canec0900011002

Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Page 1 of 7
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
NO.4 HUANGGUSHAN ROAD,HANGZHOU,ZHEJIANG
CHINA
The following sample(s) was/were submitted and identified on behalf of the clients as :
(L)QFP176
SGS Job No.
SGS Internal Reference No.
Client Reference Information
Date of Sample Received
Testing Period
:
:
:
:
:
11527428 - GZ
4.2
SC8390/SC8632A/SC8633A/SC8636A
04 Jan 2009
04 Jan 2009 - 08 Jan 2009
Test Requested
:
Selected test(s) as requested by client.
Test Method
:
Please refer to next page(s).
Test Results
:
Please refer to next page(s).
Conclusion
:
A: Based on the performed tests on submitted sample(s), the results comply
with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of
SGS-CSTC Ltd.
Huang Fang, Sunny
Sr. Engineer
Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Page 2 of 7
Test Results:
ID for specimen 1
Description for specimen 1
: CAN09-000110.003
: Black body w/ brown printing (mixed)
A: RoHS Directive 2002/95/EC
Test Item(s)
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (CrVI) by
alkaline extraction
Sum of PBBs
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs
Monobromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether ##
Unit
mg/kg
mg/kg
mg/kg
mg/kg
Test Method (Reference)
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
IEC 62321/2nd CDV (111/95/CDV), UV-Vis
Result
N.D.
N.D.
N.D.
N.D.
MDL
2
2
2
2
Limit
100
1000
1000
1000
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
IEC 62321/2nd CDV (111/95/CDV), GC-MS
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
1000
1000
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the
European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE will be included in the sum of
PBDE after 01.07.2008
5. "-" = Not regulated
Test Report
No. CANEC0900011002
ID for specimen 2
Description for specimen 2
Date: 09 Jan 2009
Page 3 of 7
: CAN09-000110.004
: Silvery plated metal pin
A: RoHS Directive 2002/95/EC
Test Item(s)
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (CrVI) by
boiling water extraction
Unit
mg/kg
mg/kg
mg/kg
-
Test Method (Reference)
Result
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
N.D.
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
N.D.
IEC 62321/2nd CDV (111/95/CDV), ICP-OES
N.D.
IEC 62321/2nd CDV (111/95/CDV), UV-Vis Negative
MDL
2
2
2
♢
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ◇ = Spot-Test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result
is negative or cannot be confirmed.)
Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is
equal or greater than 0.02 mg/kg with 50 cm² sample surface area.
5. # = Positive indicates the presence of CrVI on the tested areas.
Negative indicates the absence of CrVI on the tested areas.
6. "-" = Not regulated
B: Heavy metal(s)
Test Item(s)
Hexavalent Chromium (CrVI) by
boiling water extraction
Unit
μg/cm²
Test Method (Reference)
JIS H8625-1993, UV-Vis
Result
N.D.
MDL
0.02
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
Remark: As requested by client, the testing of specimen 1 was conducted as whole / part sample, for the
sample can’t be disjointed.
Limit
100
1000
1000
#
Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Page 4 of 7
Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Page 5 of 7
Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Page 6 of 7
Test Report
No. CANEC0900011002
Date: 09 Jan 2009
Sample photo:
CANEC0900011002
CAN09-000110.003
CANEC0900011002
CAN09-000110.004
SGS authenticate the photo on original report only
*** End of Report ***
Page 7 of 7