Fiber Driver® Chassis

Datasheet
Fiber Driver® Chassis
The Optical Multi-Service Platform
Hightlights
Models with 1, 2, 3, 4, or 16 slots
Flexible module hosting: no slot dependency
Hot-swap support
Management module support (except 1-slot models)
- component and link status monitoring
- command line and graphical administration
- SNMP support with status traps
Optional features on specific models (see ordering
tables)
- redundant power supplies (AC or DC pairs)
- no power supply (passive solutions)
- rack and wall mounting options
- front cable management tray
- blank slot covers
Overview
The Fiber Driver® chassis is the foundation for deploying and managing the Fiber Driver multi-service mixed-media
solutions. Chassis are available with one, two, three, four, and sixteen slots with power and mounting options depending
on the model. The smaller models may be wall-mounted, the larger modules include 19” rack mount hardware, and all
chassis can operate standalone on a tabletop mount.
Besides module capacity, each Fiber Driver chassis model has some varied features. One-slot and two-slot chassis include
an internal AC or DC power supply with power ratings to support all Fiber Driver modules.
Fiber Driver offering includes non-powered chassis. Some of these non-powered chassis have empty power supply
bays that support the optional redundant power supplies. (See ordering information tables.) Non-powered chassis are
designed to support passive networking solutions such as the Fiber Driver WDM modules in unmanaged applications.
A Fiber Driver Network Management module may be installed in any multi-slot chassis to monitor system component
parameters (temperature, fan status, and power supply) and network status. Some Fiber Driver devices may also be
actively managed to affect operational features and parameters. The management module provides secure local serial
access or remote Ethernet access to the entire Fiber Driver chassis system including the chassis itself to the modules and
even the individual ports.
Visit http://www.mrv.com or contact your nearest MRV representative for information on Fiber Driver or other
products.
1
Datasheet
Ordering Information
REDUNDANT POWER SUPPLIES
Model
Description
NC316-3RPSAC
Redundant power supply for NC316BU-3/AC
NC316-3RPSDC
Redundant power supply for NC316BU-3/DC
NC316BU-4SRPSAC
Redundant power supply for NC316BU-4S/AC
NC316BU-4SRPSDC
Redundant power supply for NC316BU-4S/DC
NC316-16RPSAC
Redundant power supply for NC316BU-16/AC
NC316-16RPSDC
Redundant power supply for NC316BU-16/DC
NC316BU-16/15RPSAC
Redundant power supply for NC316BU-16/15AC
NC316BU-16/15RPSDC
Redundant power supply for NC316BU-16/15DC
Ordering Information
ACCESSORIES
Model
Description
NC316MB-1
Wall mount bracket for NC316BU-1
NC316MB-2
Wall mount bracket for NC316BU-2
NC316RB23-3
Rack mount bracket for NC316BU-3/AC or -3/DC telco chassis; 23”
NC316-4SBRACKET
Rack mount bracket for 4-slot chassis; 19”
NC316RB23-4S
Rack mount bracket for NC316BU-4S/AC or -4S/DC telco chassis; 23”
NC316-16BRACKET
Rack mount bracket for 16-slot Chassis
NC316RB23-16
Rack mount bracket for NC316BU-16/AC chassis, 23”
NC316RB23-16/15
Rack mount bracket for NC316BU-16/15 chassis, 23”
NC316BP-1
Blank panel, single-slot wide, for NC316BU
NC316BP-4
Blank panel, four-slot wide, for NC316BU-16
NC316DCC
DC power female connector (WAGO)
NC316BU-16CMT
Cable management tray for the NC316BU-16 chassis
NC316MB-16
Wall mount bracket for NC316BU-16
NC316MB-16/15
Wall mount bracket for NC316BU-16/15 chassis
NC316RB23-16/15
Rack mount bracket for NC316BU-16/15 chassis; 23”
NC316-16DOOR
16BU chassis transponder protection door 19” rack mount
NC316-16/15BRKT
Rack Mount Bracket for NC316BU-16/15 chassis
NC316-16/15DOOR
16BU chassis transponder protection door 19” rack mount and cable management tray for use with
NC316BU-16/15 chassis
10900049-0001R
DC power cord for BU-16/15 chassis
Ordering Information
CHASSIS
Model
Description
Average Power
(Per Slot)
Physical Dimensions
(HxWxD)
Approx.
Weight
NC316BU-1/15AC
One-slot, AC power
15 watts
38 mm x 159 mm x 199 mm
(1.50” x 6.26” x 7.83”)
1.0 kg
(2.2 lbs)
NC316BU-1/15DC
One-slot, DC power
15 Watts
38 mm x 159 mm x 199 mm
(1.50” x 6.26” x 7.83”)
1.0 kg
(2.2 lbs)
NC316BU-1/15ACE
One-slot, AC power
(European version)
15 Watts
38 mm x 159 mm x 199 mm
(1.50” x 6.26” x 7.83”)
1.0 kg
(2.2 lbs)
NC316BU-1/15NP
One-slot, no power supply
(passive application only)
N/A
38 mm x 159 mm x 199 mm
(1.50” x 6.26” x 7.83”)
0.9 kg
(2.0 lbs)
2
Datasheet
CHASSIS (Continued)
Description
Average Power
(Per Slot)
Physical Dimensions
(HxWxD)
Weight
NC316BU-2/15AC
Two-slot, AC power
15 Watts
65 mm x 159 mm x 197 mm
(2.56” x 6.26” x 7.75”)
1.4 kg
(3.1 lbs)
NC316BU-2/15DC
Two-slot, DC power
15 Watts
65 mm x 159 mm x 197 mm
(2.56” x 6.26” x 7.75”)
1.4 kg
(3.1 lbs)
NC316BU-3/AC
Three-slot Telco, for 19” rack,
AC power
15 Watts
44 mm x 439 mm x 203 mm
(1.73” x 17.28” x 7.99”)
3.0 kg
(6.6 lbs)
NC316BU-3/DC
Three-slot Telco, for 19” rack,
DC power
15 Watts
44 mm x 439 mm x 203 mm
(1.73” x 17.28” x 7.99”)
3.0 kg
(6.6 lbs)
NC316BU-3V/AC
Three-slot, vertical stack, table
mount, AC power
15 Watts
103 mm x 202 mm x 217 mm
(4.05” x 7.95” x 8.54”)
2.5 kg
(5.5 lbs)
NC316BU-3V/DC
Three-slot, vertical stack, table
mount DC power
15 Watts
103 mm x 202 mm x 217 mm
(4.05” x 7.95” x 8.54”)
2.5 kg
(5.5 lbs)
NC316BU-4S/AC
Four-slot, for 19” rack,
AC power
15 Watts
44 mm x 439 mm x 305 mm
(1.73” x 17.28” x 12.00”)
4.5 kg
(9.9 lbs)
NC316BU-4S/DC
Four-slot, for 19” rack,
DC power
15 Watts
44 mm x 439 mm x 305 mm
(1.73” x 17.28” x 12.00”)
4.5 kg
(9.9 lbs)
NC316BU-4S/NP
Four-slot, two empty power
supply bays
N/A
44 mm x 439 mm x 305 mm
(1.73” x 17.28” x 12.00”)
4.0 kg
(8.8 lbs)
Non-managed, non-powered
four-slot chassis for passive
Mux/Demux modules
N/A
44 mm x 441 mm x 286 mm
(1.73” x 17.36” x 11.26”)
4.5 kg
(9.9 lbs)
NC316BU-16/AC
Sixteen-slot, for 19” rack,
AC power
10 Watts
110 mm x 439 mm x 408 mm
(4.33” x 17.28” x 16.06”)
8.8 kg
(19.4 lbs)
NC316BU-16/DC
Sixteen-slot, for 19” rack,
DC power
10 Watts
110 mm x 439 mm x 408 mm
(4.33” x 17.28” x 16.06”)
8.7 kg
(19.2 lbs)
NC316BU-16/NP
Sixteen-slot, for 19” rack,
two empty power bays
N/A
(10-Watt option)
110 mm x 439 mm x 408 mm
(4.33” x 17.28” x 16.06”)
7 kg
(15.4 lbs)
NC316BU-16/15AC
Sixteen-slot, for 19” rack,
AC power
15 Watts
132 mm x 439 mm x 359 mm
(5.2” x 17.28” x 14.13”)
9.7 kg
(21.4 lbs)
NC316BU-16/15DC
Sixteen-slot, for 19” rack,
DC power
15 Watts
132 mm x 439 mm x 359 mm
(5.2” x 17.28” x 14.13”)
9.4 kg
(20.7 lbs)
NC316BU-16/15NP
Sixteen-slot, for 19” rack,
two empty power bays
N/A
(15-Watt option)
132 mm x 439 mm x 359 mm
(5.2” x 17.28” x 14.13”)
7.2 kg
(15.8 lbs)
Ordering Information
Model
NC316BU4PMC/NP
Power Supply Specifications
Nominal Input
Range (VAC)
Input Range
(VDC)*
Nameplate
Rating (Amps)
Operating
Temperature
Storage
Temperature
Relative
Humidity
NC316BU-1/15AC
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-1/15DC
-
- 40.5 to - 57
0.5
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-1/15ACE
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
Model
* Compliant with ANSI T1.315-2001 (R 2006) standard
3
Datasheet
Power Supply Specifications (Continued)
Nominal Input
Range (VAC)
Input Range
(VDC)*
Nameplate
Rating (Amps)
Operating
Temperature
Storage
Temperature
Relative
Humidity
NC316BU-2/15AC
100 - 240 @ 50/60 Hz
-
0.4
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-2/15DC
-
- 40.5 to - 57
0.8
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-3RPSAC
100 - 240 @ 50/60 Hz
-
1.6
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-3RPSDC
-
- 40.5 to - 57
2.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-4SRPSAC
100 - 240 @ 50/60 Hz
-
1.8
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-4SRPSDC
-
- 40.5 to - 57
2.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-16RPSAC
100 - 240 @ 50/60 Hz
-
2.0
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-16RPSDC
-
- 40.5 to - 57
5.0 or 6.5
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-16/15RPSAC
100 - 240 @ 50/60 Hz
-
3.7
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-16/15RPSDC
-
- 40.5 to - 57
7.5
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
Model
* Compliant with ANSI T1.315-2001 (R 2006) standard
Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV CUE
Mark (Canada, USA, EU); GOST (selected products); RoHS Directive, WEEE Directive: Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick (selected products).
Contact your sales representative for details.
MRV has more than 50 offices throughout the world. Addresses, phone numbers and fax numbers are listed at www.mrv.com.
Please e-mail us at [email protected] or call us for assistance.
MRV Los Angeles
MRV Boston
20415 Nordhoff Street
300 Apollo Drive
Chatsworth, CA 91311
Chelmsford, MA 01824
800-338-5316
800-338-5316
818-773-0900
978-674-6800
MRV International
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax (49) 6105/207-100
All statements, technical information, and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
MRV-FD-CHASS-091611
1398005-001 Rev. D4
Copyright ©2011 MRV Communications, Inc. All Rights Reserved.