100 Series HWT Output Inductors

TM
HWT
100 Series
Output Inductors
• Energy Storage Capacity: 3.4-5 mJ
Specifications
MIX 8 G0
MIX 52 G2
MIX 52 G1
MIX 52 G0
SCHOTT
P/N
L, µH
0 ADC
SCHOTT
P/N
L, µH
0 ADC
SCHOTT
P/N
L, µH
0 ADC
SCHOTT
P/N
L, µH
0 ADC
RATED
CURRENT
AMPS DC
DCR
mOHM
REF
# COILS
32521
1.0
32539
1.02
32557
1.35
32575
2.12
92.5
0.43
3
32522
4.44
32540
1.47
32558
1.94
32576
3.06
75.8
0.61
3
32523
1.97
32541
2.0
32559
2.64
32577
4.16
66.9
7.75
2
32524
2.57
32542
2.61
32560
3.44
32578
5.43
58.6
0.95
2
32525
3.25
32543
3.3
32561
4.36
32579
6.88
51.6
1.2
2
32526
4.01
32544
4.08
32562
5.38
32580
8.49
45.8
1.5
2
32527
4.85
32545
4.94
32563
6.51
32581
10.3
41.1
1.8
2
32528
5.78
32546
5.88
32564
7.75
32582
12.2
37.2
2.2
2
32529
7.86
32547
8.0
32565
10.5
32583
16.6
33.8
2.6
1
32530
9.03
32548
9.18
32566
12.1
32584
19.1
31.7
2.9
1
32531
10.3
32549
10.4
32567
13.8
32585
21.7
29.8
3.3
1
32532
13.0
32550
13.2
32568
13.2
32586
27.5
26.2
4.2
1
32533
16.0
32551
16.3
32569
21.5
32587
34.0
23.3
5.2
1
32534
19.4
32552
19.7
32570
26.0
32588
41.1
20.9
6.5
1
32535
23.1
32553
23.5
32571
31.0
32589
48.9
18.9
7.8
1
32536
27.1
32554
27.6
32572
36.4
32590
57.4
17.2
9.4
1
32537
31.5
32555
32.0
32573
42.2
32591
66.5
15.8
11.2
1
32538
36.1
32556
36.7
32574
48.4
32592
76.4
14.5
13.1
1
Parts availability subject to Schott manufacturing schedules and leadtimes. Not all parts available from stock.
Please contact us for more details and availability. The Adobe Acrobat Reader is required to view these linked documents.
Electrical Specifications Test Criteria
1. Inductance tolerances at zero DC current are ±10% for G2 designs, ± 12% for G0 and G1 designs.
2. Inductances shown are at zero DC current. See inductance vs. bias curves for inductances with DC current.
3. Temperature rise is approximately 60°C at rated DC current.
4. Multiple coil units are rated with all coils parallel connected.
5. Parts are 100% tested for inductance and hipot (1000 Vrms).
All data is believed to be accurate at time of printing. Schott Corporation reserves the right to make changes without notification.
“Schott” is a trade name of Schott Corporation. All other trademarks and trade names are the property of their respective holder.
© 2001 Schott Corporation
1000 Parkers Lake Road, Wayzata, Minnesota 55391 U.S.A.
Tel: + (952) 475-1173
Fax: + (952) 475-1786
Email: [email protected]
Web: http://www.schottcorp.com
Standard Configuration
150 SERIES
SERIES
100
INDUCTANCE vs DC CURRENT
TYPICAL
100
Percent of Zero DC Inductance
80
1
2
60
3
40
1 - MIX 52 GAP-G2
2 - MIX 8 GAP-G0
3 - MIX 52 GAP-G1
4 - MIX 52 GAP-G0
4
20
0
0
20
40
60
80
100
120
140
160
180
200
Percent of Rated Current
.80
MAX
2.00
MIN
.19 REF
1.06
MAX
.66 REF
1.06
MAX
.78 REF
All statements and technical information contained herein are believed to be accurate, but the accuracy and completeness thereof is not guaranteed.
If any product is found to be defective, Schott Corporation’s (Seller) only obligation shall be to replace such quantity of the product proved to be
defective. User shall determine the suitability of the product for the intended use, and user assumes all risk and liability whatsoever in connection
herewith. Seller shall not be liable for any direct, consequential, or incidental loss or damage. Conditions not specifically stated herein shall be
governed by established trade customs. Schott Corporation reserves the right to makes changes without notification. “Schott” is a trade name of
Schott Corporation. All other trademarks and trade names are the property of their respective holder.
©2001 Schott Corporation
Schott Corporation
1000 Parkers Lake Road
Wayzata, Minnesota 55391
U.S.A.
Tel: + (952) 475-1173
Fax: + (952) 475-1786
Email: [email protected]