MPM-10IS Datasheet - Micropower Direct

MPM-10IS Series
Board Mount, 10W
Single & Dual Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 10W Output Power
• Universal 85-265 VAC Input
• EN 60950 Approved (UL)
• ErP Directive Compliant
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Meets EN 55022 B
• >300 kHour MTBF
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Conditions
Min.
Typ.
Max.
85
265
47
440
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Meets CISPR Pub. 22/FCC Class B
Inrush Current
EMI
Units
VAC
Hz
A Pk
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 3
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±1.0
VIN = Min to Max
±0.5
IO = Min to Max
±0.5
IO = Min to Max
±2.5
3.3V & 5.0 VDC Output
1.5
All Other Outputs
0.8
115 VAC, 60 Hz
20
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
See Note 4 105
Max.
Units
±2.0
±1.0
±1.0
±5.0
1.8
1.0
%
%
%
%
%VP-P of VO
mSec
%/°C
% of VO
% of INOM
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
Conditions
Input to Output
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
EMC Compliance
Switching Frequency
Min.
3,000
4,700
100
Typ.
Max.
Units
VAC
VAC
M
EN 55022 Level B
EN 61000-4-2 Level 3
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-25
+25
+71
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Case Size
Case Material
Weight
2.52 x 1.77 x 0.75 Inches (64.0 x 45.0 x 19.0 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
3.23 Oz (92g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
ECO Design
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
300
EN 60950
IEC 61140 Class II
ErP Directive 2009/125/EC
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output 1 (Vout 1)
Current (A)
Voltage
Output 2 (Vout 2)
Current (A)
Current (A)
Voltage
(µF, Max)
Efficiency
(%, Typ)
115 VAC
230 VAC
(VDC)
Max.
Min.
MPM-10S-03IS
0.137
0.075
3.3
2.000
0.200
3,900
70
MPM-10S-05IS
0.199
0.075
5.0
2.000
0.200
3,300
73
MPM-10S-12IS
0.191
0.075
12.0
0.833
0.083
2,200
76
MPM-10S-15IS
0.191
0.075
15.0
0.666
0.066
2,200
76
MPM-10S-24IS
0.190
0.075
24.0
0.416
0.042
1,000
76
MPM-10D-12IS
0.172
0.075
+12.0
+0.380
+0.038
-12.0
-0.380
-0.038
±1,000
77
MPM-10D-15IS
0.169
0.075
+15.0
+0.300
+0.030
-15.0
-0.300
-0.030
±1,000
77
Other output combinations are available
Contact the factory for details at:
[email protected]
(VDC)
Capacitive
Load
Max.
Min.
Derating Curve
Notes:
1. Load regulation is measured for an output change of 0% to 100% at
nominal input line. For multiple output models, the loads are balanced.
2. Operation at no-load will not damage these units. However, they may
not meet all specifications.
3. Output short circuit protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limiting
circuit.
5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input
for protection.
Model Number
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
AC-Neutral AC-Neutral
2
AC-Line
AC-Line
3
-Vo
-Vo
4
NC
Common
5
+Vo
+Vo
NP = No Connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]