Issue Date: 2007-11-12 Page 1 of 11 Report Reference # E193009-A15-UL 2013-03-04 UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: Applicant Name and Address: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) DC-DC Converter FEC15-xyzWaaaaaaaa, FED20-xyzWaaaaaaaa (x= 24 or 48; y= S or D; z= 3P3, 05, 12, 15, 05P1; a may be any alphanumeric character, "-" or blank for marketing purpose and no impact safety related critical components and constructions.) And DFEC15-XbcWz1z1z1z1z1z1, UFEC15-XbcWz1z1z1z1z1z1, DFED20-XbcWz1z1z1z1z1z1, UFED20-XbcWz1z1z1z1z1z1, where "X" can be 24 or 48; "b" can be S or D; "c" can be 3P3, 05, 5P1, 12 or 15; "z1" can be any alphanumeric or blank. For marketing purpose only and no impact safety related constructions and critical component See Miscellaneous for details. POWER MATE TECHNOLOGY CO LTD 36 22ND RD TAICHUNG INDUSTRIAL PARK TAICHUNG 408 TAIWAN Copyright © 2013 Issue Date: 2007-11-12 Page 2 of 11 Report Reference # E193009-A15-UL 2013-03-04 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The end-product Electric Strength Test is to be based upon a maximum working voltage of: 172 Vpk, 36.2 Vrms(Model FED20-48D15W)., The following secondary output circuits are SELV: All outputs The following secondary output circuits are at non-hazardous energy levels: All outputs. The following output terminals were referenced to earth during performance testing: T1, pin 7, 6 The power supply terminals and/or connectors are: Suitable for factory wiring only The investigated Pollution Degree is: 2 The following end-product enclosures are required: Electrical, Fire, Mechanical The component is considered as functional insulation and intended to be installed in an isolated secondary circuit which is separated from primary circuit by Reinforce or Double insulation, additional tests of Humidity Test should be considered in the host product. The units were tested for an input voltage of 9 to 36 Vdc and 18 to 75 Vdc with no tolerance. If used outside this voltage range, additional testing may be required. All circuit was evaluated as secondary hazadous voltage level with Functional Insulation, and it is necessary that Basic Insulation shall be considerated in the investigation of host product. The following output terminals were referenced to earth during performance testing: T1, pin 7, 6