DMS-20PC-1-LM-FC - Murata Power Solutions

DMS-20PC-1-LM
www.murata-ps.com
Self-Powered 3 Digit, LED Display
AC Line Voltage Monitors
FEATURES

Plugs directly into USA-style wall outlets

Screw terminals for panel mounting

Small 1.38" x 0.88" x 1.0" packages

Large, easy-to-read, red, blue or green LED displays

Fully encapsulated for harsh environments

Half-wave averaging, rms calibrated

UL, CSA and IEC1010-1 certified

Very low cost!
Murata Power Solution's DMS-20PC-1-LM is a component-size, self-contained, low-cost
ac voltmeter for true line measurements. It requires no additional components or auxiliary
power. Simply plug it into any wall outlet and instantly read voltages from 85 to 264Vac
(47-63Hz). The large (0.37"/9.4mm), bright red, blue or green LED display makes the
DMS-20PC-1-LM easily readable under any lighting conditions.
DMS-20PC-1-LM employs half-wave
DMS-20PC-1-LM-F
sinusoidal averaging (rms calibrated) and has
(Blade Terminals)
a display resolution of 1Vac over its full input
8C48
range. Packaged in a red-filter case with builtin bezel, the meter is fully encapsulated for
ruggedness. All units are overvoltage protected
to 300Vac.
This low-cost meter is ideal for industrial,
laboratory, office and field-service applications. Its miniature size is perfect for design
DMS-20PC-1-LM
into high-end consumer electronics, laboratory
(Panel Mount)
instrumentation and other products requiring
accurate ac line monitoring.
Suggested wiring (user supplied)
®
C
Functional Specifications
Input
Voltage Range ➀
UL/IEC61010-1
Frequency Range ➀
Current Consumption
85-264Vrms
Measurement Category II
47-63Hz
50mArms (max.)
®
US E156931
Ordering Information
Performance
Sampling Rate
Measurement Type
2.5 readings/second
Half-wave average, rms
calibrated for sinusoidal input
±1V (typ.), ±2V (max.)
Accuracy @ +25°C
Temperature Drift
(–25 to +60°C)
±0.15 Volts/°C (max.)
Mechanical
Dimensions
Display Type
Weight
Case Material
6-32 screw torque
1.38" x 0.88" x 1.00"
3 digit, red LED, 0.37"/9.4mm
1 ounce (28 grams)
Polycarbonate
6-8 in-lb (0.7 – 0.9N-m)
DMS-20PC-1-LM-C
DMS-20PC-1-LM-B-C
DMS-20PC-1-LM-G-C
DMS-20PC-1-LM-F-C
DMS-20PC-1-LM-BF-C
DMS-20PC-1-LM-GF-C
DMS-20-CP
DMS-BZL3-C
DMS-BZL4-C
Red LED with threaded standoffs ➁
Blue LED with threaded standoffs ➁
Green LED with threaded standoffs ➁
Red LED with blade terminals
Blue LED with blade terminals
Green LED with blade terminals
Optional panel cutout punch
Optional panel mount bezel
Optional panel mount bezel with sealing gasket
➁ Brass screws (6-32 thread) and a panel-mount retaining clip are supplied with meter.
Environmental
Operating Temperature
–25 to +60°C
Storage Temperature
–40 to +75°C
Humidity (Non-condensing)
0 to 95%
➀ Operation and accuracy at inputs above or below these ranges are not specified.
CURRENT
LIMITED
AC SUPPLY
For full details go to
www.murata-ps.com/rohs
Typical Connection Diagram
www.murata-ps.com/support
MPM_DMS-20PC-1-LM.C08 Page 1 of 2
DMS-20PC-1-LM
Self-Powered 3 Digit, LED Display
AC Line Voltage Monitors
Power Supply Polarity, Grounding, Fusing, and Wiring
1. Polarity and Grounding:
DMS-20PC-1-LM’s two ac-supply input terminals are not polarity sensitive,
that is, they have no “AC LO” or “AC HI” designations. These units do not
include nor require a connection to earth/chassis ground. All ac-supply wiring
must be rated for the voltages and currents they will conduct and comply
with any code or application-mandated requirements pertaining to the user’s
specific installation. Additional model-specific information is provided below.
3. UL Listed Models with “Plug-in” Blade Terminals:
2. UL Recognized Panel Mount Models with Screw Terminals:
4. Description of the safety marks:
Caution, risk of electrical shock
C
®
Plug-in DMS-20PC-1-LM-XF models are not internally fused and must be
protected by an external current limiting circuit breaker or fuse in accordance
with applicable regulatory codes. These models are designed to be plugged
into NEMA 1-15R, NEMA 5-15R, and NEMA 5-20R receptacles.
US E156931
DMS-20PC-1-LM AC voltmeters are not internally fused. The supply wires
feeding these voltmeters must be fused with a 0.25A/250V time delay/time lag
fuse, in accordance with applicable regulatory codes. The rear threaded standoff input-terminals are to be used only for powering the voltmeter’s internal
circuitry; they must not be used to supply power to external loads.
The recommended wire size is 16AWG to 20AWG (1.31mm2 to 0.52mm2)
stranded copper wire. Wires must be properly stripped and attached to the
threaded standoffs such that their insulation is not pinched by the supplied
6-32 screws. Rated tightening torque for the 6-32 screws is 7 to 8 poundinches (0.8 to 0.9N-m). 300V UL rated wire suitable for the intended application is required.
Caution, risk of danger
Equipment is protected throughout by double or reinforced insulation
5. Cleaning Instructions: Gently clean with dry cloth only.
6. Caution: if the equipment is used in a manner not specified by Murata
Power Solutions, the protection provided by the equipment may be
impaired.
1.30
(33.0)
DMS-20PC-1-LM
®
®
0.04
(1.016)
0.04
(1.016)
#6-32
UNC THD
0.44
(11.2)
0.75
(19.1)
0.80
(20.3)
0.32
(8.1)
0.88
(22.4)
ISO 9001 and 14001 REGISTERED
1.38
(35.1)
0.37
(9.4)
1.00
(25.4)
#2-56 INSERT
0.156 (3.96) DEEP
1.07
(27.2)
DMS-BZL3-C
Optional Bezel
0.10
(2.5)
1.63 (41.4)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
0.04
(1.016)
0.19
(4.8)
1.28
(32.5)
0.10
(2.5)
Dimensions in inches (millimeters)
Tolerances: 2 PL Dec ±0.02 (±0.51)
3 PL Dec ±0.010 (±0.254)
Recommended panel cutout dimensions:
1.336 (33.93)W × 0.838 (21.29)H
Internal corner radii 0.032 (0.81) Max.
1.83 (46.5)
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
MPM_DMS-20PC-1-LM.C08 Page 2 of 2