AC Output Solid State Relay PCS27 AC Output FEATURES 2 A or 3 A Output DC Input: 5 VDC; 12 VAC; 24 VAC PCB Mount Built in Snubber Photoelectric Isolation RoHS Compliant E93397 INPUT PARAMETERS (Ta = 25°C) 5 12 24 5 12 24 Control Voltage Range Must Turn-On Voltage OUTPUT PARAMETERS (Ta = 25°C) 4 - 6 VDC 9.6 - 14.4 VDC 19.2 - 28.8 VDC 4 VAC 9.6 VAC 19.2 VAC 2,240 2, 380 2,240 3,380 Load Voltage Range 48-280 VAC 48-440 VAC 48-280 VAC 48-440 VAC Max. Transient Voltage Load Current Range Max. Surge Current (10 ms) 600 Vpk 800 Vpk 600 Vpk 800 Vpk 0.1 - 2 A 0.1 - 3 A 60 Apk 80 Apk 25 mA Max. I2t (10 ms, A2s) 5 250 Ω Max. On-State Voltage Drop 12 720 Ω Max. Off-State Leakage Current 24 1.64 kΩ Min. Off-State dv/dt 200 V/us 1 VDC Max. Turn-On Time Zero Cross: 1/2 Cycles + 1 ms; Random: 1 ms Max. Turn-Off Time 1/2 Cycles + 1 ms Frequency Range 47 - 63 Hz Min. Power Factor 0.5 Max. Input Current Input Resistance Amperage, Voltage Must Turn-Off Voltage 18 32 1.5 VRMS 5 mA CHARACTERISTICS Dielectric Strength 4,000 VAC, 50 Hz/60 Hz, 1 min. (Input to Output) Operating Temperture - 30°C to 80°C Insulation Resistance 1,000 MΩ at 500 VDC (Input to Output) Storage Temperature - 30°C to 100°C Relative Humidity Max. Capacitance 8 pF (Input to Output) Shock Resistance Acceleration 980 m/s2, Continuous Surge 6 ms Vibration Resistance Weight 45% - 85% Approximately 70 g 10 Hz - 55 Hz 1.5 mmm DA ORDERING INFORMATION Example: PCS27 Model: PCS27 AC Output ‐12D ‐240A ‐2 Z Control Voltage: 5D: 4‐6 VDC 12D: 9.6 ‐ 14.4 VDC, 24D: 19.2 ‐ 28.8 VDC Load Voltage: 240A: 240VAC, 380A: 380 VAC Load Current: 2: 2 Amp, 3: 3 Amp Switching Type: Z: Zero Crossing, R: Random Turn‐On Box Quantity: 540; Inner Box 27 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS27 AC Output Rev A 8/4/15 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 1 of 2 PCS27 AC Output PCS27 AC Output PRECAUTIONS 1. 2. 3. 4. 5. Maximum Soldering Temperatures: 260°C for a maximum of 10 seconds or 350°C for a maximum of 5 seconds. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, the load current must be reduced. Please refer to the curve of "Max. Load current Vs. Ambient Temperature". The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sure that the polarity and the input and output are correct when connecting. If the output transient voltage exceeds the nominal value a varistor should be mounted on the SSR output terminals in parallel to prevent a breakdown of the triac output junction. The result could be a permanent short of the output. The recommended varistor voltage 470V. When using the relay in phase control applications, at a phase control angle close to 180 degrees the relay's input signal will turn off at the trailing edge of the AC sine wave. The phase delay must be limited to end 200us before AC zero cross. This assures that the relay has time to switch off. Shorter times may cause loss of control at the following half cycle. DIMENSIONS (mm) CHARACTERISTIC CURVES 3220 Commander Drive, Suite 102 Carrollton, TX 75006 Sales: (972) 713-6272 (888) 997-3933 Fax: (972)735-0964 Dimensions are listed for reference purposes only. PCS27 AC Output Rev A 8/4/15 www.PickerComponents.com e-mail: [email protected] Specifications and Availability subject to change without notice. 2 of 2