IgG (Protein A based) Detection Kit

TECHNICAL
DATA
SHEET
AlphaScreen® Research Reagents
Caution: For Laboratory Use. A research reagent for research purposes only
IgG (Protein A based) Detection Kit
Product No.: 6760617M
Lot No.: 1890679
Material Provided
Format:
6760617C
6760617M
6760617R
500 Assay Points
10000 Assay Points
50000 Assay Points
Note: The number of assay points is based on a final bead concentration of 20 µg/mL
in a 25 µL/well reaction volume.
Manufacturing Date:
th
May 5 , 2014
Kit Components:
Component
Protein A Acceptor Beads at 5 mg/mL in 0.1M
Tris, 0.05% Proclin-300, pH 8.0
Streptavidin Donor Beads at 5 mg/mL in 0.1M
Tris, 0.05% Proclin-300, pH 8.0
Biotinylated-rIgG at 0.05 µM in 1X PBS, 0.1%
BSA, 0.05% Proclin-300, pH 7.2
10x Buffer : 1M Tris, 0.1% Tween-20, 0.05%
Proclin-300, pH 8.0
6760617C
1 x 50 µL
6760617M
1 x 1 mL
6760617R
1 x 5 mL
(6760137B)
(6760136)
(6760137)
1 x 50 µL
1 x 1 mL
1 x 5 mL
(6760007)
(6760008)
(6760008B)
1 x 50 µL
1 x 50 µL
1 x 50 µL
(6760264)
(6760264)
(6760264)
1 x 1.5 mL
1 x 1.5 mL
1 x 1.5 mL
(6760028G)
(6760028G)
(6760028G)
Product Information
Antibody/Protein:
The Protein A acceptor beads are coated with Protein A. Protein A binds the Fc
region of many IgG.
Stability:
This product is stable for at least 9 months from the manufacturing date if used and
stored under recommended conditions.
Storage Conditions:
Store undiluted at 4°C protected from light. Freeze-thaw is not recommended and
can cause the beads to form aggregates.
Recommended use:
AlphaScreen® Donor beads are light-sensitive. All Alpha assays using the Donor
beads should be performed under subdued laboratory lighting (< 100 lux). Green
filters (LEE 090 filters (preferred) or Roscolux filters #389 from Rosco) can be
applied to light fixtures.
®
For additional information on running AlphaScreen assays or on potential interfering compounds, please visit our
website: www.perkinelmer.com/AlphaTech
TDS-6760617C/M/R-02
Page 1 of 3
Quality Control
®
AlphaScreen maximum signal, minimum signal and EC50 are determined using a biotinylated-rIgG titration assay
®
performed on an EnVision HTS Alpha detection instrument. We certify that these results meet our requirements.
TEST
RESULTS
Maximum signal
Minimum signal
EC50
809903 cps
1170 cps
0.10 nM
Recommended Assay Conditions
Note: This protocol provides a method to verify kit performance and is not representative of an assay. Sufficient
biotinylated-probe and 10x buffer is provided to perform 3 titration curves in triplicate as described.
®
1x Buffer:
Add 500 μL 10x buffer to 4.5 mL Milli-Q H2O (or equivalent). Add 5 mg BSA (0.1%
final concentration) and adjust pH to 8.0.
Acceptor Beads:
Add 5 μL Protein A Acceptor beads to 245 μL 1x buffer.
Donor beads:
Add 5 μL Streptavidin Donor beads to 245 μL 1x buffer.
Biotinylated-probe:
From the 0.05 µM biotinylated-rIgG, prepare a ½ log dilution series (15 nM to 1.5
pM) in 1x buffer. Include a buffer only control.
Titration Protocol:
To a white opaque 384-well Optiplate:
1-
Add 5 μL biotinylated-rIgG dilutions (from lowest to highest concentration).
2-
Add 10 μL of 1x buffer
3-
Add 5 μL of Protein A Acceptor beads.
Incubate in the dark at room temperature for 30 minutes.
4-
Add 5 μL of Streptavidin Donor beads.
®
Incubate in the dark at room temperature for 60 minutes and analyze on your AlphaScreen detection
reader.
TDS-6760617C/M/R-02
Page 2 of 3
AlphaScreen signal (counts)
Product Typical Data
900000
750000
600000
450000
300000
150000
0
-
-13
-12
-11
-10
-9
-8
log [b-rIgG] (M)
Figure 1: Biotinylated-probe titration assay
384-well biotinylated-rIgG titration curve (25 μL final
volume; Reader: Envision HTS Alpha).
Note: AlphaScreen signal will vary depending on
instrument detection protocol, incubation temperature
and incubation time.
Suggested Materials and Instrumentation
Please visit our website
www.perkinelmer.com/AlphaTech
This product is not for resale or distribution except by authorized distributors.
LIMITED WARRANTY: PerkinElmer BioSignal Inc. warrants that, at the time of shipment, the products sold by it are free from defects in material and workmanship
and conform to specifications which accompany the product. PerkinElmer BioSignal Inc. makes no other warranty, express or implied with respect to the products,
including any warranty of merchantability or fitness for any particular purpose. Notification of any breach of warranty must be made within 60 days of receipt unless
otherwise provided in writing by PerkinElmer BioSignal Inc. No claim shall be honored if the customer fails to notify PerkinElmer BioSignal Inc. within the period
specified. The sole and exclusive remedy of the customer for any liability of PerkinElmer BioSignal Inc. of any kind including liability based upon warranty (express or
implied whether contained herein or elsewhere), strict liability contract or otherwise is limited to the replacement of the goods or the refunds of the invoice price of
goods. PerkinElmer BioSignal Inc. shall not in any case be liable for special, incidental or consequential damages of any kind.
PerkinElmer, Inc.
940 Winter Street
Waltham, MA 02451 USA
P: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs
Copyright ©2009, PerkinElmer, Inc. All rights reserved. PerkinElmer ® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.