SGA60E series

60W AC-DC High Reliability Slim Wall-mounted Adaptor
(for 5V)
■ Features
Ultra slim
Universal AC input / Full range
2 pole EURO plug
No load power consumption< 0.075W for 5~7.5V
SGA60E
series
(for 9~48V)
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
<0.15W for 9 ~48V
Energy efficiency Level Ⅵ ( except 5V for Level Ⅴ)
Comply with EU ErP
Class Ⅱ power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
LED indicator for power on
3 years warranty
■ Description
SGA60E is a 60W ultra slim wall-mounted style single-output green adaptor series, which is compact and
convenient for carry. SGA60E is a class Ⅱ power unit (without FG) equipped with the standard 2-Pole
European plug, accepting the input range from 90VAC to 264VAC. The whole series provides different
models with output voltages ranging between 5VDC and 48VDC that it can satisfy the demands for various
types of consumer electronic devices.
With the efficiency up to 91% and the extremely low no-load power consumption below 0.075W for 5~7.5V,
below 0.15W for 9 ~48V, SGA60E is compliant with EU ErP. The supreme feature allows the adaptor to
save the energy when it is under either the operating mode or the standby mode. The entire series is approved
for international safety regulations; moreover, it adopts the 94V-0 flame retardant plastic case that it can
effectively prevent users from electric hazards.
■ Model Encoding
SGA 60 E 05 - P1J
{
P1J: Plug for standard model, 2.1ψ×5. 5ψ×11mm,
C+ tuning fork type
DC plug type
Optional plug type available per request
Output voltage
European 2 pin AC plug
Output wattage
Series name
File Name:SGA60E-SPEC 2015-05-05
60W AC-DC High Reliability Slim Wall-mounted Adaptor
SGA60E
series
SPECIFICATION
SGA60E05-P1J SGA60E07-P1J SGA60E09-P1J SGA60E12-P1J SGA60E15-P1J SGA60E18-P1J SGA60E24-P1J SGA60E48-P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
OUTPUT
SGA60E05
Note.2 5V
SGA60E07
SGA60E09
SGA60E12
SGA60E15
SGA60E18
SGA60E24
SGA60E48
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
6A
6A
5.5A
5A
4A
3.33A
2.5A
1.25A
CURRENT RANGE
0 ~ 6A
0 ~ 6A
0 ~ 5.5A
0 ~ 5A
0 ~ 4A
0 ~ 3.33A
0 ~ 2.5A
0 ~ 1.25A
RATED POWER (max.)
30W
60W
45W
49.5W
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.3 80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
100mVp-p
120mVp-p
VOLTAGE TOLERANCE Note.4 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
LINE REGULATION
Note.5 ±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
LOAD REGULATION
Note.6 ±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
88%
88%
91%
SETUP, RISE, HOLD UP TIME 500ms, 50ms, 12ms/230VAC
VOLTAGE RANGE
Note.7 90 ~ 264VAC
FREQUENCY RANGE
INPUT
84%
AC CURRENT
INRUSH CURRENT (max.)
1.5A / 115VAC
0.75A / 230VAC
40A / 115VAC
80A / 230VAC
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
OVERLOAD
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-20 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 8)
EMC EMISSION
EMC IMMUNITY
LIFE
CONNECTOR
NOTE
47 ~ 63Hz
EFFICIENCY (Typ.)
PROTECTION
OTHERS
500ms, 50ms, 12ms/115VAC at full load
86%
87%
88%
±0.03% / ℃ (0 ~ 40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
TUV EN60950-1 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3
Compliance to EN61000-4,-2,3,4,5,6,8,11, light industry level, criteria A
3 years : 100% load 40℃, 12hours / day
PACKING
PLUG
400Khrs min. MIL-HDBK-217F(25℃)
93.5*35*51.5mm (L*W*H)
250g ; 60pcs / 17kg / CARTON
See page 3 ; Other type available by customer requested
CABLE
See page 3 ; Other type available by customer requested
MTBF
DIMENSION
87%
1.All parameters are specified at 115VAC input, rated load, 25℃ 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:SGA60E-SPEC 2015-05-05
SGA60E
60W AC-DC High Reliability Slim Wall-mounted Adaptor
Derating Curve
series
Static Characteristics
100
90
LOAD (%)
LOAD (%)
100
70
80
70
60
50
40
-20
10
20
30
40
50
90
Ta (℃)
100
115
120
130
140
160
180
200
220
264
INPUT VOLTAGE
Mechanical Specification
Unit:mm
UL1571 14AWG 1000±50mm for 5~9V
UL1571 16AWG 1000±50mm for 12V
UL1185 16AWG 1000±50mm for 15~18V
UL1185 18AWG 1500±50mm for 24~48V
35
93.5
240
51.5
11±0.5mm
C"+"
ID 2.1 x OD 5.5
Outside
Inside
Plug Assignment
Standard plug: P1J
P1J
P/N
OUTPUT
CENTER
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:SGA60E-SPEC 2015-05-05