PBSP 740 Series

PBSP 740 Series
Features
•
•
•
•
•
High surge rating of 12kW.
Halogen free low smoke Radox cabling.
Earth leakage breaker on output.
Strengthened against shock & vibration.
Input spike & burst protection.
SPECIFICATIONS
STANDARDS
INPUT
C-Tick
Voltage
60-84Vdc
Current
40mA standby, 60A (74Vdc input), 160A max.
Under voltage cut-out
59Vdc.
Under voltage re-set
71Vdc.
Over voltage cut-out
90Vdc.
Over voltage re-set
87Vdc.
Input protection
100A, AS3111, 10kA MCB
OUTPUT
Voltage
240Vac ±5%
Frequency
50Hz ±1%
Total harmonic distortion
3%
Output power
4kW continuous.
Surge power
5kW, 30min; 12kW, 3sec.
MECHANICAL
Dimensions
490x300x235mm
Weight
38kgs.
Enclosure
Powder coated aluminium chassis.
Wiring
All internal wiring uses Radox 125 halogen
free low smoke cable.
Mounting
Suitable for vertical or horizontal mounting.
DC input connector
MS3102 R28-22P F80 six crimp pin chassis
receptacle.
MS3108 E28-22SF80 right angle six crimp
socket plug with strain relief. Supplied with
unit
DC mating connector
Output overload and short Automatic shutdown, auto restart after 60
circuit protection
secs.
Output protection
Via 20A MCB / RCD as per AS3111 /
AS3190.Output neutral connected to inverter
chassis earth on inverter side of MCB / RCD.
Over temperature
Shutdown, auto-restart.
protection
OPERATING
Efficiency
90%–95% load dependent.
Isolation
Input – Output: 4250VAC
Input – Ground: 1700VAC
Output – Ground: 2250VAC
Designed to meet AS/NZS CISPR11:
/EN50121-3-2 limits
RAILWAY CONVERTERS
7 2 V D C , 4 0 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R
OUTPUT CONNECTOR (PBSP-740-D VARIANT)
AC output connector
AC mating connector
MS3102 R1810S F80. Four crimp socket
chassis receptacle.
MS3106 R1810P F80. Four crimp pin plug with
strain relief supplied with the unit.
OUTPUT CONNECTOR (PBSP-740-G VARIANT)
AC output connector
Terminations
Three Wilco WIBM110-LE
Single phase 10A 3 flat IP56 insulated socket
outlets.
ENVIRONMENTAL
Operating temperature
Cooling
0°C to 50°C ambient. Derate to 65°C at
reduced duty cycle.
Internal thermostatically controlled fan.
Shock
4G ±20% longitudinally
Vibration
Resonant search:
20-2.2mm double amplitude (1-9Hz)
2.2-0.8mm double amplitude (10-50Hz)
Endurance:
3 hours per axis (X,Y,Z) at 50Hz 0.8mm double
amplitude.
Relative Humidity
95% non-condensing
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
475
RAILWAY CONVERTERS
PBSP 740 Series
7 2 V D C , 4 0 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R S
D - VARIANT
G - VARIANT
476