PTRH-T Data Sheet.pub

 30 Amp Power PCB Relay
PTRH-T
FEATURES








CONTACT DATA
E86876 General Purpose
1 Form C
1 Form A 1 Form B
Voltage
(SPST-NO) (SPDT-NC)
NO
NC
120 VAC
30 A
20 A
30 A
20 A
250 VAC
30 A
20 A
30 A
20 A
Load Type
30 VDC
Most Popular Power PCB Relay Footprint - T90
30 Amp 250 VAC General Purpose UL Rating
2 HP 250 VAC Rating
UL Class F Insulation Standard
Gold Flashed Contacts Available
Meets UL 508 and UL 873 Spacing
Epoxy Sealed, Immersion Cleanable
RoHS Compliant
30 A
120 VAC
30 A
Resistive
(100.000 Cycles) 250 VAC
30 A
240 VAC
2 HP
Motor
(30,000 Cycles) 120 VAC
1 HP
240 VAC 80 A/30 A
LRA/FLA
120 VAC 96 A/30 A
20 A
30 A
20 A
20 A
20 A
30 A
30 A
20 A
20 A
—— —— —— —— 2 HP
1 HP
80 A/30
96 A/30
—— —— —— —— Material
Initial Contact Resistance
Maximum Switching Voltage
Maximum Switching Current
Maximum Switching Power
Mechanical
Service Life
Electrical
AgSnO2, AgSnO2
50 MΩ Max. @ 1 A, 6 VDC
110 VDC, 300 VAC
30 A
1,500 W, 12,000 VA
1 X 107 Operations
5 X 104 Operations
Meets UL 508 and UL 873 Spacing ‐ 3.18 mm Through Air, 6.36 mm Over Surface. CHARACTERISTIC Continued
CHARACTERISTIC
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Power Consumption
Less than 15 ms
Less than 10 ms
1,000 MΩ min, at 500 VDC, 50% RH
50 Hz 2,500 V 1 Min Between Coil and Contacts
4,000 V without Pin 6
50 Hz 1,500 V 1 min. Between Contacts
200 m/s, 11 ms
0.9 W, 0.6 W
Vibration Resistance
Terminal Strength
Solderability
Operating Temperature Range
10 - 55 Hz Double Amplitude
Storage Temperature Range
- 40°C to 155°C
Relative Humidity
Weight
Material Compliant To
85% (at 40°C)
ORDERING INFORMATION
Example:
PTRH
-1C
-12
S
Model: PTRH (PTRH-T)
Contact Form: 1A, 1B, 1C
Coil Voltage: 3, 5, 6, 9, 12, 15, 24, 48, 110
Enclosure: S: Sealed; E: Covered C: Dust Cover
Package Height: Nil: Standard: L: Low Profile (Terminals Exposed)
Coil Sensitivity: Nil: 0.9 W; 0.6: 0.6 W;
Contact Material: Nil: AgCdO; T: AgSnO2
Mounting Type: T2: Form 1A PCB & QC; T3; Form 1C PCB & QC:
T4: 1A Panel all QC; T5: 1 CPanel all QC
RoHS Compliant: -X
Box Quantity: 600; Inner Box 300
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PTRH-T Rev E 5/21/15
-T5
10N
235 ºC for 3 secs
- 40°C to 125°C
13.5 gr Approximately
EU RoHS V2, EU REACH V3
-X
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
1 of 2
PTRH-T
PTRH-T
COIL DATA Coil Voltage
Coil Power (W)
Resistance (Ohms ± 10%)
Must Release
Coil Power (W)
Must Operate Voltage Max (VDC)
Rated
Max
0.6 W
0.9 W
1.1 W
0.6 W & 0.9 W
1.1 W
3
5
6
9
12
15
18
24
28
48
110
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
36.4
62.4
143
15
42
60
135
240
375
540
960
1307
3840
20167
10
28
40
90
150
260
380
640
871
2560
13445
————33
——131
————524
713
2095
——-
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
21.0
36.00
82.50
————4.8
——9.6
————19.2
22.4
38.4
——-
Voltage Min
(VDC)
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
2.8
4.8
11.0
NOTES:
The use of any coil voltage less that the rated voltage will compromise the operation of the relays. Must Operate Voltage is listed for test purposes only and is
not to be used as design criteria. Pickup and release voltages are for test purposes only and are not to be used as design criteria.
Dimensions are in mm, Inches are listed for reference only.
DIMENSIONS (mm/inches)
Knock off, on top corner, nib for ventilation after soldering and water wash. T4 & T5 T2 & T3 Wiring Diagram (Top View) Wiring Diagram (Bo om View) 5 mm SPDT 12 Amp Wiring Diagram (Top View) 3.5 mm SPDT 12 Amp Moun ng (Bo om View) 3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272
(888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PTRH-T Rev E 5/21/15
www.PickerComponents.com
e-mail: [email protected]
Specifications and Availability subject to change without notice.
2 of 2