GAS GENERATOR SET MTU 10V0183 GS350 350 kWe /60 Hz /Standby 208 - 600V Reference MTU 10V0183 GS350 (300 kWe) for Prime Rating Technical Data SYSTEM RATINGS Standby Voltage (L-L) Phase PF Hz Natural Gas Ratings: Amps Natural Gas Ratings: kW/kVA LP Gas Ratings: Amps LP Gas Ratings: kW/kVA skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1 60 208V** 3 0.8 60 240V** 3 0.8 60 480V** 3 0.8 60 600V** 3 0.8 60 1438 1214 1052 526 421 345/345 350/437 350/437 350/437 350/437 1000 850 737 368 295 240/240 245/306 245/306 245/306 245/306 700 573RSL4035 130 °C/40 °C 930 433CSL6216 130 °C/40 °C 930 433CSL6216 130 °C/40 °C 1238 433CSL6216 130 °C/40 °C 1100 433PSL6248 130 °C/40 °C 12 LEAD ZIG-ZAG 12 LEAD LOW WYE 12 LEAD HI DELTA 12 LEAD HI WYE 4 LEAD WYE * Consult the factory for alternate configuration. ** UL 2200 Offered CERTIFICATIONS AND STANDARDS // Generator set is designed and manufactured in facilities certified to standards ISO 9001:2008 and ISO 14001:2004 // UL 2200 / CSA – Optional – UL 2200 Listed – CSA Certified // Performance Assurance Certification (PAC) - Generator Set Tested to ISO 8528-5 for Transient Response - Verified product design, quality and performance integrity - All engine systems are prototype and factory tested // Power Rating - Accepts Rated Load in One Step Per NFPA 110 2 / // / MTU 10V0183 GS350 (350 kWe) - Standby STANDARD FEATURES* // // // // // // // // MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty 18.3 L Turbo Engine Charge Air Cooling - 18.3 Liter Displacement - 4-Cycle 3-Way Catalyst Optional Fuel System: NG and LP Vapor Dual Fuel Engine-generator resilient mounted Complete Range of Accessories Generator - Brushless, Rotating Field Generator - 2/3 Pitch Windings - 300% Short Circuit Capability with PMG ○ PMG Standard for 570 frame and larger ○ PMG Optional for 430 frame and smaller // Digital Control Panel(s) - UL Recognized, CSA Certified, NFPA 110 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan // STANDARD EQUIPMENT* // Engine Air Cleaner Oil Pump Oil Drain Extension & S/O Valve Full Flow Oil Filter Jacket Water Pump Thermostats Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electronic Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (with PMG only) Self Ventilated and Drip-proof Superior Voltage Waveform Solid State, Volts-per-hertz Regulator (Digital when PMG is Standard) ±1% Voltage Regulation No Load to Full Load Brushless Alternator with Brushless Pilot Exciter 4 pole, Rotating Field 130 °C Maximum Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-phase Voltage Sensing 100% of Rated Load - One Step 5% Maximum Total Harmonic Distortion // Digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows®-Based Software Multilingual Capability Remote Communications to RDP-110 Remote Annunciator Programmable Input and Output Contacts UL Recognized, CSA Certified, CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Compatible * Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional configurations. 3 / // / MTU 10V0183 GS350 (350 kWe) - Standby APPLICATION DATA // Engine Manufacturer Model Type Arrangement Displacement: L (in3) Bore: cm (in) Stroke: cm (in) Compression Ratio Rated RPM Engine Governor Maximum Power (NG): kWm (bhp) Maximum Power (LP): kWm (bhp) Speed Regulation Air Cleaner // // Doosan 18.3L CAC 4-Cycle 10-V 18.3 (1,115) 12.8 (5.04) 14.2 (5.59) 10.5:1 1,800 Bosch 400 (536) 297 (398) ±0.5% Dry NG LPG At 100% of Power Rating: m3/hr (ft3/hr) 99.1 (3,498.8) 32.5 (1,145.9) At 75% of Power Rating: m3/hr (ft3/hr) 77.2 (2,726.7) 27.7 (977.1) At 50% of Power Rating: m3/hr (ft3/hr) 54.2 (1,913.7) 18.7 (658.5) // Ambient Capacity of Radiator: °C (°F) Maximum Restriction of Cooling Air, Intake, and Discharge Side of Rad.: kPa (in. H20) Water Pump Capacity: L/min (gpm) Heat Rejection to Coolant: kW (BTUM) Heat Radiated to Ambient: kW (BTUM) Fan Power: kW (hp) NG and LPG 50 (122)* 0.12 (0.5) 660 (174) 365 (20,784) 88.5 (5,030) 20.9 (28) 42.1 (11.1) 50 (11) 289 (63.5) * Installation of enclosures reduces the ambient capacity of the cooling system by 1 °C (1.8 °F). Gravity exhaust louvers reduce ambient capacity of the cooling system by an additional 3 °C (5.5 °F). // Air Requirements Electrical Electric Volts DC Cold Cranking Amps Under -17.8°C (0 °F) // Cooling - Radiator System Liquid Capacity (Lubrication) Total Oil System: L (gal) Engine Jacket Water Capacity: L (gal) System Coolant Capacity: L (gal) // Fuel Consumption (NG-1000 BTU/ft3 / LP-2500 BTU/ft3) 24 1,050 Fuel Inlet Fuel Supply Connection Size Fuel Supply Pressure: mm H20 (in. H20) 3” NPT 178–279 (7–11) NG and LPG 19.4 (664) Aspirating: *m3/min (SCFM) Air Flow Required for Rad. Cooled Unit: **m3/min (SCFM) Remote Cooled Applications; Air Flow Required for Dissipation of Radiated Gen-set Heat for a Max of 25 °F Rise: *m3/min (SCFM) 1,019 (36,000) 321 (11,350) * Air density = 1.184 kg/m (0.0739 lbm/ft ) ** At 0.25 kPa (1 in. H20) static pressure and 52 °C (125 °F) at radiator 3 // 3 Exhaust System Gas Temp. (Stack): °C (°F) Gas Volume at Stack Temp: m3/min (CFM) Maximum Allowable Back Pressure: kPa (in. H20) NG and LPG 607 (1,125) 58.6 (2,070) 2.5 (10.25) 4 / // / MTU 10V0183 GS350 (350 kWe) - Standby WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Open Power Unit (OPU) Dimensions (L x W x H) 4,369 x 2,506 x 2,413 mm (172 x 98.63 x 95 in) Weight (dry) 4,741 kg (10,452 lb) SOUND DATA Unit Type Level 0: Open Power Unit dB(A) Standby Full Load (NG) 85.1 Standby Full Load (LP) 84.8 Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infinite exhaust. EMISSIONS DATA Fuel Type Natural Gas Liquid Propane THC + NOx 0.59 0.07 RATING DEFINITIONS AND CONDITIONS CO 0.21 0.15 All units are in g/hp-hr and are EPA weighted cycle values. Emission levels of the engine may vary with ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data was obtained in compliance with US EPA regulations. C/F = Consult Factory/MTU Onsite Energy Distributor N/A = Not Available MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 3046-1, BS 5514, and AS 2789. Average load factor: ≤ 85%. // Deration Factor: Production tolerances in engines and installed components can account for power variations. Altitude, temperature and excessive exhaust and intake restrictions should be applied to power calculations. Consult your local MTU Onsite Energy Power Generation Distributor for derations. // © MTU Onsite Energy. Subject to alteration due to technological advances. OE 23 480 (72 3E) 2015-03 Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.