GE24 series

GE24
24W AC-DC Interchangeable Industrial Adaptor
series
■ Features :
Interchangeable AC plugs (plug kit sold separately)
Universal AC input / Full range
No load power consumption< 0.075W
Energy efficiency Level Ⅵ
Comply with EISA 2007/DoE and EU ErP
Class II power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
Interchangeable AC plug specifically for GE series
TYPE
ORDER NO.
Australian type
U.K type
European type
US type
Mix four type
AC plug-AU
AC plug-UK
AC plug-EU
AC plug-US
AC plug-MIX
SPECIFICATION
DC VOLTAGE
OUTPUT
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
GE24 I 07
GE24 I 09
GE24 I 12
GE24 I 15
GE24 I 18
GE24 I 24
GE24 I 48
7.5V
9V
12V
15V
18V
24V
48V
0.5A
RATED CURRENT
3.0A
2.0A
2.22A
2.0A
1.6A
1.33A
1.0A
CURRENT RANGE
0 ~ 3.0A
0 ~ 2.0A
0 ~ 2.22A
0 ~ 2.0A
0 ~ 1.6A
0 ~ 1.33A
0 ~ 1.0A
0 ~ 0.5A
RATED POWER (max.)
15W
15W
20W
24W
24W
24W
24W
24W
RIPPLE & NOISE (max.) Note.3 50mVp-p
75mVp-p
100mVp-p
120mVp-p
150mVp-p
180mVp-p
240mVp-p
300mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
87%
87.5%
89%
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC
Note.7 90 ~ 264VAC
VOLTAGE RANGE
135 ~ 370VDC
FREQUENCY RANGE
INPUT
I I
GE24 I 05
Note.2 5V
I I
I I
SAFETY MODEL NO.
I I
I I
POWER SUPPLY MAIN BODY ORDER NO. GE24 I 05-P1J GE24 I 07-P1J GE24 I 09-P1J GE24 I 12-P1J GE24 I 15-P1J GE24 I 18-P1J GE24 I 24-P1J GE24 I 48-P1J
4000ms, 100ms, 10ms / 115VAC at full load
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
AC CURRENT
0.7A / 100VAC
INRUSH CURRENT (max.)
COLD START 40A / 100VAC
LEAKAGE CURRENT (max.)
0.25mA / 240VAC
110% ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVERLOAD
PROTECTION
83%
85.5%
86%
86%
0.4A / 230VAC
80A / 230VAC
OVER VOLTAGE
115% ~ 135% rated output voltage
Protection type : Clamp by zener diode
WORKING TEMP.
-10 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 30℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 8)
EMC EMISSION
EMC IMMUNITY
LIFE
OTHERS
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
2 years : 100% load 30℃, 8 hours / day
MIL-HDBK-217F (25℃)
MTBF
100Khrs min.
DIMENSION
PACKING
81*43*40.5mm (L*W*H)
134g ; 50pcs / 8.4kg / CARTON
DC OUTPUT PLUG
CONNECTOR CABLE
NOTE
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
File Name:GE24-SPEC 2015-09-15
GE24
24W AC-DC Interchangeable Industrial Adaptor
Mechanical Specification
series
36.5
40.5
Unit:mm
AWM2468 16AWG 1000±50mm for 5~9V
AWM2468 18AWG 1500±100mm for 12~48V
43
C"+"
11±0.5mm
ID 2.1 x OD 5.5
Outside
81
Inside
Plug Assignment
Standard plug: P1J
P1J
Derating Curve
P/N
OUTPUT
CENTER
+
Static Characteristics
100
90
LOAD (%)
LOAD (%)
100
75
50
80
70
60
50
40
-10
10
20
30
40
AMBIENT TEMPERATURE (℃)
50
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GE24-SPEC 2015-09-15