AC Output Solid State Relay Horizontal PCS32 AC Output FEATURES Vertical Small Dimension for High Packing Density PCB Assembly or Socket Mount 2,500 VRMS Opto-Isolation Between Input and Output TTL and CMOS compatible For Interface Application Between PLC and External Loads RoHS Compliant E93379 INPUT PARAMETERS (Ta = 25°C) Control Voltage Range Must Turn-On Voltage Zero Cross turn-on Must Turn-Off Voltage OUTPUT PARAMETERS (Ta = 25°C) 5D 4 - 6 VDC 12D 24D 60D 5D 12D 24D 60D 9.6 - 14.4 VDC 19.2 - 28.8 VDC 48 - 72 VDC 4 - 6 VDC 9.6 - 14.4 VDC 19.2 - 28.8 VDC 48 - 72 VDC 5D 1 VDC 12D 3 VDC 24D 10 VDC 60D 20 VDC Random Turn-On Max. Input Current Max. Reverse Protection Voltage Load Voltage Range Max. Transient Voltage Load Current Range Insulation Resistance Max. On-State Voltage Drop 0.1 A to 2 A 30 A 80 A 1.2 VRMS A1 4.5 A2 32 1/2 Cycles + 1 ms Max. I2t (10 ms, A2s) Max. Turn-On Time 1 ms Max. Turn-Off Time 1/2 Cycles + 1 ms 1 VDC Frequency Range 47 Hz to 63 Hz 25 mA Min. Off-State dv/dt 100 V/us 5D -6 VDC 12D -14.4 VDC 24D -28.8 VDC 60D -72 VDC Max. Off-State Leakage Current 1 mA CHARACTERISTICS Continued 2,500 VAC, 1 min. Input to Output Max. Capacitance 2 Amp 1 Amp 2 Amp Max. Surge Current (10 ms) CHARACTERISTICS Dielectric Strength 48 VAC to 280 VAC 600 Vpk 1 Amp 0.1 A to 1 A Vibration Resistance 10 Hz - 55 Hz 1.5 mmm DA Shock Resistance Acceleration 980 m/s2, Continuous Surge 6 ms Operating Temperature -30°C to 80°C Storage Temperature -30°C to 100°C 1,000 MΩ at 500 VDC Relative Humidity 5 pF (Input to Output) Weight 45% - 85% 11 g (Horizontal), 4g (Vertical) ORDERING INFORMATION Example: PCS32 Model: PCS32 AC Output Control Voltage: 5D: 5 VDC; 12D: 12 VDC; 24D: 24 VDC; 60D: 60 VDC Load Voltage: 240A: 240 VAC Load Current: 1: 1 A; 2: 2 A -12D -240A -2 Z Notes: *Varistor Version (Y) available only in 1 Amp, Zero Crossing Switching Type: Z: Zero Crossing; R: Random Turn-On Overvoltage Protection: Nil: Without; Y*: With Varistor Mounting Mode: Nil: Vertical (PC Pins In Line); H: Horizontal (PC Pins Dual In Line) Vertical Box Quantity: 2,000; Inner Box 100, Horizontal Box Quantity: 500; Inner Box: 50 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS32 AC Output Rev B 9/16/2015 **Horizontal Version (H) available only in 2 Amp Version www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 1 of 3 PCS32 AC Output PCS32 AC Output PRECAUTIONS 1. Soldering must be completed within 10s at 260 or less or within 5s at 350 or less. 2. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, the load current must be reduced. Please refer to the curve of Max. Load current Vs. Ambient Temperature. 3. If the output transient voltage exceeds the nominal value, a varistor should be mounted on the SSR output terminal in parallel to prevent the relay being breakdown. 240VAC output relays are suggested to use 470 VDC varistors. 4. Please do not use the relay beyond the descriptions in the datasheet. DIMENSIONS (mm) 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS32 AC Output Rev B 9/16/2015 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 2 of 3 PCS32 AC Output PCS32 AC Output CHARACTERISTIC CURVES 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS32 AC Output Rev B 9/16/2015 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 3 of 3