TSD-1185 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
FIGURE 1: SCHEMATIC DIAGRAM
SWITCHING TRANSFORMER DESIGNED FOR USE WITH POWER INTEGRATIONS
TOP221P (RD7 DEMO BOARD TRANSFORMER TRD1), REFER TO APPLICATION
CIRCUIT OF FIGURE 3.
PARAMETER
MIN.
PRIMARY INDUCTANCE (2-1)
FREQ. = 100 KHZ @ 0.250Vrms
2.19
SPEC LIMITS
TYP.
MAX.
2.43
2.67
DOT ON BOBBIN
DENOTES PIN #1
1
UNITS
mHY
PRIMARY
9, 10
2
TURN RATIO'S:
SECONDARY (9-6) : PRIMARY (2-1)
BIAS (4-3) : PRIMARY (2-1)
---------------
PRI LEAKAGE IND. (5-10 SHORTED)
FREQ. = 100 KHZ @ 0.250Vrms
--------
1: 19.33
1: 8.29
---------------
--------
70
+ 4%
+ 4%
SECONDARY
3
6, 7
BIAS
µHY
4
HIPOT:
PRIMARY TO SECONDARY
BIAS TO SECONDARY
3000
3000
---------------
---------------
Vrms
Vrms
APP CIRCUIT PARAMETERS: (1)
DC HOT RAIL VOLTAGE
OUTPUT VOLTAGE
OUTPUT CURRENT CONTINUOUS
OUTPUT CURRENT PEAK
LINE REGULATION (90 TO 375Vdc)
LOAD REGULATION 10-100%
RIPPLE
90
-------50
-----------------------------
-------5.0
--------------1.0
1.0
50
375
-------700
800
----------------------
Vdc
Vdc
mA
mA
+%
+%
+mV
NOTE1:
REINFORCED INSULATION SYSTEM, UL1950, IEC950, CSA-950:
A) ALL MATERIALS MEET "UL", "CSA" & "IEC" REQUIREMENTS
B) TRIPLE BASIC INSULATED SECONDARY.
C) DESIGNED TO MEET >6.2mm CREEPAGE REQUIREMENTS.
D) VARNISH FINISHED ASSEMBLY.
E) UL CLASS (B) 130 INSULATION SYSTEM PM130-R1,
PM130-H1, PM130-H1A (UL FILE #E177139) OR ANY UL
AUTHORIZED CLASS (B) INSULATION SYSTEM.
(1) REFER TO GENERAL APPLICATION CIRCUIT OF FIGURE 3.
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
10
9
P
M
PIN #1
WHITE DOT
1
8
7
6
5
TSD-1185
YYWW
2
3
4
18.2
(.716)
MAX
16.5
(.650)
MAX
3.5
(.138)
UL INSULATION
SYMBOL AND
MANUFACTURER
IDENTIFICATION
HERE
17.6
(.693)
MAX
1
10.5
(.413)
2
3
4
12.5
(.492)
6.0
(.236)
TYP
4.5
(.177)
TYP
0.6 DIA.
(.024)
12.2
(.480)
REV.
04/08/98
08/24/98
01/04/99
08/13/99
10
9
8
2.7
(.106)
7
6
5
13.5
(.531)
DESCRIPTION OF CHANGES
ORIGINAL RELEASE
CLARIFY APPLICATION NOTE
CORRECT PRI INDUCTANCE PER CUSTOMER DRAWING
UPDATE TO UL CLASS (B) 130 INSULATION SYSTEM
EE16/EI16, 10-PIN VERTICAL
P Premier
M Magnetics Inc.
"INNOVATORS IN MAGNETICS TECHNOLOGY"
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
FLYBACK TRANSFORMER CONTROL DRAWING
PREMIER P/N: TSD-1185
REVISION: 08/13/99
ENGR: AL SANTOS
REF: TOP221P
APPD: TOM O'NEIL
SHEET: 1 OF 6
BY
AS
PP
PP
MD
APPLICATION NOTES
Premier Magnetics' TSD-1185 Switch Mode Transformer was designed for use with Power Integrations, Inc. PWRTOP221P three terminal off-line PWM switching regulator in the Flyback Buck-Boost circuit configuration. This
conversion topology can provide isolated multiple outputs with efficiencies up to 90%. Premiers' TSD-1185
transformer has been optimized to provide maximum power throughput.
The TOPSwitch-II series from Power Integrations, Inc. are self contained 100KHz three terminal voltage
controlled PWM switching regulators. This series contains all necessary functions for an off-line switched mode
control DC power source. These switching regulators provide a very simple solution to off-line designs. The
inductors and transformer used with the TOPXXX are critical to the performance of the circuit. They define the
overall efficiency, output power and overall physical size.
Below is a universal input high precision 3.5 watt application circuit utilizing Power Integrations TOP221P
switching regulator in the flyback buck-boost configuration. The component values listed are intended for
reference purposes only. Please refer to Power Integrations application notes for the RD7 demo board for more
information.
FIGURE 3: TOP221P TYPICAL APPLICATION CIRCUIT
Fuse Resistor
+
C1
10nF
1Kv
+
RF1
1 Ohm
HOT RAIL
+90 to 375Vdc`
RTN
C2
+
2.2nF
1KV
R1
47K
1/2W
1
D1
UF4005
2
BIAS
C6
0.1uF
D2
1N4148
U2
SFH615-2
3
DRAIN
D
C
N/C
N/C
N/C
N/C
S
1/2 OF U2
+
VR1
1N5228B
SEC
Css
C4
+
100uF
25V
RTN
6,7
1
A 1/2 OF U2
4
C
U1
POWER INT.
PWR-TOP221P
+5Vdc
@ 700mA
C3
+
270uF
25V
T1
TSD-1084
4
L1
3.3uH
D2
1N5822
9,10
PRI
C
2
R2
10
R3
100
E
CONTROL
+
Cc
0.1uF
C5
470uF
10V
S
SOURCE
HIGH VOLTAGE RETURN
P Premier
M Magnetics Inc.
"INNOVATORS IN MAGNETICS TECHNOLOGY"
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MM
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DO NOT SCALE DRAWING
FLYBACK TRANSFORMER CONTROL DRAWING
PREMIER P/N: TSD-1185
REVISION: 08/13/99
ENGR: AL SANTOS
REF: TOP221P
APPD: TOM O'NEIL
SHEET: 2 OF 6