232 side TXD or RXD must be routed to
the other Tx or Rx. This could be accomplished using
external switches on the logic side, but needless to say,
making it work would be a mess at best.
FIGURE 4. RS-232 CONNECTIONS WHEN ISL81387 IS
CONFIGURED FOR HALF DUPLEX 485 MODE
Special Mode Solves the Problems
The ISL81387, ISL41387 includes a mode specifically
designed for this application. In this mode, only one Rx and
one Tx enable in RS-232 mode, and the enabled devices are
the ones that don’t share bus pins (see Figure 5) therefore,
simultaneous transmission and reception is possible. Setting
ON = DEN = 485/232 = Logic 0, and RXEN = Logic 1 selects
this single transceiver mode (see Table 1, line 3).
+5V
C1
0.1µF
C2
0.1µF
+ 0.1µF
1
+
2
20
+
19
18
C1+
VCC
V+
C1C2+
V- 11
C2-
TXD232
4
A
RXD232
5
B
6
Y
3
X
R
D
VCC
7
Z
X
D
C4
0.1µF
+
RXD
RA 17
RXEN 12
R
+ C3
0.1µF
RB 16
DY 15
DZ 14
DEN 9
485/232
ON
8
LOGIC 1
TXD
VCC FOR FAST
RS-485 DATA
RATE; GND FOR
SLOWER DATA
RATES
LOGIC 0
13
GND
10
FIGURE 5. RS-232 CONNECTIONS WITH ISL81387 IN
SINGLE TRANSCEIVER MODE AND
EXTERNALLY CONNECTED FOR HALF DUPLEX
2
AN1378.0
January 25, 2008
Application Note 1378
TABLE 1. EXCERPT FROM THE ISL81387 FUNCTION TABLE IN THE ISL81387, ISL41387 DATA SHEET
LINE
NUMBER 485/232
RECEIVER
OUTPUTS
INPUTS
ON
RXEN
DEN SLEW
DRIVER OUTPUTS
RA
RB
Y
Z
COMMENTS
MODE
1
0
1
0
0
NA
High-Z
High-Z
High-Z
High-Z
Disabled Tx and Rx
RS-232
2
0
0
0
1
NA
High-Z
High-Z
ON
High-Z
Single Tx Mode
RS-232
3
0
0
1
0
NA
High-Z
ON
ON
High-Z
Single Transceiver Mode
RS-232
4
0
0
1
1
NA
ON
ON
ON
ON
Loopback w/ 2 Transceivers
RS-232
5
X
0
0
0
X
High-Z
High-Z
High-Z
High-Z
Shutdown Mode
Shutdown
6
1
X
0
1
1/0
High-Z
High-Z
ON
ON
Rx Disabled
RS-485
7
1
X
1
0
X
ON
High-Z
High-Z
High-Z
Tx Disabled
RS-485
8
1
1
1
1
1/0
ON
High-Z
ON
ON
Rx Enabled for Tx Echo
RS-485
9
1
0
1
1
1/0
ON
High-Z
ON
ON
RS-485 Loopback
RS-485
As with the RS-485 mode, the Tx input is DY (pin 15), so the
TXD input connection is the same for both modes. However,
unlike the RS-485 mode that uses RA to output the received
data, the single transceiver RS-232 mode outputs received
data on the RB output. The simple solution to this quandary
is to connect RA and RB together, so the RX data is read
from the proper output in either mode. This works because
RB is disabled in RS-485 mode, while conversely RA is
disabled in this single transceiver RS-232 mode, so the two
Rx outputs are never enabled at the same time (see Table 1,
lines 3 and 8). The unused DZ/SLEW pin should be
connected to VCC or GND, depending on the slew rate
required for the RS-485 data rate.
Note that in this RS-232 mode, DEN and RXEN no longer
directly control the Tx and Rx enables. If DEN switches to a
Logic 1, then both RS-232 Tx enable (see Table 1, line 4) in
loopback mode, while changing RXEN to a Logic 0 sends
the ISL81387, ISL41387 into the low power shutdown state
(see Table 1 line 5).
If just an RS-232 Rx enable function is desired (i.e., Tx is
always enabled), this can be accomplished by driving DEN
high at the same time that RXEN is driven low (i.e., DEN is
inverted from RXEN, see Table 1 line 2).
Single transceiver mode doesn’t provide for separate control
of the Tx enable, so if the RS-232 Tx must be disabled, the
only way to accomplish this is to also disable the Rx. This
can be accomplished by forcing the ISL81387, ISL41387
into SHDN (simply drive RXEN low, see Table 1 line 5), or by
driving ON high while simultaneously driving RXEN and
DEN low (see Table 1,line 1). Note that SHDN turns off the
charge pumps, so the reenable times are longer than the
enable times if just the Tx and Rx are disabled.
To switch to the standard RS-485 mode, simply drive the
485/232 and ON pins high (see Table 1, lines 6, 7, and 8).
DEN and RXEN now control the enable states of the Tx and
Rx as would be expected (see Table 1, lines 6 and 7).
3
Simplified Connections
Figure 6 shows the simplest connections to achieve the
three-pin, half duplex configuration. With these connections,
the ISL81387, ISL41387 operates in one of only three
modes: RS-232 single transceiver, RS-485 Transmit, RS485 receive (lines 3, 6, and 7 in Table 1). If the RS-485 mode
requires echo back during transmission (i.e., Rx always
enabled), simply strap RXEN high, and the ISL81387,
ISL41387 now operates in only two modes (lines 3 and 8 in
Table 1).
The simplified configuration’s main advantage is that the
logic side interface requires only four I/O pins. If SHDN or
loopback modes are needed, then more I/O pins must be
dedicated to controlling the ISL81387, ISL41387.
+5V
C1
0.1µF
C2
0.1µF
+ 0.1µF
1
+
2
20
+
19
C1+
18
VCC
3
+ C3
0.1µF
V-
11
C4
0.1µF
+
RA
17
RB
16
V+
C1C2+
C2-
TXD232/D-
4
A
RXD232/D+
5
B
6
Y
DY
15
7
Z
RXEN
12
DEN
14
STRAP TO:
1 = FAST RS-485
DATA RATE
0 = SLOWER
DATA RATES
DZ
485/232
ON
9
8
13
RXD
TXD
1 = 485 TX
0 = 232 OR
485 RX
1 = 485
0 = 232 1 XCVR
GND
10
FIGURE 6. SIMPLEST CONNECTIONS FOR THREE PIN HALF
DUPLEX DUAL PROTOCOL OPERATION
AN1378.0
January 25, 2008
Application Note 1378
SHDN and Loopback Modes of Operation
Advantages of Using the ISL41387
SHDN and loopback are useful modes of operation. SHDN
puts the ISL81387, ISL41387 into their lowest power mode,
while loopback routes the Tx outputs back through the Rx
(i.e., returns TXD on RXD) to allow some level of I/O port self
test capability. Unfortunately, the half duplex external
connections preclude utilizing loopback in RS-232 mode.
Choosing the ISL41387, QFN version offers even more
advantages, not the least of which is the small 6mmx6mm
footprint. This version also offers an RXEN pin, which is an
active low version of the RXEN pin. When implementing the
circuit in Figure 6, one simply connects RXEN (QFN pin 17)
and DEN together (with RXEN strapped to GND) to eliminate
the external inverter. Another advantage is the built-in level
shifter that is extremely useful if the logic ICs (UART,
microcontroller, etc.) are powered by a supply voltage lower
than the 5V supply of the ISL41387. Simply tying the
ISL41387’s VL pin (QFN pin 31) to the lower supply voltage
shifts the logic pin input thresholds and output voltages to
values compatible with that lower supply voltage. A third,
slower (115kbps) RS-485 speed option is also available on
the ISL41387. This option uses even slower edge rates than
the medium speed version, for EMI sensitive designs, or to
allow longer bus lengths, or to minimize the risk of
termination issues on slower data rate networks.
Adding just the SHDN mode is easy for either protocol. The
only change required to Figure 6 is to connect an I/O pin to
RXEN, rather than inverting it from DEN. SHDN is invoked
by driving ON, RXEN, and DEN low, as shown in Table 1,
line 5.
Adding loopback to RS-485 mode requires one more I/O pin
to independently drive the ON input (so a total of 6 I/O pins
for two protocols with SHDN and RS-485 loopback). With the
485/232 pin high, driving ON low with DEN and RXEN high
enables loopback (see Table 1, line 9).
For more information on all of these special features, please
refer to the ISL81387, ISL41387 data sheet.