COA - Power Mate Technology Co., LTD

Issue Date:
2007-11-12
Page 1 of 11
Report Reference #
E193009-A15-UL
2013-03-04
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
Product:
Model:
Rating:
Applicant Name and Address:
UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Component Recognition
QQGQ2, QQGQ8 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
DC-DC Converter
FEC15-xyzWaaaaaaaa, FED20-xyzWaaaaaaaa (x= 24 or 48; y= S or
D; z= 3P3, 05, 12, 15, 05P1; a may be any alphanumeric character, "-"
or blank for marketing purpose and no impact safety related critical
components and constructions.) And
DFEC15-XbcWz1z1z1z1z1z1, UFEC15-XbcWz1z1z1z1z1z1,
DFED20-XbcWz1z1z1z1z1z1, UFED20-XbcWz1z1z1z1z1z1, where
"X" can be 24 or 48;
"b" can be S or D;
"c" can be 3P3, 05, 5P1, 12 or 15;
"z1" can be any alphanumeric or blank. For marketing purpose only
and no impact safety related constructions and critical component
See Miscellaneous for details.
POWER MATE TECHNOLOGY CO LTD
36 22ND RD
TAICHUNG INDUSTRIAL PARK
TAICHUNG
408 TAIWAN
Copyright © 2013
Issue Date:
2007-11-12
Page 2 of 11
Report Reference #
E193009-A15-UL
2013-03-04
Engineering Conditions of Acceptability
For use only in or with complete equipment where the acceptability of the combination is determined by UL
LLC. When installed in an end-product, consideration must be given to the following:
The end-product Electric Strength Test is to be based upon a maximum working voltage of: 172 Vpk,
36.2 Vrms(Model FED20-48D15W).,
The following secondary output circuits are SELV: All outputs
The following secondary output circuits are at non-hazardous energy levels: All outputs.
The following output terminals were referenced to earth during performance testing: T1, pin 7, 6
The power supply terminals and/or connectors are: Suitable for factory wiring only
The investigated Pollution Degree is: 2
The following end-product enclosures are required: Electrical, Fire, Mechanical
The component is considered as functional insulation and intended to be installed in an isolated
secondary circuit which is separated from primary circuit by Reinforce or Double insulation, additional
tests of Humidity Test should be considered in the host product.
The units were tested for an input voltage of 9 to 36 Vdc and 18 to 75 Vdc with no tolerance. If used
outside this voltage range, additional testing may be required.
All circuit was evaluated as secondary hazadous voltage level with Functional Insulation, and it is
necessary that Basic Insulation shall be considerated in the investigation of host product.
The following output terminals were referenced to earth during performance testing: T1, pin 7, 6