LDC-150 Series
Compact, LED, 150W
Constant Current
AC/DC Power Supply
Key Features:
• 150W Output Power
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• UL 8750 Approved
Parameter
• Constant Current Output
Input Voltage Range
• Active PFC
Input Frequency
Inrush Current, See Note 1
• 90 - 305 VAC Input
• IP65 / IP67 Rated
Conditions
230 VAC
115 VAC
230 VAC
264 VAC
0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
See Note 2
115 VAC
230 VAC
277 VAC
Input Current
• Meets EN 55015, EN 61547
• Dimming Function
• >50 kHour Life Expectancy
• Lightning Surge Protection
• Over Volt/Temp Protection
Min.
90
127
47
Power Factor Correction
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
Leakage Current
Typ.
Max.
305
431
63
75
2.10
0.90
0.80
Units
VAC
VDC
Hz
A Pk
A
10
1.5
0.5
%
S
0.75
mA
Max.
Units
%
%
V P-P
%
mS
°C
107
%IOUT
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Output Ripple Current
Hold-Up Time
Over Temperature Protection
Short Circuit Protection
Overload Protection
Conditions
Min.
VIN = Min to Max
See Note 4
Typ.
±5.0
±1.0
2.0
±5.0
115 VAC 12.0
±10%, Autorecovery
85
Continuous (Autorecovery)
Autorecovery
95
General
Parameter
Conditions
Min.
Typ.
Max.
Units
Input to Output 3,750
Input to FG 2,000
VAC
Output to FG
500
Input to Output
Input to FG 100 M / 500 VDC / 25°C / 70% RH
Output to FG
Isolation Voltage, 60S
Insulation Resistance
EMI Characteristics
Parameter
EMI
EMS
Surge
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Standard
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Case Size
Weight
See Mechanical Diagrams (Page 4)
33.1 Oz (950g)
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
220
kHours
See Note 5
50
kHours
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Output
Model
Number
Current
OVP Level
Output
Power
Efficiency
Max (mA)
Adj. Range (mA)
Voltage
Range (VDC)
LDC-150-2450 x
2,450
1,650 - 2,450
32 - 58
62 - 80
142
91
LDC-150-3150 x
3,150
2,000 - 3,150
32 - 49
54 - 73
154
91
LDC-150-3500 x
3,500
2,200 - 3,500
27 - 42
49 - 65
147
91
LDC-150-4550 x
4,550
2,750 - 4,550
25 - 35
41 - 55
159
91
(VDC)
(W)
(%, Typ)
Package Type
Model
LDC-150-xxxx A
LDC-150-xxxx B
Ingress Protection
IP65
IP67
Notes:
1. Inrush current is given for a cold start
at 25°C.
2. Total Harmonic Distortion (THD) is
specified with an input of 230 VAC/50
Hz at full load.
3. Turn on delay is specified at full load.
4. Ripple & noise is measured at 20 MHz.
Connection to the unit is made with a 0.1 µF
ceramic capacitor and a 22 µF electrolytic
capacitor connected in parallel.
5. Life expectancy is calculated at 230 VAC,
full load and a case temp of +70°C.
6. Recovery from an over voltage fault is
automatic.
Dimming Function
Adjust by internal, variable resistor
Adjust by external resistor, DC voltage level or PWM signal
Derating Curve: Temperature
Efficiency vs Load: LDC-150-4550
292 Page Street Ste D Stoughton, MA 02072
Derating Curve: Input Voltage
PFC vs Load: LDC-150-4550
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Functional Block Diagram
Dimming Mode: B Model
With the LDC-150 “B” model, the output current level can be adjusted (Dimmed) by three different methods; Resistive, Analog or
Digital. Adjustments are made using the +DIM and -DIM inputs.
Resistive: Connect a 0.1 to 10 k resistor between the DIM+ (Blue) and DIM- (White) wires
Input Frequency
10 k
20 k
30 k
40 k
50 k
60 k
70 k
80 k
90 k
100 k
Open
Percentage of Rated Current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Analog: Apply 1 VDC to 10 VDC level between the DIM+ (Blue) and DIM- (White) wires
Adjust Voltage
Percentage of Rated Current
1 VDC
2 VDC
3 VDC
4 VDC
5 VDC
6 VDC
7 VDC
8 VDC
9 VDC
10 VDC
Open
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Digital: Apply a PWM signal (100 Hz - 3 kHz) between the DIM+ (Blue) and DIM- (White) wires
Duty Cycle
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Open
Percentage of Rated Current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Notes:
1. The -DIM (White) and -LED (Black) wires should not be connected.
2. The Dimming function will not turn the lighting fixture totally off. For more info on how to do this, please contact the factory
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions: A Model
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Blue
Field Ground
AC-Line
AC-Neutral
Black
Red
-LED
+LED
Mechanical Dimensions: B Model (Dimming Function)
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Blue
Field Ground
AC-Line
AC-Neutral
White
Blue
-DIM
+DIM
Black
Red
-LED
+LED