FUSE SELECTION GUIDE

FUSE SELECTION GUIDE
A quick reference guide to selecting fuses for electronic applications
Max. Voltage
< 250 VAC/VDC
Mounting
Surface Mount Fuses
Through-Hole
PICO
SMF Fuse
®
NANO 2® Fuse
Fuse Type
Thin Film Fuse
Ceramic Chip Fuse
–55°C to 90°C
1206
2410
Fuse/FH Assy.
(2410)
4012
0402
0603
1206
1206
0603
1206
1206
7.24 × 4.32 ×
3.05 mm
Body Material
Ceramic
Ceramic
Ceramic/
Thermoplastic/
Metal
Ceramic
FR4
FR4
FR4
FR4
Ceramic
Ceramic
Ceramic
Thermoplastic
Current Rating
1 A to 10 A
62 mA to 15 A
62 mA to 10 A
20 A to 40 A
250 mA to 5 A
250 mA to 5 A
7A
125 mA to 5 A
250 mA to 6 A
250 mA to 8 A
10 A to 20 A
62 mA to 5 A
50 A @ 32 VDC
50 A @
63 VAC/VDC
50 A @
32 VAC/VDC
150 A @ 32 VDC
50 A @ 48 VAC
50 A @ 75 VDC
50 A @
50 A @
100 A @ 125 VAC
125 VAC/VDC
125 VAC/VDC
35 A @ 32 VDC
500 A @ 72 VDC
300 A @ 32 /VDC 300 A @ 32 VDC
35 A @
32 VAC/VDC
35 A @
24 VAC/VDC
50 A @
63 VAC/VDC
TE
MICRO™ Fuse
Hazardous
Area Fuse
–55°C to 150°C
Footprint
Interrupt Rating
PICO® Fuse
13 × 8mm
Ceramic body
Thermoplastic
coated in epoxy
62 mA to 30 A
50 mA to 6.3 A
50 A @ 125 VAC 50 A @ 125 VAC
100 A @ 125 VAC
300 A @ 125 VDC 300 A @ 125 VDC
Metal/
Thermoplastic
Polyamide
2 mA to 5 A
0.062 A to 5 A
50 A @ 125 VAC
10 kA @
125 VAC/VDC 300 A @ 125 VDC
Characteristics / Agency Approvals
Fast Acting UL
451/453
(125 VAC/VDC)
395 (125 VAC)
Fast Acting IEC
Fast Acting UR
448
(125 VAC/VDC)
458
(48 VAC/75 VDC)
451/453
(125 VAC/VDC)
154
(125 VAC/VDC)
456
435 (32 VDC)
(125 VAC/72 VDC)
157
(125 VAC/VDC)
467
(32 VAC/VDC)
429007.L
(24 VAC/VDC)
466
(63 VAC/VDC)
438 (32 VDC)
441 (32 VDC)
437
(63 VAC/VDC)
440
(32 VAC/VDC)
501 (32 VDC)
251/253
(125 VAC/VDC)
459
(125 VAC/VDC)
275
(32 VAC/VDC)
SLO-BLO® Fuse UL
272
(125 VAC/VDC)
273
(125 VAC/VDC)
396 (125 VAC)
Time Lag IEC
SLO-BLO® Fuse UR
Hazardous Area
Protection
littelfuse.com
452/454
(125 VAC/VDC)
449
(125 VAC/VDC)
154T
(125 VAC/VDC)
157T
(125 VAC/VDC)
468
(63 VAC/VDC)
469
(63 VAC/VDC)
471
(125 VAC/VDC)
460
472
(125 VAC/VDC) (125 VAC/VDC)
473
(125 VAC/VDC)
259
(125 VAC/VDC)
≥ 250 VAC
Max. Voltage
Mounting
Through-Hole /Fuseholder
Fuse Type
TR/TE
Barrier
Footprint
8.40 × 3.02mm
Surface Mount Fuses
FLAT-PAK®
Fuse
Cartridge
3.6mm × 10mm
4.5mm × 15mm
(2 AG)
6 × 32mm
(3 AG/3 AB)
5 × 20mm
PICO® Fuse
Body Material
Thermoplastic
Ceramic
Ceramic
Glass
Ceramic
Glass
Ceramic
Glass
Thermoplastic
Current Rating
40 mA and up to 10 A
depending on series
0.05 A to 0.25 A
0.1 A to 10 A
250 mA to 10 A
0.050 A to 20 A
0.032 A to 16 A
0.01 A to 40 A
0.01 A to 30 A
0.062 A to 5 A
0.062 A to 5 A
35 A @ 250 VAC up to
10kA @ 125 VAC
35 A @ 250 VAC 100 A @ 250 VAC
35 A @ 250 VAC
1000 A @ 250 VAC
1500 A @ 250 VAC
35 A @ 250 VAC up to
35 A @ 300 VAC
up to 50 A @
up to
50 A @ 250 VAC
20kA @ 500 VAC
400 A @ 250 VAC
150 A @ 250 VAC
100 A @ 350 VAC
250 VAC
200 A @ 250 VAC
10kA @ 1000 VAC
35 A @ 250 VAC
up to 150 A @ 250 VAC
depending on series
Fast Acting UL
373 (250 VAC)
874 (250 VAC)
Fast Acting IEC
370 (250 VAC)
876 (250 VAC)
Fast Acting UR
804 (250 VAC)
807 (300 VAC)
808 (250 VAC)
SLO-BLO® Fuse UL
374 (250 VAC)
875 (250 VAC)
Time Lag IEC
372 (250 VAC)
382 (250 VAC)
383 (300 VAC)
392 (250 VAC)
400 (250 VAC)
877 (250 VAC)
SLO-BLO® Fuse UR
369 (300 VAC)
383 (300 VAC)
4000 A @
250 VAC/VDC
EBF
6.35 × 10.16mm
Cermic body
coated in epoxy
Interrupt Rating
EBF
FLAT-PAK®
Fuse
NANO 2® Fuse
15.24 × 6.35mm
10.1 × 3.12mm
12.1 × 4.5mm
10.1 × 3.12mm
(Telecom Nano)
10.5 × 4.5mm
Thermoplastic
Thermoplastic
Thermoplastic
Ceramic
Ceramic
Ceramic
Thermoplastic
2 A to 10 A
2 A to 10 A
0.062 A to 5 A
500 mA to 5 A
500 mA to 6.3 A
500 mA to 2 A
0.5 A to 5 A
60 A @ 600 VAC
150 A @
250 VAC/VDC
100 A @
350 VAC/VDC
50 A @ 250 VAC
100 A @ 350 VAC 100 A @ 350 VAC
50 A @ 250 VAC 50 A @ 250 VAC 100 A @ 250 VAC
50 A @ 125 VDC 50 A @ 125 VDC
263 (250 VAC)
202 HXG/URG
(250 VAC)
Characteristics / Agency Approvals
224(250 VAC)
225(250 VAC)
235 (250 VAC)
216 (250 VAC)
216SP (250 VAC)
324/314(250 VAC)
312/318
(250 VAC)
217 (250 VAC)
464 (250 VAC)
208 (350 VAC)
220 (300 VAC)
202 (250 VAC)
229(250 VAC)
230(250 VAC)
233 (125 VAC)
234 (250 VAC)
215 (250 VAC)
215SP (250 VAC)
477(500 VAC)
326/325 (250 VAC)
313/315
(250 VAC)
218 (250 VAC)
219XA high i2t
(250 VAC)
Electronic Ballast
600 VAC
1000 VAC
Audio
Hazardous Area
Protection
447 (350 VAC)
446 (350 VAC)
505 (500 VAC)
461(600 VAC)
285 (250 VAC)
242
(250 VAC/VDC)
NOTE:
DC Protection ≥ 250 VDC
Mounting
Through-Hole
Fuse Type
Interrupt Rating
462
(350 VAC/VDC)
443 (250 VAC)
508 (1000 VAC)
Max. Voltage
Footprint
Body Material
Current Rating
203 HXG/URG
(250 VAC)
203 (250 VAC)
477 (500 VAC)
977 (500 VAC)
462
(250 VAC/VDC)
465 (250 VAC)
209 (350 VAC)
500 VAC
485 (250 VAC)
Surface Mount Fuses
Cartridge
5 × 20mm
Ceramic
0.5 A to 16 A
400 A@400 VDC up to
1500 A@400 VDC, 200 A@450 VDC
TE
6 × 32mm
Ceramic
0.315 A to 30 A
20kA@500 VDC, 10kA@600 VDC,
10kA@1000 VDC
Thermoplastic
2 A to 5 A
10kA@250 VDC to 450 VDC
NANO 2® Fuse
10.5 × 4.5mm
Thermoplastic
0.5 A to 5 A
150 A@250 VDC,
100 A@350 VDC
12.1 × 4.5mm
Ceramic
0.5 A to 3.15 A
100 A@600 VDC
This tool should ONLY be used as a quick reference guide to suggest a starting point in the overcurrent
selection process. After the initial parts have been selected, the designer should reference the below link titled
Fuseology. The Fuseology document includes a Step-by-Step selection process to select the correct fuse for the
application. Once a part has been selected, the designer should retrieve the actual datasheet from Littelfuse.
com. Littelfuse always recommends that application testing be conducted to verify the correct part selection.
In order to use this quick reference guide, the designer just has to know a few of the key parameters such
as Max Voltage, Rated Current, Interrupting Rating, Mounting Type, Footprint, Fast Acting or Time Lag, and
Safety Certifications.
Fuseology-Fuse Characteristics, Terms and Consideration Factors:
http://www.littelfuse.com/data/en/Product_Selection_Guides/Fuseology.pdf
Characteristics/Agency Approvals
250 VDC UR
450 VDC UR
400 VDC Time Lag IEC
450 VDC Time Lag IEC
500 VDC Fast Acting UR
600 VDC Fast Acting UR
1000 VDC Fast Acting UR
littelfuse.com
808 (250 VDC to 450 VDC)
808 (250 VDC to 450 VDC)
462 (250 VDC)
477 (400 VDC)
977 (450 VDC)
505 (500 VDC)
506 (600 VDC)
508 (1000 VDC)
485 (600 VDC)
091012
EC118N